ANALYSIS OF REGIONAL SUITABILITY OF THE GROUND-COUPLED HEAT PUMP BASED ON THE SHALLOW GROUND THERMAL BALANCE

被引:0
|
作者
Gao, Yuefen [1 ]
Wang, Songling [1 ]
Zhang, Guoqiang
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding 071003, Hebei, Peoples R China
关键词
regional suitability; ground-coupled heat pump system (GHP); ground heat exchanger (GHX); thermal balance; Imbalance Ratio; Extracted Heat to Rejected Heat Ratio;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ground-coupled heat pump systems use the ground as a heat source and sink either with vertical or horizontal ground heat exchangers (GHXs) to supply heating in winter and cooling in summer. The ground heat source and sink has a near constant temperature, which is well suited to ground-coupled heat pumps, giving them consistent performance, regardless of the outdoor temperature. However, when the heat extracted from and rejected to the ground has great imbalance, the ground temperature will deviate from the original temperature with a long term operation. The deviation can reduce GHX performance greatly. As China has vast territory with variety climate, the annual cooling loads and heating loads are different at different places. And the imbalance between the extracted heat and the rejected heat also varies at different places. Therefore, it is necessary to analysis the regional suitability of the ground-coupled heat pump systems. The imbalance between the extracted heat and the rejected heat is analyzed by taking several typical cities in different climates. The new concepts of the Imbalance Ratio and the Extracted Heat to Rejected Heat Ratio are introduced as the weight factors to measure the imbalance in the ground. The values of the Imbalance Ratio and those of the Extracted Heat to the Rejected Heat Ratio are calculated. The optimum range of the Imbalance Ratio is recommended based on the vast investigation of the ground-coupled heat pumps. Some supplemental systems are put forward to supply heat in winter or to reject heat in summer at the places existing serious heat imbalance. The study is very meaningful to the scientific application of the ground-coupled heat pump systems in China.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 50 条
  • [31] Energy-saving Analysis of a Hybrid Ground-coupled Heat Pump Project
    Xue, Qin
    Chen, Jiufa
    Zheng, Hongqi
    Qiao, Weilai
    An, Erming
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 436 - 443
  • [32] Ground-coupled heat pump system with a buried underfloor heat exchanger
    Den Braven, Karen R.
    Drown, David C.
    American Society of Mechanical Engineers, Advanced Energy Systems Division (Publication) AES, 1992, 28 : 97 - 101
  • [33] GROUND-COUPLED HEAT-PUMP SYSTEM EXPERIMENTAL RESULTS
    METZ, P
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59
  • [34] Research and application of ground-coupled heat pump and ice storage
    College of Thermal Energy Engineering, Shandong Jianzhu Univ, Jinan, Shandong 250101, China
    不详
    Hunan Daxue Xuebao, 2009, SUPPL. 2 (40-43): : 40 - 43
  • [35] An in situ thermal response test for borehole heat exchangers of the ground-coupled heat pump system
    Yang, Weibo
    Chen, Zhenqian
    Shi, Mingheng
    Zhang, Chengbin
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 489 - 503
  • [36] Exergy Analysis of a Ground-Coupled Heat Pump Heating System with Different Terminals
    Chen, Xiao
    Hao, Xiaoli
    ENTROPY, 2015, 17 (04): : 2328 - 2340
  • [37] Study on Thermal Resistance of Coaxial Tube Boreholes in Ground-Coupled Heat Pump Systems
    Fang, Liang
    Diao, Nairen
    Shao, Zhukun
    Wang, Zuotao
    Fang, Zhaohong
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3735 - 3742
  • [38] Extended State Observer Based Control for Ground-Coupled Heat Pump System
    Zhang Yu
    Wang Junxiao
    Li Shihua
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 4863 - 4868
  • [39] Evaluation of subsurface thermal environmental change caused by a ground-coupled heat pump system
    Fujimitsu, Yasuhiro
    Fukuoka, Koichiro
    Ehara, Sachio
    Takeshita, Hiroto
    Abe, Fuminori
    CURRENT APPLIED PHYSICS, 2010, 10 : S113 - S116
  • [40] Experimental research on shallow coaxial tube ground-coupled heat exchangers of ground-source heat pump for heating in winter and cooling in summer
    Hu, MM
    Ding, Y
    Wei, TD
    Lui, XY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 284 - 289