Nacre-like Co-Cr-Mo/Ti2O3 coating on the Co-Cr-Mo substrate prepared using spark plasma sintering

被引:2
|
作者
Li, R. T. [1 ,2 ]
Li, Z. [2 ]
Hu, H. L. [2 ]
Liu, Z. Q. [1 ]
Wang, Y. [1 ]
Khor, K. A. [2 ]
机构
[1] Jiangsu Univ, Sch Mech Engn, 301 Xuefu Rd, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
基金
中国国家自然科学基金;
关键词
Composite coating; Sintering; Nacre-like structure; TiO2; Biomedical applications; MECHANICAL-PROPERTIES; CORROSION BEHAVIOR; IN-VITRO; COMPOSITE; DESIGN; CARBIDE; MICROSTRUCTURE; DENSIFICATION; DEFORMATION; BIOACTIVITY;
D O I
10.1016/j.ceramint.2020.01.054
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Despite the common use of Co-Cr-Mo based prostheses in orthopedics, wider medical applications of such implants are often limited by their inherent bioinertness and inadequate adhesion to bone. A bioactive ceramic coating can improve their bonding to bone. In this study, a nacre-like Co-Cr-Mo/Ti2O3 coating on the Co-Cr-Mo substrate was prepared in one single step using spark plasma sintering (SPS). The microstructure, mechanical properties, and biocompatibility of the pellet were extensively studied. The lamellar Co-Cr-Mo and Ti2O3 layers with a thickness of several microns were alternated, resembling the "bricks-and-mortar" microstructure of nacre. Co-Cr-Mo consisted of y phase, e phase and carbide. The interfacial bonding between Co-Cr-Mo and Ti2O3 was strong, which is essential to achieving high ductility. The incorporation of Ti2O3 to form a composite coating led to improved biocompatibility, with MG63 human osteosarcoma cells cultured on the surface exhibiting faster proliferation and higher viability.
引用
收藏
页码:10530 / 10535
页数:6
相关论文
共 50 条
  • [31] Diffusion bonding of Ti-2.5Al-2.5Mo-2.5Zr and Co-Cr-Mo alloys
    He, Guo
    Liu, Honghua
    Tan, Qingbiao
    Ni, Jiahua
    JOURNAL OF ALLOYS AND COMPOUNDS, 2011, 509 (27) : 7324 - 7329
  • [32] Characterization of electrolytic ZrO2 coating on Co-Cr-Mo implant alloys of hip prosthesis
    Yen, SK
    Guo, MJ
    Zan, HZ
    BIOMATERIALS, 2001, 22 (02) : 125 - 133
  • [33] Electrochemical corrosion and metal ion release from Co-Cr-Mo prosthesis with titanium plasma spray coating
    Reclaru, L
    Eschler, PY
    Lerf, R
    Blatter, A
    BIOMATERIALS, 2005, 26 (23) : 4747 - 4756
  • [34] Characterization of Co-Cr-Mo (F-75) Alloy Produced by Solid State Sintering
    Zuraidawani, Che Daud
    Jamaludin, Shamsul Baharin
    Bari, Fazlul
    X-RAY AND RELATED TECHNIQUES, 2011, 173 : 106 - 110
  • [35] Growth and biological tribological property of C/C multilayers on Co-Cr-Mo alloy substrate
    Gou Y.
    Huang N.
    Sun H.
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2011, 31 (05): : 540 - 544
  • [36] Surface analysis of Co-Cr-Mo alloy and Ti substrates silanized with trialkoxysilanes and silane mixtures
    Matinlinna, JP
    Laajalehto, K
    Laiho, T
    Kangasniemi, I
    Lassila, LVJ
    Vallittu, PK
    SURFACE AND INTERFACE ANALYSIS, 2004, 36 (03) : 246 - 253
  • [37] Prediction of influence of Co-Cr-Mo alloy coating on the wear rate of aluminium with HCl solution
    Reddy, Pratapa Y.
    Narayana, Lakshmi K.
    Mallik, M. Kedar
    MATERIALS TODAY-PROCEEDINGS, 2021, 42 : 1287 - 1296
  • [38] Microstructural Characteristic of Co-Cr-Mo Powder Alloy Coating on Stainless Steel by Plasma Transferred Arc Weld Surfacing
    Somunkiran, Ilyas
    Kurt, Bulent
    Buytoz, Soner
    Orhan, Nuri
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2010, 47 (10): : 546 - 559
  • [39] Effect of Sintering on the Physical and Mechanical Properties of Co-Cr-Mo (F-75)/HAP Composites
    Adzali, Nur Maizatul Shima
    Jamaludin, Shamsul Baharin
    Derman, Mohd Nazree
    SAINS MALAYSIANA, 2013, 42 (12): : 1763 - 1768
  • [40] Electrolytic HA/ZrO2 double layers coating on Co-Cr-Mo alloy for orthopaedic applications
    Yen, S. K.
    Lin, C. M.
    Lin, G. S.
    Chen, S. H.
    Medical Device Materials II: Proceedings from the Materials & Processes for Medical Devices Conference 2004, 2005, : 409 - 414