ANALYSIS OF REGIONAL SUITABILITY OF THE GROUND-COUPLED HEAT PUMP BASED ON THE SHALLOW GROUND THERMAL BALANCE

被引:0
|
作者
Gao, Yuefen [1 ]
Wang, Songling [1 ]
Zhang, Guoqiang
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding 071003, Hebei, Peoples R China
关键词
regional suitability; ground-coupled heat pump system (GHP); ground heat exchanger (GHX); thermal balance; Imbalance Ratio; Extracted Heat to Rejected Heat Ratio;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ground-coupled heat pump systems use the ground as a heat source and sink either with vertical or horizontal ground heat exchangers (GHXs) to supply heating in winter and cooling in summer. The ground heat source and sink has a near constant temperature, which is well suited to ground-coupled heat pumps, giving them consistent performance, regardless of the outdoor temperature. However, when the heat extracted from and rejected to the ground has great imbalance, the ground temperature will deviate from the original temperature with a long term operation. The deviation can reduce GHX performance greatly. As China has vast territory with variety climate, the annual cooling loads and heating loads are different at different places. And the imbalance between the extracted heat and the rejected heat also varies at different places. Therefore, it is necessary to analysis the regional suitability of the ground-coupled heat pump systems. The imbalance between the extracted heat and the rejected heat is analyzed by taking several typical cities in different climates. The new concepts of the Imbalance Ratio and the Extracted Heat to Rejected Heat Ratio are introduced as the weight factors to measure the imbalance in the ground. The values of the Imbalance Ratio and those of the Extracted Heat to the Rejected Heat Ratio are calculated. The optimum range of the Imbalance Ratio is recommended based on the vast investigation of the ground-coupled heat pumps. Some supplemental systems are put forward to supply heat in winter or to reject heat in summer at the places existing serious heat imbalance. The study is very meaningful to the scientific application of the ground-coupled heat pump systems in China.
引用
收藏
页码:741 / 746
页数:6
相关论文
共 50 条
  • [1] Optimization and Analysis of a Vertical Ground-Coupled Heat Pump
    Kord, Ali Siavoshi
    Jazayeri, Seyed Ali
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (01): : 33 - 37
  • [2] Financial and economic analysis for ground-coupled heat pumps using shallow ground heat exchangers
    Gabrielli, Laura
    Bottarelli, Michele
    SUSTAINABLE CITIES AND SOCIETY, 2016, 20 : 71 - 80
  • [3] GROUND-COUPLED HEAT-PUMP RESEARCH
    BOSE, J
    PARKER, J
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59
  • [5] THE GROUND-COUPLED HEAT PUMP TECHNOLOGY IN CHINA
    Fang, Zhaohong
    Diao, Nairen
    Cui, Ping
    Yu, Mingzhi
    PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 735 - 740
  • [6] Ground-Coupled Heat Pump and Energy Storage
    Lohrenz, Ed
    Almeida, Sergio
    ASHRAE JOURNAL, 2013, 55 (04) : 14 - +
  • [7] The modeling of ground-coupled heat pump systems
    Qu, Yun-Xia
    Li, An-Gui
    Zhang, Lin-Hua
    Fang, Zhao-Hong
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture and Technology, 2007, 39 (02): : 235 - 239
  • [8] GROUND-COUPLED HEAT-PUMP SYSTEM
    DROWN, DC
    DENBRAVEN, KR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (08): : 14 - 14
  • [9] A review on thermal response test of ground-coupled heat pump systems
    Zhang, Changxing
    Guo, Zhanjun
    Liu, Yufeng
    Cong, Xiaochun
    Peng, Donggen
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 40 : 851 - 867
  • [10] A review on thermal response test of ground-coupled heat pump systems
    Zhang, C. (zcx952@163.com), 1600, Elsevier Ltd (40):