A biosensor based on immobilization of lactate oxidase in a PB-CTAB film for FIA determination of lactate in beer samples

被引:10
|
作者
Lowinsohn, Denise [1 ]
Bertotti, Mauro [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
关键词
lactate; biosensor; prussian blue modified electrodes; CTAB; FIA amperometric detection; beer;
D O I
10.1590/S0103-50532008000400005
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of the measurements. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 mmol L-1 lactate with a limit of detection of 0.84 mu mol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The usefulness of the method was demonstrated by determining lactate in beer samples and the results were in good agreement with those obtained by using a reference spectrophotometric enzyme method.
引用
收藏
页码:637 / 642
页数:6
相关论文
共 50 条
  • [21] Reagent-Less and Robust Biosensor for Direct Determination of Lactate in Food Samples
    Bravo, Iria
    Revenga-Parra, Monica
    Pariente, Felix
    Lorenzo, Encarnacion
    SENSORS, 2017, 17 (01):
  • [22] Amperometric enzyme electrode for L(+)-lactate determination using immobilized L(+)-lactate oxidase in poly(vinylferrocenium) film
    Aydin, G
    Çelebi, SS
    Özyörük, H
    Yildiz, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) : 8 - 12
  • [23] Development of a potentiometric biosensor based on nanostructured surface for lactate determination
    Lupu, A.
    Valsesia, A.
    Bretagnol, F.
    Colpo, P.
    Rossi, F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (02) : 606 - 612
  • [24] Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin film technology
    Pfeiffer, D
    Moller, B
    Klimes, N
    Szeponik, J
    BIOSENSORS & BIOELECTRONICS, 1997, 12 (06): : 539 - 550
  • [25] EVALUATION OF A BIOSENSOR AND COLUMN LACTATE OXIDASE IMMOBILIZATION FOR PHYSIOLOGICAL ANALYSIS USING FLOW-INJECTION AMPEROMETRY
    MATUSZEWSKI, W
    KOWALCZYK, J
    POLISH JOURNAL OF CHEMISTRY, 1995, 69 (09) : 1257 - 1265
  • [26] Development of a catalase based biosensor for alcohol determination in beer samples
    Akyilmaz, E
    Dinçkaya, E
    TALANTA, 2003, 61 (02) : 113 - 118
  • [27] Carrier-based immobilization of Aerococcus viridans L-lactate oxidase
    Luley-Goedl, Christiane
    Bruni, Margherita
    Nidetzky, Bernd
    JOURNAL OF BIOTECHNOLOGY, 2024, 382 : 88 - 96
  • [28] An amperometric biosensor based on lactate oxidase immobilized in laponite-chitosan hydrogel on a glassy carbon electrode. Application to the analysis of L-lactate in food samples
    Paz Zanini, Veronica
    Lopez de Mishima, Beatriz
    Solis, Velia
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (01): : 75 - 80
  • [29] Amperometric Biosensor Based on a Semipermeable Poly-Meta-Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate L-Lactate Determination in Blood Serum
    Berketa, Kseniia
    Buzhak, Anhelina
    Vakhovskyi, Yevhen
    Mruga, Daryna
    Sverstiuk, Andrii
    Soldatkina, Olha
    Lyubovych, Olha
    Marchuk, Olga
    Dzyadevych, Serhii
    Soldatkin, Oleksandr
    ELECTROANALYSIS, 2025, 37 (01)
  • [30] Dataset on fabrication of an improved L-lactate biosensor based on lactate oxidase/cMWCNT/CuNPs/PANI modified PG electrode
    Dagar, Kusum
    Pundir, C. S.
    DATA IN BRIEF, 2018, 17 : 1163 - 1167