High-resolution atheroma mixture modeled MRI

被引:0
|
作者
Pearlman, JD [1 ]
Sukhatme, VV [1 ]
机构
[1] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Boston, MA 02115 USA
来源
关键词
D O I
10.1117/12.309545
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Introduction: In chemically sensitive MRT, similar signals from the atheroma that blocks arteries and from perivascular fat, due to partial volume effects, can result in a mixed signal. Methods: MRI of pure samples and of blood vessels containing 10 different ratios of atheroma and perivascular fat were acquired by inversion recovery MRI. Mixture modeling deduced component signals, and distribution analysis enabled conversion of dynamic range to enhanced resolution. Imaging was repeated at high resolution (long acquisition) for validation of resolution enhancement. Monte Carlo methods were applied to examine error propagation. Quantitation of atheroma content corresponds accurately to measured samples (r=.997). Results: Mixture modeling correctly identified components with rms error <5%. Multiresolution imaging confirmed that redistribution converts dynamic range to enhanced spatial resolution. The resolution enhancement agrees well with direct high-resolution acquisition, achieving 256x improvement in effective in-plane resolution. Conclusion. Mixture modeling correctly identifies atheroma vs. perivascular fat signal components, and resolution-enhancement converts the results to high spatial resolution maps of the components. The resolution-enhanced images agree well with the true high-resolution acquisition. They are faster to acquire, more practical, and provide better tissue characterization, including quantitation of the atheroma lipid burden in the vessel.
引用
收藏
页码:229 / 238
页数:10
相关论文
共 50 条
  • [21] HIGH-RESOLUTION CINE MRI OF VESSEL DISTENSION
    CHIEN, D
    SALONER, D
    LAUB, G
    ANDERSON, CM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) : 576 - 580
  • [22] Hypoplasia or stenosis: Usefulness of high-resolution MRI
    Mariani, L. L.
    Klein, I.
    Pico, Fernando
    REVUE NEUROLOGIQUE, 2011, 167 (8-9) : 619 - 621
  • [23] CRANIOPHARYNGIOMA - CORRELATION OF HIGH-RESOLUTION CT AND MRI
    PRICE, AC
    RUNGE, V
    ALLEN, JH
    KESSLER, RM
    SANDLER, M
    PARTAIN, CL
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (03) : 465 - 465
  • [24] MRI AND HIGH-RESOLUTION CT OF PITUITARY ABSCESS
    DICKOB, M
    SCHARPHUIS, T
    DISTELMAIER, P
    HOFFMANN, G
    NEUROCHIRURGIA, 1989, 32 (06) : 184 - 186
  • [25] High-resolution MRI of the hypothalamus in multiple sclerosis
    Mills, R. J.
    Young, C. A.
    Smith, T.
    MULTIPLE SCLEROSIS, 2006, 12 : S173 - S174
  • [26] MRI Assessment of Sacroiliitis With High-Resolution Protocol
    Berkowitz, Jennifer L.
    Mandl, Lisa A.
    Burge, Alissa J.
    Roberts, John A.
    Lin, Bin
    Schwartzman, Sergio
    Carrino, John A.
    HSS JOURNAL, 2022, 18 (01) : 91 - 97
  • [27] Temporal and Spatial Interpolation Errors of High-Resolution Modeled Atmospheric Fields
    Prive, N. C.
    Errico, R. M.
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2016, 33 (02) : 303 - 311
  • [28] DIRECT MIXTURE ANALYSIS BY HIGH-RESOLUTION MS MS
    GREEN, BN
    BATEMAN, RH
    TUMMERS, MH
    SMITH, DC
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 316 (02): : 217 - 220
  • [29] HIGH-RESOLUTION H-1-NMR SPECTRAL SIGNATURE FROM HUMAN ATHEROMA
    PEARLMAN, JD
    ZAJICEK, J
    MERICKEL, MB
    CARMAN, CS
    AYERS, CR
    BROOKEMAN, JR
    BROWN, MF
    MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) : 262 - 279
  • [30] Finescale Spiral Rainbands Modeled in a High-Resolution Simulation of Typhoon Rananim (2004)
    李青青
    端义宏
    余晖
    傅刚
    AdvancesinAtmosphericSciences, 2010, 27 (03) : 685 - 704