Determination of N-(carboxymethyl)fumonisin B1 in corn products by liquid chromatography/electrospray ionization-mass spectrometry

被引:44
|
作者
Seefelder, W [1 ]
Hartl, M [1 ]
Humpf, HU [1 ]
机构
[1] Univ Wurzburg, Lehrstuhl Lebensmittelchem, D-97084 Wurzburg, Germany
关键词
fumonisins; N-(carboxymethyl)fumonisin B-1; liquid chromatography/electrospray; ionization-mass spectrometry; reducing sugars; corn products; mycotoxin;
D O I
10.1021/jf001429c
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
It is well-known that fumonisin B-1 (FB1) in corn meal decreases during baking, frying, and cooking, but it is still not exactly clear how heating affects the formation of N-(carboxymethyl)fumonisin B-1 (NCM-FB1), the reaction product of FB1 and reducing sugars. In model experiments corn grits were spiked with FB1 (2 mg/kg) and D-glucose (50 g/kg) or sucrose (50 g/kg) and manufactured into extrusion products at various temperatures (160-180 degreesC) and moisture levels (16-20%). A liquid chromatography/electrospray ionization-mass spectrometry method using isotopically labeled fumonisin FB1-d(6) as an internal standard was developed for the determination of NCM-FB1. For sample cleanup solid-phase C18 cartridges were used. The detection limit achieved with this method was 10 ng/g (signal-noise ratio = 3:1) using the protonated molecule [M + H](+) signal of NCM-FB1 (m/z 780) in the selected ion monitoring mode. Low concentrations of NCM-FB1 (29-97 ng/g) were detected in all samples spiked with D-glucose and FB1, whereas those spiked with FB1 and sucrose showed only NCM-FB1 in samples produced at 180 degreesC (NCM-FB1 = 27 ng/g). Various corn-containing food samples from the German market were analyzed for the presence of NCM-FB1, FB1, and hydrolyzed fumonisin B-1 (HFB1). All samples were contaminated with FB1 (22-194 ng/g) and HFB1 (5-247 ng/g), Six of nine samples contained NCM-FB1 in low concentrations ranging from 10 to 76 ng/g. From these data and the low toxicity of NCM-FB1 it can be concluded that the significance of NCM-FB1 in food seems to be a minor one.
引用
收藏
页码:2146 / 2151
页数:6
相关论文
共 50 条
  • [41] Study of Abl1 tyrosine kinase inhibitors by liquid chromatography-electrospray ionization-mass spectrometry
    Chen, Hui
    Adams, Erwin
    Van Schepdael, Ann
    TALANTA, 2013, 107 : 88 - 94
  • [42] Evaluation of fumonisin exposure by determination of fumonisin B1 in human hair and in Brazilian corn products
    Bordin, Keliani
    Rottinghaus, George E.
    Landers, Benjamin R.
    Ledoux, David R.
    Kobashigawa, Estela
    Corassin, Carlos H.
    Oliveira, Carlos A. F.
    FOOD CONTROL, 2015, 53 : 67 - 71
  • [43] Determination of deoxynivalenol and nivalenol in corn and wheat by liquid chromatography with electrospray mass spectrometry
    Plattner, RD
    Maragos, CM
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (01) : 61 - 65
  • [44] Trace analysis of antibacterial tylosin A, B, C and D in honey by liquid chromatography-electrospray ionization-mass spectrometry
    Nalda, MJN
    Yagüe, JLB
    Gómez, MTM
    Sevilla, JJJ
    del Nozal, JB
    Pascual, MH
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (03) : 405 - 413
  • [45] Identification and determination of fumonisin FB1 and FB2 in corn and corn products by high-performance liquid chromatography - Electrospray-ionization tandem mass spectrometry (HPLC-ESI-MS-MS)
    Lukacs, Z
    Schaper, S
    Herderich, M
    Schreier, P
    Humpf, HU
    CHROMATOGRAPHIA, 1996, 43 (3-4) : 124 - 128
  • [46] Performance liquid chromatography and liquid-chromatography-ejectrospray ionization-mass spectrometry
    Liu, SM
    Chen, KS
    Schiemann, W
    Strack, D
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (08) : 1023 - 1023
  • [47] Simultaneous identification of soyasaponins and isoflavones and quantification of soyasaponin Bb in soy products, using liquid chromatography/electrospray ionization-mass spectrometry
    Dalluge, JJ
    Eliason, E
    Frazer, S
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (12) : 3520 - 3524
  • [48] Determination of Ranolazine in Rat Plasma by Liquid Chromatography–Electrospray Ionization Mass Spectrometry
    J. Zhong
    X. Q. Liu
    Y. Chen
    X. P. Zhao
    Y. S. Wang
    G. J. Wang
    Chromatographia, 2006, 63 : 123 - 127
  • [49] Determination of diquat and paraquat in water by liquid chromatography (electrospray ionization) mass spectrometry
    Taguchi, VY
    Jenkins, SWD
    Crozier, PW
    Wang, DT
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) : 830 - 839
  • [50] Determination of procarbazine in human plasma by liquid chromatography with electrospray ionization mass spectrometry
    He, X
    Batchelor, TT
    Grossman, S
    Supko, JG
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (02): : 281 - 291