A force-measuring device combined with ultrasound-based elastography for assessment of the uterine cervix

被引:4
|
作者
Thomsen, Christine Rohr [1 ,2 ]
Jensen, Maria Strandbo Schmidt [1 ,3 ]
Leonhard, Anne Katrine [1 ]
Mortensen, Tanja Osterlund [1 ]
Bor, Pinar [2 ]
Sandager, Puk [1 ,3 ]
Hinge, Mogens [4 ]
Uldbjerg, Niels [1 ]
机构
[1] Aarhus Univ Hosp, Dept Obstet & Gynecol, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[2] Randers Reg Hosp, Dept Obstet & Gynecol, Randers, Denmark
[3] Aarhus Univ Hosp, Ctr Fetal Diagnost, Dept Clin Med, Aarhus, Denmark
[4] Aarhus Univ, Dept Biol & Chem Engn, Aarhus, Denmark
关键词
cervical dilatation time; cervical elastography index; cervical softening; cervical strength index; elastography; force-measuring device; labor induction; uterine cervix; SONOGRAPHIC MEASUREMENT; WEEKS GESTATION; LENGTH; LABOR; RISK; PREGNANCY; INDUCTION; MODEL;
D O I
10.1111/aogs.14309
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction In this feasibility study, we hypothesize that the evaluation of cervical biomechanical strength can be improved if cervical length measurement is supplemented with quantitative elastography, which is a technique based on conventional ultrasound elastography combined with a force-measuring device. Our aims were to: (a) develop a force-measuring device; (b) introduce a cervical elastography index (CEI) and a cervical strength index (CSI; defined as cervical length x CEI); (c) evaluate how these indexes assess the cervical softening that takes place during normal pregnancy; and (d) how these indexes predict the cervical dilatation time from 4 to 10 cm. Material and methods An electronic force-measuring device was mounted on the handle of the transvaginal probe, allowing for force measurement when conducting elastography. The study group concerned with normal cervical softening included 44 unselected pregnant women. Outcomes were CEI and CSI at different gestational ages. The study group for labor induction included 26 singleton term pregnant women admitted for labor induction. Outcome was defined as cervical dilatation time from 4 to 10 cm. Elastography measured the changes in mean gray value (intensity) during manual compressions. Region of interest was set within the anterior cervical lip. Results We found that the mean of all variables regarding cervical softening decreased from early to late pregnancy: ie cervical length from 34 to 29 mm, CEI from 0.17 to 0.11 N, and CSI from 5.9 to 3.1 N mm. Moreover, the cervical dilatation time during labor induction was associated with CEI, although not statistically significantly (area under the ROC curve of 0.67), but not with the Bishop score, the cervical length, or the CSI. Conclusions We propose that quantitative elastography based on changes in the intensity of the B-mode ultrasound recording, in combination with a force-measuring device on the handle of the vaginal probe, deserves further investigation as an approach for evaluation of cervical biomechanical strength.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 50 条
  • [1] Quantitative strain elastography of the uterine cervix assessed by the GE Voluson E10 system in combination with a force-measuring device
    Thomsen, Christine Rohr
    Leonhard, Anne Katrine
    Jensen, Maria Strandbo Schmid
    Bor, Pinar
    Hinge, Mogens
    Uldbjerg, Niels
    Sandager, Puk
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2023, 36 (01):
  • [2] Ultrasound-based liver elastography in the assessment of fibrosis
    Fang, C.
    Lim, A.
    Sidhu, P. S.
    CLINICAL RADIOLOGY, 2020, 75 (11) : 822 - 831
  • [3] MECHANICAL FORCE-MEASURING DEVICE HAVING AN UNFIXED POINT OF APPLICATION OF MONITORED FORCE
    KOSOLAPO.AV
    INDUSTRIAL LABORATORY, 1969, 35 (05): : 755 - &
  • [4] VISCOELASTICITY MEASUREMENT- A NEW ULTRASOUND-BASED ELASTOGRAPHY METHOD IN THE ASSESSMENT OF THE KIDNEY
    Felix-Mihai, Maralescu
    Bob, Flaviu
    Grosu, Iulia Dana
    Schiller, Adalberi
    Petricia, Ligia
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I421 - I421
  • [5] Performance Assessment of Motion Tracking Methods in Ultrasound-based Shear Wave Elastography
    He, Tingting
    Peng, Bo
    Chen, Pengcheng
    Jiang, Jingfeng
    2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2020, : 3643 - 3648
  • [6] ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY IN THE ASSESSMENT OF PATIENTS WITH DIABETIC KIDNEY DISEASE
    Bob, Flaviu
    Grosu, Iulia
    Sporea, Ioan
    Bota, Simona
    Popescu, Alina
    Sima, Alexandra
    Sirli, Roxana
    Petrica, Ligia
    Timar, Romulus
    Schiller, Adalbert
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10): : 2159 - 2166
  • [7] The Concept of a Force-Measuring Device for Ground Testing of Propulsion System Demonstrators
    Vorob’ev A.R.
    Mikhailov E.A.
    Fedorov V.B.
    Russian Aeronautics, 2023, 66 (02): : 409 - 414
  • [8] Ultrasound-based elastography for the diagnosis of portal hypertension in cirrhotics
    Sirli, Roxana
    Sporea, Ioan
    Popescu, Alina
    Danila, Mirela
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (41) : 11542 - 11551
  • [9] Ultrasound-based Hepatic Elastography Origins, Limitations, and Applications
    Cohen, Eric B.
    Afdhal, Nezam H.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2010, 44 (09) : 637 - 645
  • [10] Ultrasound-based transient elastography using a magnetic excitation
    Pavan, Theo Z.
    Sampaio, Diego R. T.
    Carneiro, Antonio A. O.
    Covas, Dimas T.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1846 - 1849