Transcatheter closure or secundum atrial septal defects with the Amplatzer septal occluder: Early experience

被引:0
|
作者
Matitiau, A
Birk, E
Kachko, L
Blieden, LC
Bruckheimer, E
机构
[1] Schneider Childrens Med Ctr Israel, Pediat Cardiol Sect, IL-49292 Petah Tiqwa, Israel
[2] Kaplan Med Ctr, Rehovot, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2001年 / 3卷 / 01期
关键词
congenital heart defect; atrial septal defect; Amplatzer septal occluder; interventional catheterization; transcatheter closure;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Secundum atrial septal defect is a common congenital heart defect that causes right heart volume overload and produces symptoms usually after the third decade of life. Treatment until the last few years has been open heart surgery. Objectives: To review our early experience with transcatheter closure of ASD2 using the Amplatzer septal occluder. Methods: Between November 1999 and February 2000, 20 children and young adults with a median age of 9.1 years (4.2-35.1 years) were referred for transcatheter closure of ASD2. Diagnosis was established by transthoracic echocardiography. Implantation was performed under general anesthesia through the femoral vein with the guidance of transesophageal echocardiography and fluoroscopy. Femoral arterial puncture was performed for blood pressure monitoring during the procedure, The device size chosen was similar to the balloon-stretched diameter of the ASD2. Results: Implantation was completed successfully in 18 patients. Two patients were referred for elective surgery: one had an unsuitable anatomy for transcatheter closure by TEE in the catheterization laboratory and the device could not be implanted properly, the other patient had a large multi-perforated septal aneurysm that was retrieved. Mean ASD2 diameter by TTE and TEE was similar (13.9 +/- 3 mm, 13.4 +/- 3.5 mm) and mean stretched diameter was 18.3 +/- 4.3 mm. Mean Op:Qs (pulmonary flow:systemic flow) was 2.2 +/- 0.6. Mean fluoroscopy time for the procedure was 14.8 +/- 4.8 minutes. The patients were discharged the day after the procedure. Four patients had a tiny leak immediately post-procedure, and none had a leak at one month follow-up. The only complication was a small pseudoaneurysm of the femoral artery in one patient, that resolved spontaneously. Conclusions: Transcatheter closure of ASD2 with the Amplatzer septal occluder is a safe and effective alternative to surgical closure. Long-term outcome has to be evaluated.
引用
收藏
页码:32 / 35
页数:4
相关论文
共 50 条
  • [1] TRANSCATHETER CLOSURE OF LARGE SECUNDUM ATRIAL SEPTAL DEFECTS WITH AMPLATZER SEPTAL OCCLUDER
    杨震坤
    Aubry Pierre
    Eric Brochet
    Jean-Michel Juliard
    Medical Bulletin of Shanghai Jiaotong University, 2010, 22 (01) : 40 - 46
  • [2] Simultaneous transcatheter closure of two secundum atrial septal defects using the Amplatzer™ septal occluder
    Hijazi, ZM
    Bova, S
    Rhodes, J
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1998, 11 (03) : 181 - 184
  • [3] Transcatheter closure of secundum atrial septal defects in adult patients using the amplatzer septal occluder
    Hijazi, ZM
    Cao, OL
    Joseph, A
    Du, ZD
    Heitschmidt, M
    Waight, DJ
    Koenig, P
    Patel, H
    Rhodes, J
    CIRCULATION, 2002, 106 (19) : 620 - 620
  • [4] The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder
    Mazic, U
    Gavora, P
    Masura, J
    AMERICAN HEART JOURNAL, 2001, 142 (03) : 482 - 488
  • [5] Transcatheter closure of secundum atrial septal defect using an Amplatzer septal occluder
    Kong, XQ
    Cao, KJ
    Yang, R
    Xu, D
    Sheng, YH
    Huang, J
    Ma, WZ
    CHINESE MEDICAL JOURNAL, 2002, 115 (01) : 126 - 128
  • [6] A multicentre, comparative study of Cera septal occluder versus AMPLATZER Septal Occluder in transcatheter closure of secundum atrial septal defects
    Kaya, Mehmet Gungor
    Akpek, Mahmut
    Celebi, Ahmet
    Saritas, Turkay
    Meric, Murat
    Soylu, Korhan
    Karapinar, Hekim
    Lam, Yat-Yin
    EUROINTERVENTION, 2014, 10 (05) : 626 - 631
  • [7] Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer Septal Occluder
    Fischer, G
    Kramer, HH
    Stieh, J
    Harding, P
    Jung, O
    EUROPEAN HEART JOURNAL, 1999, 20 (07) : 541 - 549
  • [8] Closure of secundum atrial septal defects by the Amplatzer occluder device
    Yuce, Murat
    Ozer, Orhan
    Cakici, Musa
    Sari, Ibrahim
    Davutoglu, Vedat
    Dogan, Adnan
    Alici, Hayri
    Yavuz, Fethi
    Aksoy, Mehmet
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2011, 39 (01): : 35 - 40
  • [9] Transcatheter closure of atrial septal defects in adults with the amplatzer septal occluder
    Dhillon, R
    Thanopoulos, B
    Triposkladis, F
    Tsaousis, G
    Kyriakidis, M
    Redington, A
    CIRCULATION, 1998, 98 (17) : 619 - 619
  • [10] Transcatheter closure of atrial septal defects in adults with the Amplatzer septal occluder
    Dhillon, R
    Thanopoulos, B
    Tsaousis, G
    Triposkiadis, F
    Kyriakidis, M
    Redington, A
    HEART, 1999, 82 (05) : 559 - 562