Digital versus radiographic accuracy evaluation of guided implant surgery: an in vitro study

被引:12
|
作者
Yi, Chun [1 ,2 ,3 ,4 ]
Li, Sha [1 ,2 ,3 ,4 ]
Wen, Aonan [2 ,3 ,4 ,5 ]
Wang, Yong [2 ,3 ,4 ,5 ]
Zhao, Yijiao [2 ,3 ,4 ,5 ]
Zhang, Yu [1 ,2 ,3 ,4 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Oral Implantol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[3] Natl Engn Res Ctr Oral Biomat & Digital Med Devic, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[4] Beijing Key Lab Digital Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[5] Peking Univ, Sch & Hosp Stomatol, Ctr Digital Dent, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
关键词
Dental implant; Guided surgery; Accuracy; Digital registration; Cone-beam computed tomography; BEAM COMPUTED-TOMOGRAPHY; PRECISION; DENTISTRY; GUIDELINES; AGREEMENT;
D O I
10.1186/s12903-022-02585-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Cone-beam computed tomography (CBCT) is the most widely used method for postsurgical evaluation of the accuracy of guided implant surgery. However, the disadvantages of CBCT include radiation exposure, artifacts caused by metal implants, and high cost. Few studies have introduced a digital registration method to replace CBCT for evaluating the accuracy of guided surgery. The purpose of this study was to compare digital registration to conventional CBCT in terms of the capacity to evaluate the implant positioning accuracy of guided surgery. Materials and methods: This in vitro study included 40 acrylic resin models with posterior single mandibular tooth loss. Guided surgery software was used to determine the optimal implant position; 40 tooth-supported fully guided drilling templates were designed and milled accordingly. After the guided surgery, the accuracies of the surgical templates were evaluated by conventional CBCT and digital registration. For evaluation by conventional CBCT, postsurgical CBCT scans of the resin models were performed. The CBCT data were reconstructed and superimposed on the implant planning data. For digital registration, we constructed a virtual registration unit that consisted of an implant replica and a scan body. Next, we obtained postsurgical optical scans of resin models with the scan body. The postsurgical implant position was identified by superimposition of the registration unit and optical scan data. The implant planning data and postsurgical implant position data were superimposed; deviations were reported in terms of distance for implant entry/apex point and in terms of angle for the implant axis. Interclass correlation coefficients (ICCs) and Bland-Altman plots were used to analyze the agreement between the two evaluation methods. Results: The ICCs between the two methods were 0.986, 0.993, and 0.968 for the entry point, apex point, and angle, respectively; all were significantly greater than 0.75 (p < 0.001). Bland-Altman plots showed that the 95% limits of agreement of the differences were - 0.144 to +0.081 mm,-0.135 to+ 0.147 mm, and - 0.451 degrees to+ 0.729 degrees for the entry point, apex point, and angle, respectively; all values were within the maximum tolerated difference. Conclusion: Conventional CBCT and digital registration showed good agreement in terms of evaluating the accuracy of implant positioning using tooth-supported surgical templates.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Accuracy of Guided Implant Surgery in 25 Edentulous Arches: A Laboratory Observational Study
    Ben Yehuda, Daniel
    Weber, Hans-Peter
    Finkelman, Matthew
    Sicilia, Elena
    Muftu, Ali
    Chochlidakis, Konstantinos
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 718 - 724
  • [42] Accuracy evaluation of computer-guided implant surgery associated with prototyped surgical guides
    Cunha, Rodrigo Moreira
    Souza, Francisley Avila
    Hadad, Henrique
    Poli, Pier Paolo
    Maiorana, Carlo
    Carvalho, Paulo Sergio Perri
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 266 - 272
  • [43] Accuracy of a Template-Guided Implant Surgery System with a CAD/CAM-Based Measurement Method: An In Vitro Study
    Brandt, Jan
    Brenner, Martin
    Lauer, Hans-Christoph
    Brandt, Silvia
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 328 - 334
  • [44] Digital evaluation of the reproducibility of implant scanbody fit—an in vitro study
    Michael Stimmelmayr
    Jan-Frederik Güth
    Kurt Erdelt
    Daniel Edelhoff
    Florian Beuer
    Clinical Oral Investigations, 2012, 16 : 851 - 856
  • [45] Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study
    Alshawaf, Bahaa
    Weber, Hans-Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (08) : 835 - 842
  • [46] Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study
    Alkindi, Shaikha
    Hamdoon, Zaid
    Aziz, Ahmed M.
    JOURNAL OF DENTISTRY, 2024, 146
  • [47] Influence of intraoral scanning coverage on the accuracy of digital implant impressions - An in vitro study
    Wang, Zhen-yu
    Gong, Yu
    Liu, Fei
    Chen, Du
    Shen, Jie-fei
    JOURNAL OF DENTISTRY, 2024, 143
  • [48] The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery
    Smitkarn, Palita
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2019, 46 (09) : 949 - 957
  • [49] A multifunctional scannable mounting device for computer guided implant surgery: An in vitro study
    Rotenberg, Daniel
    Mayer, Yaniv
    Horwitz, Jacob
    Nov, Yuval
    Zigdon-Giladi, Hadar
    Gabay, Eran
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 221e1 - 221e8
  • [50] Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: an in vitro pilot study
    Chen, Jianping
    Bai, Xiaolei
    Ding, Yude
    Shen, Liheng
    Sun, Xin
    Cao, Ruijue
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)