Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly

被引:6
|
作者
Neumann, Katja [1 ]
Schidlowski, Martin [2 ,3 ]
Guenther, Matthias [4 ,5 ]
Stoecker, Tony [2 ,6 ]
Duezel, Emrah [1 ,7 ,8 ,9 ]
机构
[1] German Ctr Neurodegenerat Dis DZNE, Magdeburg, Germany
[2] German Ctr Neurodegenerat Dis DZNE, Bonn, Germany
[3] Univ Bonn, Dept Epileptol, Med Ctr, Bonn, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[5] Univ Bremen, MR Imaging & Spect, Bremen, Germany
[6] Univ Bonn, Dept Phys & Astron, Bonn, Germany
[7] Otto von Guericke Univ, Inst Cognit Neurol & Dementia Res, Magdeburg, Germany
[8] UCL, Inst Cognit Neurosci, London, England
[9] Ctr Behav Brain Sci, Magdeburg, Germany
关键词
arterial spin labeling; pCASL; reliability; reproducibility; perfusion; cerebral blood flow; arterial transit time; hadamard encoding; CEREBRAL-BLOOD-FLOW; BOLUS ARRIVAL-TIME; INVERSION; MRI; INFERENCE; MODEL; AGE;
D O I
10.3389/fnins.2021.711898
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The perfusion parameters cerebral blood flow (CBF) and arterial transit time (ATT) measured with arterial spin labeling (ASL) magnetic resonance imaging (MRI) provide valuable essentials to assess the integrity of cerebral tissue. Brain perfusion changes, due to aging, an intervention, or neurodegenerative diseases for example, could be investigated in longitudinal ASL studies with reliable ASL sequences. Generally, pseudo-continuous ASL (pCASL) is preferred because of its larger signal-to-noise ratio (SNR) compared to pulsed ASL (PASL) techniques. Available pCASL versions differ regarding their feature details. To date only little is known about the reliability and reproducibility of CBF and ATT measures obtained with the innovative Hadamard encoded pCASL variant, especially if applied on participants in old age. Therefore, we investigated an in-house developed Hadamard encoded pCASL sequence on a group of healthy elderly at two different 3 Tesla Siemens MRI systems (Skyra and mMR Biograph) and evaluated CBF and ATT reliability and reproducibility for several regions-of-interests (ROI). Calculated within-subject coefficients of variation (wsCV) demonstrated an excellent reliability of perfusion measures, whereas ATT appeared to be even more reliable than CBF [e.g., wsCV(CBF) = 2.9% vs. wsCV(ATT) = 2.3% for a gray matter (GM) ROI on Skyra system]. Additionally, a substantial agreement of perfusion values acquired on both MRI systems with an inter-session interval of 78 +/- 17.6 days was shown by high corresponding intra-class correlation (ICC) coefficients [e.g., ICC(CBF) = 0.704 and ICC(ATT) = 0.754 for a GM ROI]. The usability of this novel Hadamard encoded pCASL sequence might improve future follow-up perfusion studies of the aging and/or diseased brain.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Test-Retest Reproducibility of Cerebral Blood Flow Measurements Using Pseudo-continuous Arterial Spin labeling at 1.5T
    Sohn, Chul-ho
    Kim, Ji-Hoon
    Choi, Seung Hong
    Han, Moon Hee
    Chang, Kee-Hyun
    Song, In-chan
    Jahng, Geon-Ho
    Yun, Tae-Jin
    STROKE, 2011, 42 (03) : E287 - E287
  • [32] Volumetric measurement of perfusion and arterial transit delay using hadamard encoded continuous arterial spin labeling
    Dai, Weiying
    Shankaranarayanan, Ajit
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1014 - 1022
  • [33] Neural plasticity secondary to carpal tunnel syndrome: a pseudo-continuous arterial spin labeling study
    Deng, Xue
    Chau, Phoebe Lai-Heung
    Chiu, Suk-Yee
    Leung, Kwok-Pui
    Hu, Yong
    Ip, Wing-Yuk
    NEURAL REGENERATION RESEARCH, 2021, 16 (01) : 158 - 165
  • [34] Cerebral perfusion alterations in patients with trigeminal neuralgia as measured by pseudo-continuous arterial spin labeling
    Zhou, Qianling
    Li, Meng
    Fan, Qisen
    Chen, Feng
    Jiang, Guihua
    Wang, Tianyue
    He, Qinmeng
    Fu, Shishun
    Yin, Yi
    Lin, Jinzhi
    Yan, Jianhao
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [35] HEART VESSELS - Pseudo-continuous arterial Spin Labeling detects Splenic Switch-Off
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (04): : 339 - 340
  • [36] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [37] Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla
    Sigurdsson, Sigurdur
    Forsberg, Lars
    Aspelund, Thor
    van der Geest, Rob J.
    van Buchem, Mark A.
    Launer, Lenore J.
    Gudnason, Vilmundur
    van Osch, Matthias J.
    PLOS ONE, 2015, 10 (12):
  • [38] Model-based super-resolution reconstruction for pseudo-continuous Arterial Spin Labeling
    Beirinckx, Quinten
    Bladt, Piet
    van der Plas, Merlijn C. E.
    van Osch, Matthias J. P.
    Jeurissen, Ben
    den Dekker, Arnold J.
    Sijbers, Jan
    NEUROIMAGE, 2024, 286
  • [39] Effect of background suppression and motion correction on pseudo-continuous arterial spin labeling CBF measurement
    Ibaraki, M.
    Nakamura, K.
    Toyoshima, H.
    Takahashi, K.
    Matsubara, K.
    Pfeuffer, J.
    Kuribayashi, H.
    Kinoshita, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 359 - 360
  • [40] Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    Silva, AC
    Kim, SG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 425 - 429