A force-measuring device combined with ultrasound-based elastography for assessment of the uterine cervix

被引:4
|
作者
Thomsen, Christine Rohr [1 ,2 ]
Jensen, Maria Strandbo Schmidt [1 ,3 ]
Leonhard, Anne Katrine [1 ]
Mortensen, Tanja Osterlund [1 ]
Bor, Pinar [2 ]
Sandager, Puk [1 ,3 ]
Hinge, Mogens [4 ]
Uldbjerg, Niels [1 ]
机构
[1] Aarhus Univ Hosp, Dept Obstet & Gynecol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[2] Randers Reg Hosp, Dept Obstet & Gynecol, Randers, Denmark
[3] Aarhus Univ Hosp, Ctr Fetal Diagnost, Dept Clin Med, Aarhus, Denmark
[4] Aarhus Univ, Dept Biol & Chem Engn, Aarhus, Denmark
关键词
cervical dilatation time; cervical elastography index; cervical softening; cervical strength index; elastography; force-measuring device; labor induction; uterine cervix; SONOGRAPHIC MEASUREMENT; WEEKS GESTATION; LENGTH; LABOR; RISK; PREGNANCY; INDUCTION; MODEL;
D O I
10.1111/aogs.14309
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction In this feasibility study, we hypothesize that the evaluation of cervical biomechanical strength can be improved if cervical length measurement is supplemented with quantitative elastography, which is a technique based on conventional ultrasound elastography combined with a force-measuring device. Our aims were to: (a) develop a force-measuring device; (b) introduce a cervical elastography index (CEI) and a cervical strength index (CSI; defined as cervical length x CEI); (c) evaluate how these indexes assess the cervical softening that takes place during normal pregnancy; and (d) how these indexes predict the cervical dilatation time from 4 to 10 cm. Material and methods An electronic force-measuring device was mounted on the handle of the transvaginal probe, allowing for force measurement when conducting elastography. The study group concerned with normal cervical softening included 44 unselected pregnant women. Outcomes were CEI and CSI at different gestational ages. The study group for labor induction included 26 singleton term pregnant women admitted for labor induction. Outcome was defined as cervical dilatation time from 4 to 10 cm. Elastography measured the changes in mean gray value (intensity) during manual compressions. Region of interest was set within the anterior cervical lip. Results We found that the mean of all variables regarding cervical softening decreased from early to late pregnancy: ie cervical length from 34 to 29 mm, CEI from 0.17 to 0.11 N, and CSI from 5.9 to 3.1 N mm. Moreover, the cervical dilatation time during labor induction was associated with CEI, although not statistically significantly (area under the ROC curve of 0.67), but not with the Bishop score, the cervical length, or the CSI. Conclusions We propose that quantitative elastography based on changes in the intensity of the B-mode ultrasound recording, in combination with a force-measuring device on the handle of the vaginal probe, deserves further investigation as an approach for evaluation of cervical biomechanical strength.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
  • [41] Ultrasound-based transient elastography improves the detection of liver disease in common variable immunodeficiency
    Pecoraro, Antonio
    Crescenzi, Ludovica
    Fiorentino, Andrea
    Morisco, Filomena
    Spadaro, Giuseppe
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2019, 7 (07): : 2507 - 2508
  • [42] Comparison of Shear Velocity Dispersion in Viscoelastic Phantoms Measured by Ultrasound-based Shear Wave Elastography and Magnetic Resonance Elastography
    Urban, Matthew W.
    Chen, Jun
    Ehman, Richard L.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [43] DATA-PROCESSING IN ULTRASOUND-BASED LIQUID LEVEL MEASURING INSTRUMENTS
    NOLL, H
    ALIMENTA, 1985, 24 (05): : 115 - &
  • [44] Ultrasound-based elastography combined with Baveno VI criteria: A new era begins in the prediction of high-risk varices in cirrhotic patients
    Fraquelli, Mirella
    Fichera, Anna
    DIGESTIVE AND LIVER DISEASE, 2023, 55 (08) : 1060 - 1061
  • [45] Advancements in Ultrasound and Ultrasound-Based Risk Stratification Systems for the Assessment of Thyroid Nodule
    Trimboli, Pierpaolo
    CANCERS, 2022, 14 (07)
  • [46] ULTRASOUND-BASED CAROTID ELASTOGRAPHY FOR DETECTION OF VULNERABLE ATHEROSCLEROTIC PLAQUES VALIDATED BY MAGNETIC RESONANCE IMAGING
    Huang, Chengwu
    Pan, Xiaochang
    He, Qiong
    Huang, Manwei
    Huang, Lingyun
    Zhao, Xihai
    Yuan, Chun
    Bai, Jing
    Luo, Jianwen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (02): : 365 - 377
  • [47] Methodological Study to Investigate the Potential of Ultrasound-Based Elastography and Texture as Biomarkers to Monitor Liver Tumors
    Moalla, Salma
    Girot, Charly
    Franchi-Abella, Stephanie
    Ammari, Samy
    Balleyguier, Corinne
    Lassau, Nathalie
    Pitre-Champagnat, Stephanie
    DIAGNOSTICS, 2020, 10 (10)
  • [48] Ultrasound-based transient elastography improves the detection of liver disease in common variable immunodeficiency Reply
    Azzu, Vian
    Fonseca, Mariana
    Kennard, Lucinda
    Duckworth, Adam
    Moini, Nasreen
    Qurashi, Maria
    Brais, Rebecca
    Davies, Sue
    Manson, Ania
    Staples, Emily
    Kumararatne, Dinakantha S.
    Griffiths, William J. H.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2019, 7 (07): : 2508 - 2509
  • [49] Ultrasound-based radiomics for the evaluation of fetal rat lung maturity: A noninvasive assessment method (Ultrasound-based radiomics in fetal rat lung)
    Du, Yanran
    Jiao, Jing
    Cao, Aili
    Ji, Chao
    Li, Man
    Ji, Chenli
    Wu, Yang
    Guo, Yi
    Wang, Yuanyuan
    Zhou, Jianqiao
    Ren, Yunyun
    PRENATAL DIAGNOSIS, 2022, 42 (11) : 1429 - 1437
  • [50] DATA-PROCESSING IN ULTRASOUND-BASED LIQUID LEVEL-MEASURING INSTRUMENTS
    NOLL, H
    TECHNISCHES MESSEN, 1984, 51 (09): : 313 - 317