A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring

被引:1
|
作者
Signorini, DF [1 ]
Shad, A [1 ]
Piper, IR [1 ]
Statham, PFX [1 ]
机构
[1] Univ Edinburgh, Dept Clin Neurosci, Edinburgh, Midlothian, Scotland
关键词
intracranial pressure; monitoring; traumatic brain injury;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The strain-gauge Codman MicroSensor intracranial pressure (ICP) transducer has shown consistently good laboratory performance. To assess the practical performance of the system in patients following acute brain injury, 10 patients were fitted with a MicroSensor and a second ICP monitor. In five cases this was a fibre-optic transducer and in five cases an intraventricular fluid-filled device. Paired ICP values were recorded every 5 min. ICP values ranged from 0 to 31 mmHg. Altman-Bland plots showed that individual readings could differ by as much as 9 mmHg. Further analysis showed that much of this disagreement could be explained try a constant offset on each occasion. Comparison traces of ICP in individual patients show high agreement in timing and size of changes. The unexplained constant offset leads to uncertainty about the true ICP. Treatment decisions are often based upon absolute levels of ICP and patient care may therefore differ depending upon the monitor used.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [21] PRELIMINARY REPORT ON CLINICAL MONITORING OF INTRACRANIAL PRESSURE
    史玉泉
    蒋大介
    周范民
    袁士毅
    [J]. 中华医学杂志(英文版), 1980, (12) : 809 - 814
  • [22] Intracranial pressure monitoring: Concepts in evaluation and measurement
    Baral, Bidur
    Agrawal, Amit
    Cincu, Rafael
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2007, 23 (05) : 798 - 804
  • [23] A Near-Infrared Optomechanical Intracranial Pressure Microsensor
    Ghannad-Rezaie, Mostafa
    Yang, Lynda J. -S.
    Garton, Hugh J. L.
    Chronis, Nikos
    [J]. JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (01) : 23 - 33
  • [24] Extreme heating may occur when using intraparenchymal intracranial pressure transducers during mr studies: The Codman microsensor is mr conditional at 3T
    Newcombe, Virginia
    Hawkes, Robert
    Harding, Sally
    Willcox, Roslyn
    Brock, Sarah
    Hutchinson, Peter
    Menon, David
    Carpenter, T. Adrian
    Coles, Jonathan
    [J]. JOURNAL OF NEUROTRAUMA, 2007, 24 (07) : 1234 - 1234
  • [25] MICROCOMPUTER APPLICATION IN CLINICAL INTRACRANIAL-PRESSURE MONITORING
    ALLEN, R
    [J]. INTENSIVE CARE MEDICINE, 1979, 5 (03) : 159 - 159
  • [26] CLINICAL-EVALUATION OF A MINIATURE STRAIN-GAUGE TRANSDUCER FOR MONITORING INTRACRANIAL-PRESSURE
    GOPINATH, SP
    ROBERTSON, CS
    CONTANT, CF
    NARAYAN, RK
    GROSSMAN, RG
    [J]. NEUROSURGERY, 1995, 36 (06) : 1137 - 1140
  • [27] Intracranial pressure monitoring
    Stefini, R.
    Rasulo, F. A.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 : 192 - 195
  • [28] Intracranial pressure monitoring
    Munari, M
    Volpin, SM
    Facco, E
    [J]. ANAESTHESIA, PAIN, INTENSIVE CARE AND EMERGENCY MEDICINE - APICE 19, 2005, : 227 - 235
  • [29] MONITORING OF INTRACRANIAL PRESSURE
    LUNDBERG, N
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1972, 65 (01): : 19 - &
  • [30] Techniques of intracranial monitoring: Intracranial pressure
    Previgliano, IJ
    [J]. Proceedings of the 13th World Congress of Neurological Surgery, Vols 1 and 2, 2005, : 863 - 869