Treatment of chronic obstructive pulmonary disease in patients with different fractional exhaled nitric oxide levels

被引:13
|
作者
Wu, Yao-Kuang [1 ,2 ]
Su, Wen-Lin [1 ,2 ]
Huang, Chun-Yao [1 ]
Yang, Mei-Chen [1 ,2 ]
Chen, Sin-Yi [1 ]
Lan, Chou-Chin [1 ,2 ]
机构
[1] Taipei Tzu Chi Hosp, Div Pulm Med, Dept Internal Med, Buddhist Tzu Chi Med Fdn, 289 Jianguo Rd, New Taipei, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
关键词
chronic obstructive pulmonary disease; fractional exhaled nitric oxide; inhaled corticosteroid; inflammation; inhaled corticosteroids; EOSINOPHILIC AIRWAY INFLAMMATION; INHALED CORTICOSTEROIDS; COPD; EXACERBATIONS;
D O I
10.1097/MD.0000000000011922
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Some patients with chronic obstructive pulmonary disease (COPD) have eosinophilic inflammation which may be evaluated via the measurement of fractional exhaled nitric oxide (FeNO) like asthma. The aim of this prospective study was to assess whether FeNO levels can be used to identify patients with COPD with eosinophilic inflammation who may respond to inhaled corticosteroid (ICS) therapy. This study included patients (N=112) with COPD (age >18 years) who were divided into 4 groups depending upon whether they had high (>= 25 parts per billion [ppb]) or low (<25 ppb) pretreatment (baseline) FeNO and if they were treated with either ICS plus long-acting beta-agonist (ICS+LABA) or a long-acting muscarinic antagonist (LAMA). The 4 groups were: high FeNO/ICS+LABA, high FeNO/LAMA, low FeNO/ICS+LABA, and low FeNO/LAMA. Outcomes assessed included FeNO, COPD assessment test (CAT), and pulmonary function. The high FeNO/ICS+LABA group had the greatest reduction from baseline in FeNO levels (-25.80 ppb +/- 27.14) compared with the high FeNO/LAMA, low FeNO/ICS+LABA, and low FeNO/LAMA groups (range, -4.45 to 1.31 ppb; P<.001). The high FeNO/ICS+LABA group also showed the greatest improvement in CAT (-7.20), which was statistically larger than the low FeNO/ICS+LABA and low FeNO/LAMA groups (-1.72 and -2.03, respectively). No difference in pulmonary function following treatment was observed across the 4 groups. This study found that patients with high FeNO showed the greatest reduction in FeNO and improvement in CAT with ICS+LABA therapy, supporting the use of FeNO to identify patients who would benefit from ICS use.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Exhaled Nitric Oxide and Steroid Responses in Chronic Obstructive Pulmonary Disease
    Kunisaki, Ken M.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181 (05) : 523 - 524
  • [22] Fractional exhaled nitric oxide: a comparative study in patients with acute exacerbation of chronic obstructive pulmonary disease and bronchial asthma
    Zhu, Hui-Yuan
    Wu, Jing-Shuo
    Zhang, Zhong
    Lan, Ya-Hong
    Yang, Qian
    Li, Xiao-Lin
    Zhou, Li-Na
    Zhang, Ai-Xin
    Wu, Pei-Pei
    Zhang, Guo-Jun
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10565 - 10571
  • [23] Alveolar and bronchial exhaled nitric oxide in chronic obstructive pulmonary disease
    Lehouck, An
    Carremans, Claudia
    De Bent, Kristien
    Decramer, Marc
    Janssens, Wim
    [J]. RESPIRATORY MEDICINE, 2010, 104 (07) : 1020 - 1026
  • [24] Measurement of levels of fractional exhaled nitric oxide in patients with pulmonary tuberculosis
    Yhi, J. Y.
    Park, D. W.
    Min, J-H.
    Park, Y. K.
    Kim, S-H.
    Kim, T-H.
    Sohn, J. W.
    Yoon, H. J.
    Shin, D. H.
    Moon, J-Y.
    [J]. INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2016, 20 (09) : 1174 - 1180
  • [25] Fractional Exhaled Nitric Oxide Testing: Diagnostic Utility in Asthma, Chronic Obstructive Pulmonary Disease, or Asthma-chronic Obstructive Pulmonary Disease Overlap Syndrome
    Miskoff, Jeffrey A.
    Dewan, Asa
    Chaudhri, Moiuz
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)
  • [26] Correlation of fractional exhaled nitric oxide (FeNO) and clinical outcomes in patients with chronic obstructive pulmonary disease: A prospective cohort study
    Keeratichananont, Warangkana
    Kaenmuang, Punchalee
    Geater, Sarayut Lucien
    Denyuk, Ratikorn
    Kanchanakanok, Chitsanupong
    [J]. RESPIRATORY MEDICINE, 2024, 229
  • [27] INHALED β2-AGONIST INCREASES EXHALED NITRIC OXIDE LEVELS IN CHRONIC OBSTRUCTIVE PULMONARY DISEASE
    Amer, M.
    Cowan, J.
    Gray, A.
    Brockway, B.
    Dummer, J.
    [J]. RESPIROLOGY, 2016, 21 : 13 - 13
  • [28] Diagnostic value of fractional exhaled nitric oxide for asthma-chronic obstructive pulmonary disease overlap syndrome
    Guo, Yuanyuan
    Hong, Chunlin
    Liu, Yanhong
    Chen, Huinuan
    Huang, Xiaohua
    Hong, Minli
    [J]. MEDICINE, 2018, 97 (23)
  • [29] Exhaled nitric oxide parameters and functional capacity in chronic obstructive pulmonary disease
    McCurdy, Matthew R.
    Sharafkhaneh, Amir
    Abdel-Monem, Hanan
    Rojo, Javier
    Tittel, Frank K.
    [J]. JOURNAL OF BREATH RESEARCH, 2011, 5 (01)
  • [30] Assessment of the role of fractional exhaled nitric oxide in the diagnosis of asthma-chronic obstructive pulmonary disease overlap
    Shebl, Eman
    Moety, Hanaa A.
    [J]. EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2020, 69 (04): : 620 - 626