Evaluation of indoor/outdoor urban air pollution by magnetic, chemical and microscopic studies

被引:28
|
作者
Jelenska, M. [1 ]
Gorka-Kostrubiec, B. [1 ]
Werner, T. [1 ]
Kadzialko-Hofmokl, M. [1 ]
Szczepaniak-Wnuk, I. [1 ]
Gonet, T. [2 ]
Szwarczewski, P. [3 ]
机构
[1] Polish Acad Sci, Inst Geophys, Ks Janusza 64, PL-01452 Warsaw, Poland
[2] Univ Warsaw, Fac Geol, Zwirki I Wigury 93, PL-02089 Warsaw, Poland
[3] Univ Warsaw, Fac Geog & Reg Studies, Krakowskie Przedmiescie 30, PL-00927 Warsaw, Poland
关键词
Outdoor pollution; Indoor pollution; Magnetic method; SEM; Heavy metals; ATMOSPHERIC PARTICULATE MATTER; INDOOR DUST; PARTICLES; SUSCEPTIBILITY; SIGNATURE; QUALITY; SIZE; PM10;
D O I
10.1016/j.apr.2017.01.006
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The paper presents comparison of outdoor and indoor air pollution by means of magnetic characteristics of dust settled on the floor indoors (ID) and particulate matter (PM) gathered outdoor on air filters. Samples were collected for one year period in three different locations in Warsaw, Poland. PM was collected in samplers placed at the yard of buildings and ID was collected inside these buildings using a vacuum cleaner. The magnetic methods supplemented by chemical elements analysis and microscope observations were applied to identification of magnetic mineralogy, concentration and grain-size of magnetic fraction and morphology and shape of particles. The results demonstrated differences in magnetic mineralogy and in grain-size distribution between PM and ID. The magnetite was the main magnetic phase in PM and magnetite with metallic iron in ID. The ratios of hysteresis parameters for PM and ID were located in different areas on Day-Dunlop diagram; PM data in the area for PSD magnetite and fine SP grains and ID data around SD + MD mixing curves for magnetite. The difference in magnetic mineralogy, especially the lack of metallic iron in PM, can be explained by the limitation of dust samplers that cannot collect grains larger than roughly 50 mm due to our microscopic observations. PM samplers collect population of dust with smaller grain size than vacuum cleaner or simple sweeping of a floor. The difference in granulometry and outdoor/indoor sources could be one of the reasons for which we did not observed the simple relation between magnetic susceptibility of ID and PM. (C) 2017 Turkish National Committee for Air Pollution Research and Control. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 766
页数:13
相关论文
共 50 条
  • [1] Evaluation of indoor/outdoor urban air pollution by magnetic parameters; preliminary study
    Jelenska, M.
    Werner, T.
    Kadzialko-Hofmokl, M.
    Karasinski, G.
    [J]. JOURNAL OF APPLIED GEOPHYSICS, 2022, 206
  • [2] Indoor cooking and cleaning as a source of outdoor air pollution in urban environments
    Carter, Toby J.
    Shaw, David R.
    Carslaw, David C.
    Carslaw, Nicola
    [J]. ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2024, 26 (06)
  • [3] Outdoor-indoor air pollution in urban environment: challenges and opportunity
    Leung, Dennis Y. C.
    [J]. FRONTIERS IN ENVIRONMENTAL SCIENCE, 2015, 2
  • [4] Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran
    Mahmoud Mohammadyan
    Mahboobeh Ghoochani
    Itai Kloog
    Sabah Ahmed Abdul-Wahab
    Kaan Yetilmezsoy
    Behzad Heibati
    Krystal J. Godri Pollitt
    [J]. Environmental Monitoring and Assessment, 2017, 189
  • [5] Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran
    Mohammadyan, Mahmoud
    Ghoochani, Mahboobeh
    Kloog, Itai
    Abdul-Wahab, Sabah Ahmed
    Yetilmezsoy, Kaan
    Heibati, Behzad
    Pollitt, Krystal J. Godri
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2017, 189 (05)
  • [6] Studies on Biosmotrap: A multipurpose biological air purifier to minimize indoor and outdoor air pollution
    Yewale, Priti
    Wagle, Neeta
    Lenka, Shaurya
    Bannigol, Pramila
    Junnarkar, Manisha
    Prakash, Divya
    Abul Mandal
    Stigh, Cecilia
    Sahasrabudhe, Tushar
    Vannalwar, Tejas
    Thakare, Prasad
    Nikam, Dhiraj
    Pawar, Sarika
    Nawani, Neelu
    [J]. JOURNAL OF CLEANER PRODUCTION, 2022, 357
  • [7] Assessment of outdoor chemical and microbial pollution on global indoor air quality in hospitals
    Basilico, S
    Rubino, FM
    Bernazzani, G
    Bocchi, G
    Fasani, AM
    Colombi, A
    Ronchin, M
    Occhipinti, E
    [J]. VENTILATION AND INDOOR AIR QUALITY IN HOSPITALS, 1996, 11 : 181 - 189
  • [8] Indoor and outdoor air pollution and childhood asthma
    von Mutius, E
    [J]. PEDIATRIC PULMONOLOGY, 1997, : 86 - 87
  • [9] INDOOR AND OUTDOOR AIR-POLLUTION IN THE HIMALAYAS
    DAVIDSON, CI
    LIN, SF
    OSBORN, JF
    PANDEY, MR
    RASMUSSEN, RA
    KHALIL, MAK
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (06) : 561 - 567
  • [10] MICROORGANISMS AS INDOOR AND OUTDOOR AIR BIOLOGICAL POLLUTION
    Siebielec, Sylwia
    Wozniak, Malgorzata
    Galazka, Anna
    Siebielec, Grzegorz
    [J]. ADVANCEMENTS OF MICROBIOLOGY, 2020, 59 (02) : 115 - 127