Bilateral femoral component breakage in total hip replacement: A case report

被引:0
|
作者
Murray, P [1 ]
Rorabeck, CH [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Breakage of the femoral component of a total hip replacement prosthesis is an uncommon occurrence with modern prostheses. The authors report what appears to be the only case of bilateral prosthetic fracture. A 65-year-old man, who was physically active, suffered bilateral femoral stem fractures 3 and 5 years after to tal hip replacement. The bilateral cemented hip replacements remained asymptomatic until catastrophic failure of the femoral component occurred. Both the prostheses were titanium (Biomet; Warsaw, Ind.) with chrome cobalt modular femoral heads. The authors stress the importance of maintaining an adequate cement mantle in Gruen zones 1 and 7 because failure to do so may result in micromotion and subsequent stem fracture.
引用
收藏
页码:236 / 238
页数:3
相关论文
共 50 条
  • [21] Early Failure of a Modular Femoral Neck Total Hip Arthroplasty Component A Case Report
    Wilson, David A. J.
    Dunbar, Michael J.
    Amirault, John D.
    Farhat, Zoheir
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (06): : 1514 - 1517
  • [22] SUCCESSFUL PREGNANCY AND DELIVERY FOLLOWING BILATERAL TOTAL HIP-REPLACEMENT - REPORT OF CASE
    WITTICH, AC
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1982, 81 (11): : 773 - 775
  • [23] Femoral neck fracture to total femoral replacement: a case report
    Kumar, Gunasekaran
    Dunlop, Colin
    CURRENT ORTHOPAEDIC PRACTICE, 2021, 32 (05): : 535 - 540
  • [24] Total Hip Replacement Interrupted by Intraoperative Arrest with a Final Component in Place: A Case Report
    Fourman, Mitchell Stephen
    Singh, Nina
    McMahon, Patrick J.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (08): : 729 - 732
  • [25] Total Hip Arthroplasty for Bilateral Femoral Neck Stress Fracture: A Case Report and Review of the Literature
    Moerenhout, Kevin
    Gkagkalis, Georgios
    Laflamme, G. -Yves
    Rouleau, Dominique M.
    Leduc, Stephane
    Benoit, Benoit
    ADVANCES IN ORTHOPEDICS, 2019, 2019
  • [26] BENT AND BROKEN FEMORAL PROSTHESES FOLLOWING TOTAL HIP-REPLACEMENT - A CASE-REPORT
    MACFARLANE, I
    DARBY, G
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1978, 48 (03): : 304 - 306
  • [27] Intrapelvic Protrusion of a Femoral Head in A Ceramic-on-Ceramic Total Hip Replacement, A Case Report
    Altell, T.
    Massa, E.
    Edwards, M.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [28] Femoral nerve palsy caused by ileopectineal bursitis after total hip replacement: A case report
    Liman J.
    Von Gottberg P.
    Bähr M.
    Kermer P.
    Journal of Medical Case Reports, 5 (1)
  • [29] Notching of the femoral stem neck in metal-on-metal total hip replacement: a case report
    Leung, Ka-Hei
    Chiu, Kwong-Yuen
    Ng, Fu-Yuen
    Yin, Li
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 113 - 116
  • [30] THE RELATIONSHIP OF BONE MASS AND LOOSENING OF THE FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT
    CARLSSON, AS
    NILSSON, BE
    ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (02): : 285 - 288