Design, worst case study, and sensitivity analysis of a net -zero energy building for sustainable urban development

被引:10
|
作者
Jabari, Farkhondeh [1 ]
Ghaebi, Hadi [2 ]
Mohammadi-Ivatloo, Behnam [1 ]
Mohammadpourfard, Mousa [3 ,4 ]
Bannae-Sharifian, Mohammad-Bagher [1 ]
机构
[1] Univ Tabriz, Fac Elect & Comp Engn, Tabriz, Iran
[2] Univ Mohaghegh Ardabili, Dept Mech Engn, Ardebil, Iran
[3] Univ Tabriz, Fac Chem & Petr Engn, Tabriz, Iran
[4] Duy Tan Univ, Inst Res & Dev, Da Nang 550000, Vietnam
关键词
Air to water heat pump (AWHP); Gained output ratio (GOR); Sensitivity analysis; POWER-SYSTEM; PREDICTIVE CONTROL; MANAGEMENT-SYSTEM; HEAT-TRANSFER; GAS-TURBINE; FUEL-CELL; SOLAR; STORAGE; OPTIMIZATION; WATER;
D O I
10.1016/j.scs.2019.101991
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a trigeneration facility based on a biogas driven gas turbine cycle for electricity production and an air to water heat pump for simultaneous extraction of cooling and potable water, and evaluates its robustness and effectiveness under different climatic conditions and variable demands. The air to water heat pump, which consists of an inside evaporator fan, expansion device, condenser, evaporator, and a compressor, is installed for supplying the cooling load of a hospital building in summer. In the refrigeration cycle, R134a absorbs heat from the inside warm air for space cooling and releases it to the saline water for driving a desalination process. Maximum values of cooling and electrical demands of a standard hospital building, where is located in south of Iran, over the hottest day of 2018 are considered for the worst case implementation. Engineering equation solver and general algebraic mathematical modeling system are employed to develop the non-linear optimization strategy, find the best operating point of the air to water heat pump based trigeneration plant, and minimize its energy cost under the greatest load level. Moreover, the sensitivity of the gained output ratio of desalination cycle to the relative humidity of the air entering and leaving the humidifier, the dehumidifier and humidifier effectiveness, and the top and bottom temperatures are comprehensively analyzed. The relative humidity of air entering the humidifier and the larger dehumidifier effectiveness have the significant effects on increasing the gained output ratio of the desalination cycle. Due to intense solar irradiation in summer, the seawater temperature naturally increases, which results in larger gained output ratio and higher mass flow rate of pure water.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Design and Automation of Passive and Active Systems for a School Net Zero Energy Building
    Ribeiro, Artur
    Ramos, Joao
    Baptista, Jose
    [J]. PORTUGAL SB10: SUSTAINABLE BUILDING AFFORDABLE TO ALL - LOW COST SUSTAINABLE SOLUTION, 2010, : 415 - 421
  • [42] The potential of net zero energy buildings (NZEBs) concept at design stage for healthcare buildings towards sustainable development
    Abdellah, Roy Hazli
    Masrom, Md Asrul Nasid
    Chen, Goh Kai
    Mohamed, Sulzakimin
    Omar, Roshartini
    [J]. GLOBAL CONGRESS ON CONSTRUCTION, MATERIAL AND STRUCTURAL ENGINEERING 2017 (GCOMSE2017), 2017, 271
  • [43] Using Urban Building Energy Models for the Development of Sustainable Island Energy Systems
    Cevallos-Sierra, Jaime
    Goncalves, Afonso Pinto
    Silva, Carlos Santos
    [J]. ENERGIES, 2024, 17 (13)
  • [44] Research on Collaborative Design of Performance-Refined Zero Energy Building: A Case Study
    Yao, Gang
    Chen, Yuan
    Xie, Wenchi
    Chen, Nan
    Rui, Yue
    Luo, Pingjia
    [J]. ENERGIES, 2022, 15 (19)
  • [45] Energy and economic analysis of building retrofit and energy offset scenarios for Net Zero Energy Buildings
    Leal, Vitor M. S.
    Granadeiro, Vasco
    Azevedo, Isabel
    Boemi, Sofia-Natalia
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2015, 9 (01) : 120 - 139
  • [46] Towards a Net Zero Building Using Photovoltaic Panels: A Case Study in an Educational Building
    Dhakal, Rabin
    Sedai, Ashish
    Paneru, Suman
    Yosofvand, Mohammad
    Moussal, Hanna
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2021, 11 (02): : 879 - 889
  • [47] Interactive decision analysis on sustainable urban development: Guilin case study
    Huang, JW
    Zhao, CJ
    [J]. 1998 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS, VOLS 1-5, 1998, : 4032 - 4037
  • [48] WEST BERKELEY PUBLIC LIBRARY: A CASE STUDY IN ZERO-NET ENERGY LIGHTING DESIGN
    Pierson, Max
    [J]. JOURNAL OF GREEN BUILDING, 2015, 10 (02): : 25 - 41
  • [49] A holistic design approach for residential net-zero energy buildings: A case study in Singapore
    Lan, Lan
    Wood, Kristin L.
    Yuen, Chau
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 50
  • [50] Integrated Building Design in Tropical Climates: Lessons Learned from the ENERPOS Net Zero Energy Building
    Garde, Francois
    Ottenwelter, Eric
    Bornarel, Alain
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 81 - 89