Detecting and close-loop control methods for selective-harmonic-compensation active power filter

被引:0
|
作者
Wang, H [1 ]
Zhang, C [1 ]
Yang, G [1 ]
Du, JH [1 ]
机构
[1] Tsing Hua Univ, Dept Automat, Beijing 100084, Peoples R China
关键词
power filter; selective harmonic detection; DC voltage control; close-loop control;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a selective harmonic detecting method and a new close-loop control algorithm for selective-harmonic-compensation active power filters (SHC-APF). The SHC-APF consists of a selective detection unit, DC voltage control and current control loops. Selective harmonic detection unit detects precisely the selected harmonic currents instead of all harmonics produced by distorting loads. At the same time, the unit adds a preceding compensatory angle in order to compensate the infection of delays caused by the digital controller and voltage-source inverter (VSI). The algorithms for the closed-loop control are discussed. Simulations for the harmonic detection and control loop response are implemented and the results confirm the theoretical analysis.
引用
收藏
页码:206 / 209
页数:4
相关论文
共 50 条
  • [11] A Modified Method of Selective Harmonic Compensation or Three-Level Active Power Filter
    Feng, Ling
    Wang, Yong
    [J]. 2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [12] High-Performance Resonant Controller for Active Power Filter with Selective Harmonic Compensation
    Zeng, Zheng
    Zhao, Shan
    Yang, Jiaqiang
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2578 - 2583
  • [13] Active Power Filter Commitment for Harmonic Compensation in Microgrids
    Marini, Abbas
    Piegari, Luigi
    Mortazavi, Seyed Saeedallah
    Ghazizadeh, Mohammad-Sadegh
    [J]. 45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 7038 - 7044
  • [14] An improved harmonic detecting approach for active power filter
    Ma, L
    Zhou, JH
    Lu, ZY
    Qian, ZM
    [J]. IPEMC 2000: THIRD INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, PROCEEDINGS, 2000, : 1420 - 1424
  • [15] Experimental Implementation of Power Packet Density Modulation to Close-loop Control of Manipulator
    Mochiyama, Shiu
    Hikihara, Takashi
    [J]. 2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 762 - 767
  • [16] OTA-based control system of active power filter for harmonic and reactive power compensation
    Vanichprapa, S
    Chipipop, B
    Koompai, C
    Watanabe, T
    [J]. SCS 2003: INTERNATIONAL SYMPOSIUM ON SIGNALS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2003, : 221 - 224
  • [17] Harmonic Elimination and Reactive Power Compensation with a Novel Control Algorithm based Active Power Filter
    Garanayak, Priyabrat
    Panda, Gayadhar
    [J]. JOURNAL OF POWER ELECTRONICS, 2015, 15 (06) : 1619 - 1627
  • [18] OTA-based control system of active power filter for harmonic and reactive power compensation
    Vanichprapa, S
    Chipipop, B
    Koompai, C
    Watanabe, K
    [J]. CCA 2003: PROCEEDINGS OF 2003 IEEE CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 2003, : 301 - 305
  • [19] Repetitive-based control for selective harmonic compensation in active power filters
    Mattavelli, P
    Marafao, FP
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (05) : 1018 - 1024
  • [20] Delay loop current control methods of Shunt Active Power Filter
    Liu, Gui-ying
    Su, Shi-ping