Dumon stent placement via endotracheal tube

被引:11
|
作者
Nomori, H [1 ]
Horio, H [1 ]
Suemasu, K [1 ]
机构
[1] Saiseikai Cent Hosp, Dept Thorac Surg, Minato Ku, Tokyo 1080073, Japan
关键词
conventional endotracheal tube; Dumon stent; flexible bronchoscope; rigid bronchoscope; tracheobronchial stenosis;
D O I
10.1378/chest.115.2.582
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Dumon stent placement requires use of a technically difficult rigid bronchoscope. A recently developed technique for placing a Dumon stent introduced via a conventional endotracheal tube is detailed herein. Methods: The conventional endotracheal tube is inserted beyond the stenosis site; this procedure is observed with the use of a flexible bronchoscope with the patient undergoing general anesthesia. The Dumon stent is folded and inserted into the endotracheal tube and is introduced into the stenosis site with the use of a cylindrical-tipped stainless steel wire as a pusher. The endotracheal tube is withdrawn while the pusher is positioned to expand the stent at the stenosis site. Dumon stents of 12 to 16 mm in diameter mere put in place using the present method in 5 cases of tracheobronchial stenosis. Results: The mean time from endotracheal tube insertion to stent placement was 181 s. The present method positioned the Dumon stent more easily and safely than the original rigid bronchoscope because the endotracheal tube used was flexible. One patient, however, required a tracheostomy and surgical forceps to remove the stent 3 months after placement, Conclusion: While Dumon stent removal may require a rigid bronchoscope or tracheostomy, stents can be introduced without difficulty via a conventional endotracheal tube.
引用
收藏
页码:582 / 583
页数:4
相关论文
共 50 条
  • [21] 1313 Endotracheal Tube Size and Placement in Neonates
    J E Tan
    A Foran
    S Ryan
    Pediatric Research, 2010, 68 : 649 - 650
  • [22] Confirmation of blind endotracheal tube placement - Reply
    Capistrano, CL
    ANNALS OF EMERGENCY MEDICINE, 1996, 27 (01) : 101 - 101
  • [23] Confirmation of blind endotracheal tube placement - Comment
    Palmer, RB
    ANNALS OF EMERGENCY MEDICINE, 1996, 27 (01) : 100 - 101
  • [24] Tracheoscopy with the Rapiscope to verify endotracheal tube placement
    Ping, STJS
    Pittman, JA
    Hohm, SA
    Sherwood, MW
    JOURNAL OF CLINICAL ANESTHESIA, 2003, 15 (05) : 334 - 338
  • [25] CHECKING FOR CORRECT ENDOTRACHEAL-TUBE PLACEMENT
    PHILLIPS, G
    ANAESTHESIA AND INTENSIVE CARE, 1994, 22 (04) : 498 - 499
  • [26] Visualization of trachea to verify endotracheal tube placement
    Ping, STS
    Hohm, SA
    Talman, DJ
    ANESTHESIA AND ANALGESIA, 1997, 84 : S273 - S273
  • [27] DEPTH OF ENDOTRACHEAL-TUBE PLACEMENT IN NEONATES
    KOHELET, D
    GOLDBERG, A
    GOLDBERG, M
    JOURNAL OF PEDIATRICS, 1982, 101 (01): : 157 - 157
  • [28] ENDOTRACHEAL-TUBE PLACEMENT IN INFANTS - REPLY
    HELLER, RM
    COTTON, RB
    PEDIATRICS, 1986, 77 (01) : 132 - 132
  • [29] Placement of a Double-Lumen Endotracheal Tube
    Hao, David
    Saddawi-Konefka, Daniel
    Baker, Keith
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (27): : 2591 - 2592
  • [30] Placement of a Double-Lumen Endotracheal Tube
    Hao, David
    Saddawi-Konefka, Daniel
    Low, Sarah
    Alfille, Paul
    Baker, Keith
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (16):