Image Reconstruction in Magnetic Resonance Conductivity Tensor Imaging (MRCTI)

被引:8
|
作者
Degirmenci, Evren [1 ]
Eyuboglu, B. Murat [1 ]
机构
[1] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
关键词
Anisotropic conductivity; electrical impedance; imaging; magnetic resonance; reconstruction; tensor; tomography; ELECTRICAL-IMPEDANCE TOMOGRAPHY; CURRENT-DENSITY; MR-EIT; MREIT; ALGORITHM; SIMULATION;
D O I
10.1109/TMI.2011.2171192
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Almost all magnetic resonance electrical impedance tomography (MREIT) reconstruction algorithms proposed to date assume isotropic conductivity in order to simplify the image reconstruction. However, it is well known that most of biological tissues have anisotropic conductivity values. In this study, four novel anisotropic conductivity reconstruction algorithms are proposed to reconstruct high resolution conductivity tensor images. Performances of these four algorithms and a previously proposed algorithm are evaluated in several aspects and compared.
引用
收藏
页码:525 / 532
页数:8
相关论文
共 50 条
  • [41] Diffusion tensor magnetic resonance imaging of prostate cancer
    Manenti, Guglielmo
    Carlani, Marco
    Mancino, Stefano
    Colangelo, Vittorio
    Di Roma, Mauro
    Squillaci, Ettore
    Simonetti, Giovanni
    INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 412 - 419
  • [42] On image registration in magnetic resonance imaging
    Qiu, Peihua
    Nguyen, Tram
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 753 - +
  • [43] Diffusion tensor magnetic resonance imaging in multiple sclerosis
    Filippi, M
    Cercignani, M
    Inglese, M
    Horsfield, MA
    Comi, G
    NEUROLOGY, 2001, 56 (03) : 304 - 311
  • [44] Diffusion tensor magnetic resonance imaging of brain tumors
    Cruz, LCH
    Sorensen, AG
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2005, 16 (01) : 115 - +
  • [45] Noise removal in magnetic resonance diffusion tensor imaging
    Chen, B
    Hsu, EW
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 393 - 401
  • [46] Image reconstruction using shift-variant resampling kernel for magnetic resonance imaging
    Fahmy, AS
    Tawfik, BS
    Kadah, YM
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 825 - 833
  • [47] Deep learning in magnetic resonance image reconstruction
    Chandra, Shekhar S.
    Bran Lorenzana, Marlon
    Liu, Xinwen
    Liu, Siyu
    Bollmann, Steffen
    Crozier, Stuart
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2021, 65 (05) : 564 - 577
  • [48] Anisotropic conductivity tensor imaging using magnetic induction tomography
    Guersoy, D.
    Scharfetter, H.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S135 - S145
  • [49] Conductivity tensor imaging of the brain using diffusion-weighted magnetic resonance imaging (vol 93, pg 6730, 2003)
    Sekino, Masaki
    Yamaguchi, Kikuo
    Iriguchi, Norio
    Ueno, Shoogo
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (05)
  • [50] Imaging of Brain Tumors: Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging
    Gupta, Ajay
    Shah, Akash
    Young, Robert J.
    Holodny, Andrei I.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2010, 20 (03) : 379 - +