Modified TID controller for load frequency control of a two-area interconnected diverse-unit power system

被引:81
|
作者
Ahmed, Mohamed [1 ]
Magdy, Gaber [2 ]
Khamies, Mohamed [3 ]
Kamel, Salah [3 ]
机构
[1] Sohag Univ, Fac Engn, Dept Elect Engn, Sohag 82524, Egypt
[2] Aswan Univ, Fac Energy Engn, Dept Elect Engn, Aswan 81528, Egypt
[3] Aswan Univ, Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
关键词
Load frequency control (LFC); Tilted integral derivative (TID); Integral derivative-tilted (ID-T); Archimedes optimization algorithm (AOA); Renewable energy sources (RESs); AUTOMATIC-GENERATION CONTROL; DERIVATIVE CONTROLLER; STABILITY; DESIGN; AGC; STRATEGY; TCSC;
D O I
10.1016/j.ijepes.2021.107528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, a modified structure of the tilted integral derivative (TID) controller, i.e. an integral derivativetilted (ID-T) controller, is developed for the load frequency control issue of a multi-area interconnected multisource power system. Moreover, a new optimization algorithm known as Archimedes optimization algorithm (AOA) is used to fine-tune the proposed ID-T controller parameters. The performance of the proposed ID-T controller based on AOA is evaluated through a two-area interconnected power system, each area containing various conventional generation units (i.e., thermal, gas, and hydraulic power plants) and renewables (wind and solar power). Furthermore, system nonlinearities (i.e., generation rate constraints, governor deadband, and communication time delays), system uncertainties, and load/renewables fluctuations are considered in designing the proposed controller. The effectiveness of the proposed ID-T controller based on AOA is verified by comparing its performance with other control techniques in the literature (i.e. integral controller, proportional integral derivative (PID) controller, fractional-order PID controller, TID controller, and I-TD controller). The AOA's optimization superiority has also been verified against a variety of other sophisticated optimization methods, including particle swarm optimization and whale optimization algorithm. The simulation results exhibit that the proposed ID-T controller based on the AOA presents a great improvement in the system frequency stability under several contingencies of different load perturbations, system uncertainties, physical constraints, communication time delays, high renewables penetration.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Communication time delay estimation for load frequency control in two-area power system
    Singh, Vijay P.
    Kishor, Nand
    Samuel, Paulson
    AD HOC NETWORKS, 2016, 41 : 69 - 85
  • [32] Two-Area AGC in Interconnected System Under the Restructured Power System Using BFO Controller
    Gupta, S. K.
    Arya, Yogendra
    Shukla, Shivank
    Chawla, Pankaj
    2014 6TH IEEE POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2014,
  • [33] Effects on Load-Frequency Control of a Solar Power System with a Two-Area Interconnected Thermal Power Plant and its Control with a New BFA Algorithm
    Civelek, Zafer
    Gorel, Goksu
    Luy, Murat
    Barisci, Necaattin
    Cam, Ertugrul
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2018, 24 (06) : 3 - 10
  • [34] Small-signal stability analysis for two-area interconnected power system with load frequency controller in coordination with FACTS and energy storage device
    Shankar, Ravi
    Bhushan, Ravi
    Chatterjee, Kalyan
    AIN SHAMS ENGINEERING JOURNAL, 2016, 7 (02) : 603 - 612
  • [35] A Comparison of PSO, GA and FA-Based PID Controller for Load Frequency Control of Two-Area Hybrid Power System
    Kumar, Ajay
    Gupta, Deepak Kumar
    Ghatak, Sriparna Roy
    Prusty, Soubhagya Ranjan
    SMART TECHNOLOGIES FOR POWER AND GREEN ENERGY, STPGE 2022, 2023, 443 : 281 - 292
  • [36] Novel load frequency control scheme for an interconnected two-area power system including wind turbine generation and redox flow battery
    Oshnoei, Soroush
    Oshnoei, Arman
    Mosallanejad, Ali
    Haghjoo, Farhad
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 130
  • [37] Dynamic Tuning of the Controller Parameters in a Two-Area Multi-Source Power System for Optimal Load Frequency Control Performance
    Gbadega, Peter Anuoluwapo
    Saha, Akshay Kumar
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2020, 51 : 111 - 129
  • [38] The Bees Algorithm Tuned Sliding Mode Control for Load Frequency Control in Two-Area Power System
    Shouran, Mokhtar
    Anayi, Fatih
    Packianather, Michael
    ENERGIES, 2021, 14 (18)
  • [39] An Efficient Solution to Load-Frequency Control Using Fuzzy-Based Predictive Scheme in a Two-Area Interconnected Power System
    Mazinan, A. H.
    Kazemi, M. F.
    2010 2ND INTERNATIONAL CONFERENCE ON COMPUTER AND AUTOMATION ENGINEERING (ICCAE 2010), VOL 1, 2010, : 289 - 293
  • [40] Load Frequency Control Design of Two Area Interconnected Power System Using GWO
    Elkasem, Ahmed. H. A.
    Kamel, Salah
    Korashy, Ahmed
    Nasrat, Loai
    2019 IEEE CONFERENCE ON POWER ELECTRONICS AND RENEWABLE ENERGY (IEEE CPERE), 2019, : 278 - 283