An efficient coordinated strategy for frequency stability in hybrid power systems with renewables considering interline power flow controller and redox flow battery

被引:16
|
作者
Ahmed, Mohamed [1 ]
Magdy, Gaber [2 ]
Khamies, Mohamed [3 ]
Kamel, Salah [3 ]
机构
[1] Sohag Univ, Fac Engn, Dept Elect Engn, Sohag 82524, Egypt
[2] Aswan Univ, Fac Energy Engn, Dept Elect Engn, Aswan 81528, Egypt
[3] Aswan Univ, Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
关键词
Load frequency control (LFC); Tilted fractional-order integral (TI.); Proportional fractional-order derivative with filter ((PDN)-N-mu); Renewable energy sources (RESs); Artificial gorilla troops optimizer (GTO); DYNAMIC SECURITY; AGC;
D O I
10.1016/j.est.2022.104835
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a new load frequency control (LFC) structure based on a tilt fraction-order integral (TI lambda) controller (i.e., as a feed-forward controller) and a proportional fraction-order derivative controller with a filter ((PDN)-N-mu) (i.e., as a feedback controller), referred to as TI lambda - (PDN)-N-mu controller. This proposed controller is optimally designed using a recent optimization algorithm, artificial gorilla troops optimizer (GTO). Where the proficiency of the new optimization algorithm (GTO) is verified over other optimization algorithms used in the literature (e. g., differential evolution and firefly algorithms) based on statistical tests. Also, the superiority of the proposed TI lambda - (PDN)-N-mu controller's performance is validated by comparing it with another proposed (PDN)-N-mu - TI lambda controller beside other controllers from the literature (e.g., (PID mu)-D-lambda and ITD controllers). The power system under investigation in this work is a two-area hybrid power system in which each area incorporates a thermal power plant with a reheat turbine, a hydropower plant, and a generation unit by gas. Additionally, the considered power system with the proposed controller is also examined under the influence of the high penetration of renewables. Furthermore, this paper proposes new efficient coordination between the proposed TI lambda - (PDN)-N-mu controller based LFC, an interline power flow controller, and a redox flow battery, to ensure robust performance and further frequency stability for the considered hybrid power system against loads/renewables fluctuations, system uncertainties, and communication time delays. The simulation results carried out by MATLAB prove that the proposed coordination scheme based on the proposed GTO algorithm enhances system frequency stability significantly under a variety of load perturbations, renewable power fluctuations, communication time delays, system uncertainties, and physical constraints.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Optimal Placement of Interline Power Flow Controller (IPFC) to enhance Voltage Stability
    Reddy, B. V. Rami
    Reddy, Y. V. Siva
    Sujatha, P.
    2015 CONFERENCE ON POWER, CONTROL, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES FOR SUSTAINABLE GROWTH (PCCCTSG), 2015, : 78 - 84
  • [32] INTERLINE POWER FLOW CONTROLLER AND IMPACT ON ATC IMPROVEMENT
    Hosseini, S. M. H.
    Talebi, N.
    Dehghanpour, A.
    PROCEEDINGS OF THE 2011 3RD INTERNATIONAL CONFERENCE ON SOFTWARE TECHNOLOGY AND ENGINEERING (ICSTE 2011), 2011, : 643 - 651
  • [33] Application of Interline Power Flow Controller (IPFC) to power oscillation damping
    Zhang, Jun
    Yokoyama, Akihiko
    Ide, Toshiro
    IEEJ Transactions on Power and Energy, 2008, 128 (10) : 1252 - 1258
  • [34] Energy function for an interline power-flow controller
    Azbe, V.
    Mihalic, R.
    ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (06) : 945 - 952
  • [35] An optimal power flow control method of power system using Interline Power Flow Controller (IPFC)
    Teerathana, S
    Yokoyama, A
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C343 - C346
  • [36] Optimal output power coordinated control strategy of distributed power flow controller
    Tang, Aihong
    Zhou, Wei
    Song, Jingen
    Qiu, Peng
    Chen, Qian
    Zhai, Xiaohui
    Yang, Huiyuan
    Xiong, Binyu
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 140
  • [37] Optimized utilization of interline power flow controller in an integrated power system
    Mishra, Akanksha
    Kumar, G. V. Nagesh
    Bali, Sravana Kumar
    WORLD JOURNAL OF ENGINEERING, 2020, 17 (02) : 261 - 266
  • [38] The effect of Interline Power Flow Controller (IPFC) on damping interarea oscillations in the interconnected power systems
    Kazemi, A.
    Karimi, E.
    PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 769 - 773
  • [39] An interline DC power flow controller suitable for VSC-MTDC systems
    School of Electrical Engineering, Southeast University, Nanjing
    210096, China
    不详
    210096, China
    不详
    100085, China
    Dianli Xitong Zidonghue, 11 (76-82):
  • [40] Optimal power flow operation of an interline current flow controller in an hybrid AC/DC meshed grid
    Sau-Bassols, Joan
    Zhao, Quanyu
    Garcia-Gonzalez, Javier
    Prieto-Araujo, Eduardo
    Gomis-Bellmunt, Oriol
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 177