Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: A study in 10 cadaver femora

被引:17
|
作者
Kort, N. P.
van Raay, J. J. A. M.
Thomassen, B. J. W.
机构
[1] Martini Hosp, Dept Orthoped, NL-9700 RM Groningen, Netherlands
[2] Maasland Hosp, Dept Orthoped, NL-6130 MB Sittard, Netherlands
来源
KNEE | 2007年 / 14卷 / 04期
关键词
unicompartmental knee; alignment; femoral component; intramedullary rod; extramedullary rod;
D O I
10.1016/j.knee.2007.04.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Use of an intramedullary rod is advised for the alignment of the femoral component of an Oxford phase-III prosthesis. There are users moving toward extramedullary alignment, which is merely an indicator of frustration with accuracy of intramedullary alignment. The results of our study with 10 cadaver femora demonstrate that use of a short and long intramedullary femoral rod may result in excessive flexion alignment error of the femoral component. Understanding of the extramedullary alignment possibility and experience with the visual alignment of the femoral drill guide is essential toward minimizing potential errors in the alignment of the femoral component. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:280 / 283
页数:4
相关论文
共 50 条
  • [21] Trajectory of bearing movement during Oxford mobile-bearing unicompartmental knee arthroplasty using a kinematic alignment technique
    Sun Xiaowei
    Lu Feifan
    Guo Wanshou
    Cheng Liming
    Wang Weiguo
    Zhang Qidong
    中华医学杂志英文版, 2023, 136 (05)
  • [22] Advantages and limitations of mobile-bearing unicompartmental knee arthroplasty: an overview of the literature
    Hiranaka, Takafumi
    EXPERT REVIEW OF MEDICAL DEVICES, 2024, 21 (07) : 587 - 600
  • [23] Management of aseptic failure of the mobile-bearing Oxford unicompartmental knee arthroplasty
    Sabah, Shiraz A.
    Lim, Chin Tat
    Middleton, Robert
    von Fritsch, Lennart
    Bottomley, Nicholas
    Jackson, William F. M.
    Price, Andrew J.
    Alvand, Abtin
    KNEE, 2020, 27 (06): : 1721 - 1728
  • [24] Overstuffed medial compartment after mobile-bearing unicompartmental knee arthroplasty
    B. Kerens
    N. P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 952 - 954
  • [25] Mobile-bearing medial unicompartmental knee arthroplasty restores limb alignment comparable to that of the unaffected contralateral limb
    Mullaji, Arun B.
    Shah, Siddharth
    Shetty, Gautam M.
    ACTA ORTHOPAEDICA, 2017, 88 (01) : 70 - 74
  • [26] Is Recovery Faster for Mobile-bearing Unicompartmental than Total Knee Arthroplasty?
    Lombardi, Adolph V., Jr.
    Berend, Keith R.
    Walter, Christopher A.
    Aziz-Jacobo, Jorge
    Cheney, Nicholas A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (06) : 1450 - 1457
  • [27] Sensor Assessment of Gap Balance in Mobile-Bearing Unicompartmental Knee Arthroplasty
    Sun, Xiaowei
    Wang, Qiuyuan
    Ge, Juncheng
    Wang, Weiguo
    Guo, Wanshou
    Zhang, Qidong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (185):
  • [28] Valgus Stress Radiograph Can Predict Alignment Change of Medial Mobile-Bearing Unicompartmental Knee Arthroplasty
    Jiao, Xufeng
    Li, Zheng
    Du, Mincong
    An, Shuai
    Huang, Jiang
    Cao, Guanglei
    ORTHOPAEDIC SURGERY, 2023, 15 (07) : 1847 - 1853
  • [29] Overstuffed medial compartment after mobile-bearing unicompartmental knee arthroplasty
    Kerens, B.
    Kort, N. P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 952 - 954
  • [30] RETRACTED: Effect of sagittal femoral component alignment on biomechanics after mobile-bearing total knee arthroplasty (Retracted Article)
    Koh, Yong-Gon
    Lee, Jin-Ah
    Lee, Hwa-Yong
    Suh, Dong-Suk
    Kim, Hyo-Jeong
    Kang, Kyoung-Tak
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)