The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: an in vitro cadaveric study

被引:29
|
作者
Clavenna, Andrew L. [2 ]
Beutler, William J. [3 ]
Gudipally, Manasa [1 ]
Moldavsky, Mark [1 ]
Khalil, Saif [1 ]
机构
[1] Globus Med Inc, Res, Audubon, PA 19403 USA
[2] WB Carrell Clin, Dallas, TX 75231 USA
[3] Penn Spine Inst, Harrisburg, PA 17109 USA
来源
SPINE JOURNAL | 2012年 / 12卷 / 02期
关键词
Anterior plating; Cervical spacers; Posterior instrumentation; ACDF; Biomechanical; ANTERIOR CERVICAL DISKECTOMY; OF-THE-LITERATURE; INTERBODY FUSION; ESOPHAGEAL-PERFORATION; FIBULAR ALLOGRAFT; SCREW FIXATION; DISK DISEASE; FOLLOW-UP; SPINE; POLYETHERETHERKETONE;
D O I
10.1016/j.spinee.2012.01.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Anterior cervical plating increases stability and hence improves fusion rates to treat cervical spine pathologies, which are often symptomatic at multiple levels. However, plating is not without complications, such as dysphagia, injury to neural elements, and plate breakage. The biomechanics of a spacer with integrated plate system combined with posterior instrumentation (PI), in two-level and three-level surgical models, has not yet been investigated. PURPOSE: The purpose of the study was to biomechanically evaluate the multidirectional rigidity of spacer with integrated plate (SIP) at multiple levels as comparable to traditional spacers and plating. STUDY DESIGN: An in vitro cervical cadaveric model. METHODS: Eight fresh human cervical (C2-C7) cadaver spines were tested under pure moments of +/- 1.5 Nm on spine simulator test frame. Each spine was tested in intact condition, with only anterior fixation and with both anterior and PI. Range of motion (ROM) was measured using Optotrak Certus (NDI, Inc., Waterloo, Ontario, Canada) motion analysis system in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) at the instrumented levels (C3-C6). Repeated-measures analysis of variance was used for statistical analysis. RESULTS: All the surgical constructs showed significant reduction in motion compared with intact condition. In two-level fusion, SIP (C4-C6) construct significantly reduced ROM by 66.5%, 65.4%, and 60.3% when compared with intact in FE, LB, and AR, respectively. In three-level fusion, SIP (C3-C6) construct significantly reduced ROM by 65.8%, 66%, and 49.6% when compared with intact in FE, LB, and AR, respectively. Posterior instrumentation showed significant stability only in three-level fusion when compared with their respective anterior constructs. In both two-level and three-level fusion, SIP showed comparable stability to traditional spacer and plate constructs in all loading modes. CONCLUSIONS: The anatomically profiled spacer with integrated plate allows treatment of cervical disorders with fewer steps and less impact to cervical structures. In this biomechanical study, spacer with integrated plate construct showed comparable stability to traditional spacer and plate for two-level and three-level fusion. Posterior instrumentation showed significant effect only in three-level fusion. Clinical data are required for further validation of using spacer with integrated plate at multiple levels. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 25 条
  • [21] Do Translaminar Facet Screws Have the Same Stability as Pedicle Screws in Two-Level Anterior Lumbar Interbody Fusion? A Biomechanical Study
    Zhan, Ying
    Tian, Ding
    TURKISH NEUROSURGERY, 2012, 22 (05) : 630 - 633
  • [22] Comparison of plate-cage construct and stand-alone anchored spacer in the surgical treatment of three-level cervical spondylotic myelopathy: a preliminary clinical study
    Shi, Sheng
    Liu, Zu-De
    Li, Xin-Feng
    Qian, Lie
    Zhong, Gui-Bin
    Chen, Fang-Jing
    SPINE JOURNAL, 2015, 15 (09): : 1973 - 1980
  • [23] Cyclic loading of a stand-alone ALIF device with integrated screws in osteopenic and osteoporotic cadavers at level L5/S1: an in vitro cadaveric biomechanical study
    Jacob, Alina
    Heumann, Maximilian
    Zderic, Ivan
    Lauter-Born, Sascha
    Varga, Peter
    Haschtmann, Daniel
    Fekete, Tamas
    Gueorguiev, Boyko
    Loib, Markus
    SWISS MEDICAL WEEKLY, 2023, 153 : 14S - 14S
  • [24] A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up
    Yuqiao Chen
    Guohua Lü
    Bing Wang
    Lei Li
    Lei Kuang
    European Spine Journal, 2016, 25 : 2255 - 2262
  • [25] A comparison of anterior cervical discectomy and fusion (ACDF) using self-locking stand-alone polyetheretherketone (PEEK) cage with ACDF using cage and plate in the treatment of three-level cervical degenerative spondylopathy: a retrospective study with 2-year follow-up
    Chen, Yuqiao
    Lu, Guohua
    Wang, Bing
    Li, Lei
    Kuang, Lei
    EUROPEAN SPINE JOURNAL, 2016, 25 (07) : 2255 - 2262