A clinical evaluation of the Codman MicroSensor for intracranial pressure monitoring

被引:1
|
作者
Signorini, DF [1 ]
Shad, A [1 ]
Piper, IR [1 ]
Statham, PFX [1 ]
机构
[1] Univ Edinburgh, Dept Clin Neurosci, Edinburgh, Midlothian, Scotland
关键词
intracranial pressure; monitoring; traumatic brain injury;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The strain-gauge Codman MicroSensor intracranial pressure (ICP) transducer has shown consistently good laboratory performance. To assess the practical performance of the system in patients following acute brain injury, 10 patients were fitted with a MicroSensor and a second ICP monitor. In five cases this was a fibre-optic transducer and in five cases an intraventricular fluid-filled device. Paired ICP values were recorded every 5 min. ICP values ranged from 0 to 31 mmHg. Altman-Bland plots showed that individual readings could differ by as much as 9 mmHg. Further analysis showed that much of this disagreement could be explained try a constant offset on each occasion. Comparison traces of ICP in individual patients show high agreement in timing and size of changes. The unexplained constant offset leads to uncertainty about the true ICP. Treatment decisions are often based upon absolute levels of ICP and patient care may therefore differ depending upon the monitor used.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [1] Clinical evaluation of the Codman microsensor intracranial pressure monitoring system
    Fernandes, HM
    Bingham, K
    Chambers, IR
    Mendelow, AD
    [J]. INTRACRANIAL PRESSURE AND NEUROMONITORING IN BRAIN INJURY, 1998, 71 : 44 - 46
  • [2] Intracranial Pressure Monitoring Using the Codman MicroSensor
    Koskinen, Lars-Owe D.
    Olivecrona, Magnus
    [J]. NEUROSURGERY, 2010, 67 (01) : E221 - E221
  • [3] Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system
    Koskinen, LOD
    Olivecrona, M
    [J]. NEUROSURGERY, 2005, 56 (04) : 693 - 697
  • [4] Clinical experience with the intraparenchymal intracranial pressure monitoring Codman MicroSensor system - Comments
    Liu, CY
    Grossman, RG
    Bullock, MR
    [J]. NEUROSURGERY, 2005, 56 (04) : 697 - 698
  • [5] Subdural intracranial pressure monitoring in severe head injury: clinical experience with the Codman MicroSensor
    Hong, Wei-Chen
    Tu, Yong-Kwang
    Chen, Yuan-Shen
    Lien, Li-Ming
    Huang, Sheng-Jean
    [J]. SURGICAL NEUROLOGY, 2006, 66 : S8 - S13
  • [6] Magnetic Resonance Imaging of the Codman Microsensor Transducer Used for Intraspinal Pressure Monitoring
    Phang, Isaac
    Mada, Marius
    Kolias, Angelos G.
    Newcombe, Virginia F. J.
    Trivedi, Rikin A.
    Carpenter, Adrian
    Hawkes, Rob C.
    Papadopoulos, Marios C.
    [J]. SPINE, 2016, 41 (10) : E605 - E610
  • [7] Left atrial pressure monitoring in patients with a HeartMate II device using a Codman Microsensor
    Gosev, Igor
    Marzia, Leacche
    Neely, Robert C.
    Couper, Gregory S.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04): : 1425 - 1427
  • [8] EVALUATION OF A MICROSENSOR INTRACRANIAL-PRESSURE TRANSDUCER
    GOPINATH, SP
    CHERIAN, L
    ROBERTSON, CS
    NARAYAN, RK
    GROSSMAN, RG
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1993, 49 (1-2) : 11 - 15
  • [9] USE OF A CODMAN® MICROSENSOR INTRACRANIAL PRESSURE PROBE: EFFECTS ON NEAR INFRARED SPECTROSCOPY MEASUREMENTS AND CEREBRAL HEMODYNAMICS IN RATS
    Blockx, Helga
    Flameng, Willem
    De Visscher, Geofrey
    [J]. OXYGEN TRANSPORT TO TISSUE XXX, 2009, 645 : 321 - 327
  • [10] Clinical evaluation of a new intracranial pressure monitoring device
    R. Stendel
    J. Heidenreich
    A. Schilling
    R. Akhavan-Sigari
    R. Kurth
    T. Picht
    T. Pietilä
    O. Suess
    C. Kern
    J. Meisel
    M. Brock
    [J]. Acta Neurochirurgica, 2003, 145 : 185 - 193