Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran

被引:18
|
作者
Mohammadyan, Mahmoud [1 ]
Ghoochani, Mahboobeh [2 ]
Kloog, Itai [3 ]
Abdul-Wahab, Sabah Ahmed [4 ]
Yetilmezsoy, Kaan [5 ]
Heibati, Behzad [6 ]
Pollitt, Krystal J. Godri [7 ]
机构
[1] Mazandaran Univ Med Sci, Hlth Sci Res Ctr, Fac Hlth, Sari, Mazandaran, Iran
[2] Univ Tehran Med Sci, Dept Environm Hlth Engn, Fac Publ Hlth, Tehran, Iran
[3] Harvard Univ, Dept Environm Hlth, 665 Huntington Ave,Landmark Ctr Room 415, Boston, MA USA
[4] Sultan Qaboos Univ, Dept Mech & Ind Engn, Coll Engn, POB 33, Muscat 123, Oman
[5] Yildiz Tech Univ, Dept Environm Engn, Fac Civil Engn, TR-34200 Istanbul, Turkey
[6] Mazandaran Univ Med Sci, Hlth Sci Res Ctr, Fac Hlth, Student Res Comm, Sari, Mazandaran, Iran
[7] Univ Massachusetts, Dept Environm Hlth Sci, Sch Publ Hlth & Hlth Sci, Amherst, MA 01003 USA
关键词
Indoorairquality; PM1.0; PM2.5; PM10; Iran; PERSONAL EXPOSURE; RESPIRATORY-DISEASES; MORTALITY; PM10; PM2.5; ASSOCIATION; HEALTH; COHORT; FINE; SYMPTOMS;
D O I
10.1007/s10661-017-5951-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The relationship between indoor and outdoor particulate air pollution was investigated at an urban background site on the Payambar Azam Campus of Mazandaran University of Medical Sciences in Sari, Northern Iran. The concentration of particulate matter sized with a diameter less than 1 mu m (PM1.0), 2.5 mu m (PM2.5), and 10 mu m (PM10) was evaluated at 5 outdoor and 12 indoor locations. Indoor sites included classrooms, corridors, and office sites in four university buildings. Outdoor PM concentrations were characterized at five locations around the university campus. Indoor and outdoor PM measurements (1-min resolution) were conducted in parallel during weekday mornings and afternoons. No difference found between indoor PM10 (50.1 +/- 32.1 mu g/m(3)) and outdoor PM10 concentrations (46.5 +/- 26.0 mu g/m(3)), indoor PM2.5 (22.6 +/- 17.4 mu g/m(3)) and outdoor PM2.5 concentration (22.2 +/- 15.4 mu g/m(3)), or indoor PM1.0 (14.5 +/- 13.4 mu g/m(3)) and outdoor mean PM1.0 concentrations (14.2 +/- 12.3 mu g/m(3)). Despite these similar concentrations, no correlations were found between outdoor and indoor PM levels. The present findings are not only of importance for the potential health effects of particulate air pollution on people who spend their daytime over a period of several hours in closed and confined spaces located at a university campus but also can inform regulatory about the improvement of indoor air quality, especially in developing countries.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Assessment of indoor and outdoor particulate air pollution at an urban background site in Iran
    Mahmoud Mohammadyan
    Mahboobeh Ghoochani
    Itai Kloog
    Sabah Ahmed Abdul-Wahab
    Kaan Yetilmezsoy
    Behzad Heibati
    Krystal J. Godri Pollitt
    [J]. Environmental Monitoring and Assessment, 2017, 189
  • [2] Assessment of Indoor-Outdoor Particulate Matter Air Pollution: A Review
    Bo, Matteo
    Salizzoni, Pietro
    Clerico, Marina
    Buccolieri, Riccardo
    [J]. ATMOSPHERE, 2017, 8 (08)
  • [3] INDOOR/OUTDOOR CORRELATIONS REGARDING INDOOR AIR POLLUTION WITH PARTICULATE MATTER
    Bucur, Elena
    Danet, Andrei
    [J]. ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2019, 18 (02): : 425 - 432
  • [4] Particulate Air Pollution at Schools: Indoor-Outdoor Relationship and Determinants of Indoor Concentrations
    Mohammadyan, Mahmoud
    Alizadeh-Larimi, Ahmad
    Etemadinejad, Siavash
    Latif, Mohd Talib
    Heibati, Behzad
    Yetilmezsoy, Kaan
    Abdul-Wahab, Sabah Ahmed
    Dadvand, Payam
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (03) : 857 - 864
  • [5] Characteristics of indoor/outdoor particulate pollution in urban and rural residential environment of Pakistan
    Colbeck, I.
    Nasir, Z. A.
    Ali, Z.
    [J]. INDOOR AIR, 2010, 20 (01) : 40 - 51
  • [6] Outdoor particulate air pollution and indoor renovation associated with childhood pneumonia in China
    Jiang, Wei
    Lu, Chan
    Miao, Yufeng
    Xiang, Yuguang
    Chen, Lv
    Deng, Qihong
    [J]. ATMOSPHERIC ENVIRONMENT, 2018, 174 : 76 - 81
  • [7] Indoor cooking and cleaning as a source of outdoor air pollution in urban environments
    Carter, Toby J.
    Shaw, David R.
    Carslaw, David C.
    Carslaw, Nicola
    [J]. ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2024, 26 (06) : 975 - 990
  • [8] Outdoor-indoor air pollution in urban environment: challenges and opportunity
    Leung, Dennis Y. C.
    [J]. FRONTIERS IN ENVIRONMENTAL SCIENCE, 2015, 2
  • [9] Assessment of Indoor/outdoor Particulate Matter in Residential Building: Tehran Metropolis, Iran
    Oroji, Balal
    [J]. GEOFISICA INTERNACIONAL, 2023, 62 (03): : 581 - 590
  • [10] Outdoor and indoor respirable air particulate concentrations in differing urban traffic microenvironments
    O'Connell, Susan
    Au-Yeung, Ho-Kong C.
    Gregory, Clive J.
    Matthews, Ian P.
    [J]. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2008, 71 (16): : 1069 - 1072