An experimental investigation of the swirling flow in a tall-form counter current spray dryer

被引:18
|
作者
Francia, Victor [1 ,2 ]
Martin, Luis [2 ]
Bayly, Andrew E. [2 ]
Simmons, Mark J. H. [1 ]
机构
[1] Univ Birmingham, Sch Chem Engn, Birmingham B15 2TT, W Midlands, England
[2] Newcastle Innovat Ctr, Procter & Gamble R&D, Newcastle Upon Tyne, Tyne & Wear, England
基金
英国工程与自然科学研究理事会;
关键词
Spray drying; Vortex flow; Swirl decay; Friction; Downstream effects; PVC; TURBULENT FLOWS; PRECESSING VORTEX; PARTICLE FLOW; GAS; CYCLONE; DECAY; SIMULATIONS; MECHANISMS; PATTERNS;
D O I
10.1016/j.expthermflusci.2015.03.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work studies the air flow in a large swirl counter-current dryer using sonic anemometry. Air velocity and turbulence fields are reported at isothermal conditions and in the absence of particles. In a tall-form unit the structure of the flow is largely influenced by the design of the exit. A contraction originates a central jet and suppresses the formation of recirculation zones despite the vortex acquires a high swirl intensity Omega (i.e. 1 < Omega < 2). Access to a full scale tower has permitted to: (a) identify asymmetries owed to the design of inlet and exhaust ducts, (b) present the first detailed turbulence data in production units, characterized by a highly anisotropic field and the axial decay of the turbulence kinetic energy, (c) study the flow stability, identifying the precession of the vortex core and oscillations at a constant Strouhal number and (d) study the impact that a rough wall has in the strength of the swirl. This work presents the first clear evidence of significant friction in spray dryers. The swirl intensity Omega decays exponentially in the dryer at a rate between 0.08 and 0.09, much higher than expected in pipe flow and independent of Re in the range 10(5)-2.2 . 10(5). Production dryers have a large characteristic wall roughness due the presence of deposits, which explains the stronger friction and the discrepancies found in the past between data at full scale or clean laboratory or pilot scale units. It is essential to address this phenomenon in current numerical models, which are validated on laboratory or pilot scale facilities and ignore the role of deposits, thus causing an overprediction of the tangential velocity above 30-40%. (C) 2015 The Authors. Published by Elsevier Inc.
引用
收藏
页码:52 / 64
页数:13
相关论文
共 50 条
  • [21] CFD simulations of droplet and particle agglomeration in an industrial counter-current spray dryer
    Jaskulski, M.
    Wawrzyniak, P.
    Zbicinski, I.
    ADVANCED POWDER TECHNOLOGY, 2018, 29 (07) : 1724 - 1733
  • [22] Experimental analysis of counter-current spray drying
    Zbicinski, I
    Piatkowski, M
    INZYNIERIA CHEMICZNA I PROCESOWA, 2004, 25 (03): : 1855 - 1860
  • [23] A multistage spray drying model for zeolite 4A-water suspensions in a counter-current spray dryer
    Sagadin, G.
    Hribersek, M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 : 1220 - 1228
  • [24] Experimental investigation of atomization characteristics of swirling spray by ADN gelled propellant
    Guan, Hao-Sen
    Li, Guo-Xiu
    Zhang, Nai-Yuan
    ACTA ASTRONAUTICA, 2018, 144 : 119 - 125
  • [25] Experimental Investigation on Spray Characteristic of Pilot Stage in Triple Swirling Atomizer
    Xie Y.
    He W.
    Guo Z.-H.
    Tuijin Jishu/Journal of Propulsion Technology, 2023, 44 (02):
  • [26] Experimental Investigation of Counter-Current Flow in Downcomer of CAP1400
    Fei L.
    Zhang P.
    He D.
    Yuan H.
    Hu F.
    Cui L.
    Shen F.
    Liu L.
    Dong B.
    Hedongli Gongcheng/Nuclear Power Engineering, 2021, 42 (02): : 60 - 64
  • [27] An experimental investigation of lime juice drying in a pilot plant spray dryer
    Roustapour, OR
    Hosseinalipour, M
    Ghobadian, B
    DRYING TECHNOLOGY, 2006, 24 (02) : 181 - 188
  • [28] Experimental Investigations of the Stable Form of the Vortex Structure of a Swirling Flow
    Mitrofanova, O. V.
    Pozdeeva, I. G.
    Starovoitov, N. A.
    JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2025, 98 (01) : 219 - 229
  • [29] Computational investigation of air solid flow in a spray dryer for effluent treatment
    Singh, Sunil Kumar
    Ali, B. Ashraf
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2020, 97 (07) : 1142 - 1145
  • [30] Numerical and experimental investigation of swirling flow in a conical diffuser
    David, Stefan
    Pavel, Zubik
    Martin, Hudec
    Pavel, Rudolf
    EFM14 - EXPERIMENTAL FLUID MECHANICS 2014, 2015, 92