Active control of Nanjing TV transmission tower with lateral-torsional motion

被引:1
|
作者
Wu, JC [1 ]
Yang, JN [1 ]
机构
[1] Tamkang Univ, Dept Civil Engn, Taipei, Taiwan
关键词
active mass driver; Linear Quadratic Gaussian (LQG) control; reduced-order system; dynamic output feedback; lateral-torsional motion;
D O I
10.1117/12.310613
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A 310 m Nanjing TV transmission tower in China will be installed with an active mass driver on the upper observation deck in order to reduce the acceleration responses under strong winds. The wind-induced structural responses considered in this paper include the coupling effect of lateral and torsional motions. The along-wind and across-wind components of the wind velocity are modeled as random processes defined by the Davenport cross-power spectra. The structural responses, in particular the acceleration, increase due to the coupling effect of lateral and torsional motions. This paper presents the Linear Quadratic Gaussian (LQG) control strategy using accelerations as the feedback quantities to reduce the tower response. Emphasis is placed on the practical applications, such as the limitations on actuator peak force and stroke, limited number of sensors, noise pollution, etc. A state reduced-order system has been established to design the dynamic output feedback controllers. The power spectral density and rms of acceleration responses of the TV transmission tower equipped with an active mass driver have been computed. Simulation results demonstrate that the L&G strategy is remarkable in reducing the lateral and torsional motions of the tower and it is suitable for the full-scale implementation of active mass driver on Nanjing Tower.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 48 条
  • [41] Integrated attitude motion and lateral stability control of a vehicle via active suspension and rear-wheel steering control system
    Wu, L.
    Youn, I.
    Tomizuka, M.
    DYNAMICS OF VEHICLES ON ROADS AND TRACKS, 2016, : 365 - 374
  • [42] Semi-active control of wind-induced responses of transmission tower-line system by using magnetorheological dampers
    Chen, B.
    Zheng, J.
    Qu, W. L.
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 1019 - +
  • [43] Semi-active control for wind-induced responses of transmission tower-line system using friction dampers
    Chen, Bo
    Qu, Wei-Lian
    Zheng, Jin
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (01): : 221 - 226
  • [44] Semi-active vibration control of a transmission system using a magneto-rheological variable stiffness and damping torsional vibration absorber
    Li, Wenfeng
    Dong, Xiaomin
    Xi, Jun
    Deng, Xiong
    Shi, Kaiyuan
    Zhou, Yaqin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2021, 235 (10-11) : 2679 - 2698
  • [45] Stabilizing Electric Vehicle Lateral Motion with Considerations of State Delay of Active Front Steering System through Robust Control
    Jin, XianJian
    Yin, Guodong
    Zhang, Ning
    Chen, Jiansong
    2016 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2016, : 616 - 620
  • [46] Semi-active control for wind-induced vibration of a high-rise steel TV tower with MR-MTSD & MR-PTTMD dampers
    Zhengzhou University, Zhengzhou 450001, China
    不详
    不详
    Tumu Gongcheng Xuebao, 2009, 8 (17-25): : 17 - 25
  • [47] Vieta-Lucas polynomials-based collocation simulation to analyze the solvent fraction factor in active and passive control flow induced by torsional motion
    Kumar, Ravikumar Shashikala Varun
    Kumar, Rangaswamy Naveen
    Raghunandan, Mavinakere Eshwaraiah
    Prasannakumara, Ballajja Chandrappa
    PHYSICS OF FLUIDS, 2024, 36 (11)
  • [48] Discussion of "Cross Correlations of Modal Responses of Tall Buildings in Wind-Induced Lateral-Torsional Motion" by M. F. Huang, C. M. Chan, K. C. S. Kwok, and P. A. Hitchcock
    Chen, Xinzhong
    Kareem, Ahsan
    JOURNAL OF ENGINEERING MECHANICS, 2011, 137 (02) : 151 - 154