Standardisation and half-life measurements of 111In

被引:4
|
作者
Dziel, Tomasz [1 ]
Listkowska, Anna [1 ]
Tyminski, Zbigniew [1 ]
机构
[1] Natl Ctr Nucl Res Radioisotope Ctr POLATOM, Andrzeja Soltana 7, PL-05400 Otwock, Poland
关键词
In-111; Standardisation; 4 pi(LS)-gamma coincidence and anticoincidence; Half-life measurements;
D O I
10.1016/j.apradiso.2015.11.105
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The standardisation of In-111 by 4 pi(LS)-gamma coincidence and anticoincidence counting is presented. Absolute measurements were performed for samples with different concentrations of carrier solution and for different Window settings in the gamma channel. The radioactive concentration of the master solution determined on the same reference date was consistent for all measurements performed. The evaluated typical uncertainty was 0.43%. The half-life of In-111 was determined using a time series of measurements performed with an ionisation chamber. A least squares fit of the measured data resulted in a half-life of 2.8067 (34) days consistent with Decay Data Evaluation Project recommended value (0.064% higher than the DDEP value). (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:345 / 348
页数:4
相关论文
共 50 条
  • [1] Standardisation and half-life of 89Zr
    Garcia-Torano, E.
    Peyres, V.
    Roteta, M.
    Mejuto, M.
    Sanchez-Cabezudo, A.
    Romero, E.
    APPLIED RADIATION AND ISOTOPES, 2018, 134 : 421 - 425
  • [2] The half-life of 111mPd
    Richard M. Lindstrom
    Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 605 - 607
  • [3] The half-life of 111mPd
    Lindstrom, Richard M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 605 - 607
  • [4] HALF-LIFE MEASUREMENTS AT THE PTB
    WALZ, KF
    DEBERTIN, K
    SCHRADER, H
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08): : 1191 - 1199
  • [5] Standardisation and precise determination of the half-life of 44Sc
    Garcia-Torano, E.
    Peyres, V.
    Roteta, M.
    Sanchez-Cabezudo, A. I.
    Romero, E.
    Martinez Ortega, A.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 314 - 318
  • [6] Half-life determination of 111Ag
    Dong, Jiangpeng
    Bai, Tao
    Dai, Yihua
    Zhang, Xiangbo
    Fan, Jinlong
    Hu, Yaowen
    Song, Xiaojing
    Ma, Yan
    Miao, Liangliang
    Shi, Quanlin
    Li, Zhiming
    APPLIED RADIATION AND ISOTOPES, 2023, 194
  • [7] HALF-LIFE MEASUREMENTS IN EMULSION POLYMERIZATION
    LEY, GJM
    SCHNEIDE.C
    HUMMEL, DO
    JOURNAL OF POLYMER SCIENCE PART C-POLYMER SYMPOSIUM, 1969, (27PC): : 119 - &
  • [8] Half-life ... What half-life?
    Lewis, BJ
    JOURNAL OF MANAGEMENT IN ENGINEERING, 1998, 14 (01) : 4 - 4
  • [9] A case of understated uncertainties in half-life measurements
    Pomm, S.
    Pelczar, K.
    NUCLEAR DATA SHEETS, 2024, 196 : 12 - 16
  • [10] HALF-LIFE MEASUREMENTS OF LEVELS IN 75AS
    HOJEBERG, M
    MALMSKOG, SG
    NUCLEAR PHYSICS A, 1969, A133 (03) : 691 - &