Voltage/current characteristics of high-current vacuum arc at a small gap length

被引:3
|
作者
Zalucki, Z
机构
[1] Poznań Univ. of Technology, Inst. of Electric Power Engineering, 60-965 Poznań
关键词
D O I
10.1007/BF01795147
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Measurements of are voltage for semiwave currents of the amplitude up to 13 kA and frequencies 0.9 kHz and 6.0 kHz were done for CuCr electrodes whose separtion was 2 mm. The obtained data were used to determine voltage/current and voltage-time characteristics of high-current vacuum are. They enabled to state as: a) The shape and values of are voltage during a sinusoidal current semiwave flow depend on the current amplitude and frequency. As the current amplitude increases the are voltage rises, and its shape changes from relatively low and quiet to high with considerable fluctuations of high frequency and amplitude (HAF). b) Are voltage at a given current instantaneous value i(a1) depends on the current waveform before reaching i(a1). The are voltage beyond the range of HAF occurrence, at the same instantaneous value of the sinusoidal current, is higher during the current increase than during its decrease and higher for higher current frequency. c) Mean are voltage and current value at the moment of HAF onset, rise with the increase of current peak and frequency. This article presents qualitative correlations between the measured are voltage and an expected discharge mode in the intercontact gap.
引用
收藏
页码:981 / 994
页数:14
相关论文
共 50 条
  • [41] Characteristics of high-current pulsed arc discharge
    Masugata, K
    Maekawa, H
    Yoshida, M
    Ishii, T
    Suzuki, T
    Yatsui, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1996, 35 (10): : 5487 - 5494
  • [42] Study on High-Current Vacuum Arc Characteristics Under Self-Generated Axial Magnetic Field of Contact at a Long Contact Gap for High-Voltage Vacuum Interrupters
    Cheng, Shaoyong
    Wang, Jimei
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (01) : 243 - 253
  • [43] Current constriction phenomena in high-current vacuum arc and its influence factors
    Wang, Lijun
    Jia, Shenli
    Zhang, Ling
    Yang, Dingge
    Shi, Zongqian
    ISDEIV 2008: PROCEEDINGS OF THE XXIIIRD INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, 2008, : 329 - 332
  • [44] High-Current Vacuum Arc Shunted by a Semiconductor Switch on Kiloampere Current Interruption
    Schneider, Anton V.
    Popov, Sergey A.
    Batrakov, Alexander V.
    Lavrinovich, Valery A.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (07) : 1235 - 1240
  • [45] Voltage-current characteristics of high-current glow discharges
    Takaki, K
    Taguchi, D
    Fujiwara, T
    APPLIED PHYSICS LETTERS, 2001, 78 (18) : 2646 - 2648
  • [46] POST-ARC CURRENT AFTER HIGH-CURRENT INTERRUPTION IN VACUUM.
    Yanabu, S.
    Kaneko, E.
    Tamagawa, T.
    Matsumoto, K.
    Homma, M.
    IEEE transactions on electrical insulation, 1984, EI-20 (04): : 739 - 744
  • [47] CURRENT-VOLTAGE CHARACTERISTICS OF THE VACUUM-ARC
    DROUET, MG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (02): : 102 - 102
  • [48] A High-Voltage and High-Current Triggered Vacuum Switch
    Yao, Xueling
    Chen, Jingliang
    Sun, Wei
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (10) : 2901 - 2905
  • [49] The Influence of an External Coaxial Magnetic Field on the Characteristics of a High-Current ARC in a Vacuum Switch
    A. V. Schneider
    S. A. Popov
    E. L. Dubrovskaya
    A. V. Batrakov
    Russian Physics Journal, 2019, 62 : 900 - 905
  • [50] The Influence of an External Coaxial Magnetic Field on the Characteristics of a High-Current ARC in a Vacuum Switch
    Schneider, A. V.
    Popov, S. A.
    Dubrovskaya, E. L.
    Batrakov, A. V.
    RUSSIAN PHYSICS JOURNAL, 2019, 62 (05) : 900 - 905