Comparative efficiency of contrast-enhanced colour Doppler ultrasound targeted versus systematic biopsy for prostate cancer detection

被引:50
|
作者
Mitterberger, Michael Josef [1 ]
Aigner, Friedrich [2 ]
Horninger, Wolfgang [1 ]
Ulmer, Hanno [3 ]
Cavuto, Silvio [4 ]
Halpern, Ethan J. [5 ]
Frauscher, Ferdinand [2 ]
机构
[1] Med Univ Innsbruck, Dept Urol, A-6020 Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
[3] Med Univ Innsbruck, Dept Med Stat Informat & Hlth Econ MSIG, A-6020 Innsbruck, Austria
[4] Natl Canc Inst, I-20133 Milan, Italy
[5] Thomas Jefferson Univ, Jefferson Prostate Diagnost Ctr, Philadelphia, PA 19107 USA
关键词
Prostate cancer; Prostate biopsy; Ultrasound; Contrast agents; IMPACT; DIAGNOSIS; YIELD;
D O I
10.1007/s00330-010-1860-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the efficiency of contrast-enhanced colour Doppler ultrasound (CECD-US) targeted biopsy versus systematic biopsy (SB) for PCa detection in 1,776 men. Retrospective, single-centre, diagnostic accuracy study from 2002 until 2006 in 1,776 male volunteers with a serum total PSA of 1.25 ng/ml or greater. In each patient five CECD-US targeted biopsies were performed in hypervascular areas in the peripheral zone during intravenous injection of a second-generation microbubble US contrast agent. Subsequently, another examiner performed ten SBs. The PCa detection rates for the two techniques were compared. Of 1,776 patients, cancer was detected in 559 patients (31%), including 476 of the 1,776 patients (27%) with CECD-US and 410 (23%) with SB (p < 0.001). The detection rate for CECD-US targeted biopsy cores (10.8% or 961 of 8,880 cores) was significantly better than for SB cores (5.1% or 910 of 17,760 cores, p < 0.001). Among patients with a positive biopsy for PCa, cancer was detected by CECD-US alone in 149 patients (27%) and by SB alone in 83 (15%) (p < 0.001). This study represents the largest clinical trial to date, demonstrating a significant benefit of CECD-US targeted biopsy relative to SB.
引用
收藏
页码:2791 / 2796
页数:6
相关论文
共 50 条
  • [31] Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts
    Swensson, Jordan
    Hill, Danielle
    Tirkes, Temel
    Fridell, Jonathan
    Patel, Aashish
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (05) : 1093 - 1097
  • [32] Dynamic contrast-enhanced ultrasound parametric imaging for the detection of prostate cancer
    Postema, Arnoud W.
    Frinking, Peter J. A.
    Smeenge, Martijn
    De Reijke, Theo M.
    De la Rosette, Jean J. M. C. H.
    Tranquart, Francois
    Wijkstra, Hessel
    BJU INTERNATIONAL, 2016, 117 (04) : 598 - 603
  • [33] FLASH REPLENISHMENT IMAGING WITH CONTRAST-ENHANCED ULTRASOUND FOR PROSTATE CANCER DETECTION
    Zola, Joseph C., Jr.
    Halpern, Ethan J.
    Forsberg, Flemming
    Gomella, Leonard G.
    Trabulsi, Edouard J.
    JOURNAL OF UROLOGY, 2009, 181 (04): : 828 - 829
  • [34] Contrast enhanced color Doppler targeted biopsy: Value of blood flow rating scale for prostate cancer detection
    Mitterberger, Michael
    Colleselli, Daniela
    Pelzer, Alexandre E.
    Hominger, Wolfgang
    Bartsch, Georg
    Pallwein, Leo
    Frauscher, Ferdinand
    JOURNAL OF UROLOGY, 2008, 179 (04): : 677 - 677
  • [35] Scar versus recurrence in breast cancer: Differentiation by contrast enhanced colour Doppler ultrasound
    Stuhrmann, M
    Schwarz, T
    Schietzel, M
    ULTRASCHALL IN DER MEDIZIN, 2001, 22 (01): : 2 - 6
  • [36] The influence of prostate volume on prostate cancer detection using a combined approach of contrast-enhanced ultrasonography-targeted and systematic grey-scale biopsy
    Colleselli, Daniela
    Bektic, Jasmin
    Schaefer, Georg
    Frauscher, Ferdinand
    Mitterberger, Michael
    Brunner, Andrea
    Schwentner, Christian
    Bartsch, Georg
    Horninger, Wolfgang
    Pelzer, Alexandre E.
    BJU INTERNATIONAL, 2007, 100 (06) : 1264 - 1267
  • [37] THE ROLE OF CONTRAST-ENHANCED ULTRASOUND TARGETED PROSTATE BIOPSY IN MEN WITH PREVIOUS NEGATIVE BIOPSY AND RISING PROSTATE-SPECIFIC ANTIGEN
    Ho, Henry
    Pallwein, Leo
    Horninger, Wolfgang
    Schaefer, Georg
    Bartsch, Georg
    Frauscher, Ferdinard
    JOURNAL OF UROLOGY, 2009, 181 (04): : 801 - 801
  • [38] COLOUR DOPPLER COMBINED WITH MICROBUBBLE CONTRAST AGENT ULTRASONOGRAPHY AND THE CANCER DETECTION RATE IN TRANSRECTAL SYSTEMATIC PROSTATE BIOPSY SAMPLING
    Taverna, Gianluigi
    Giusti, Guido
    Seveso, Mauro
    Benetti, Alessio
    Minuti, Francesco
    Grizzi, Fabio
    Graziotti, Pierpaolo
    JOURNAL OF UROLOGY, 2012, 187 (04): : E820 - E820
  • [39] Contrast-Enhanced Colour Doppler Ultrasound Scan (CEUS) in the Evaluation of Hemophilic Arthropathy
    Tagariello, G.
    Radossi, P.
    Cesari, S. .
    Sartori, R.
    Maschio, N.
    Tassinari, C.
    Risato, R.
    Scarpa, E.
    HAEMOPHILIA, 2012, 18 : 128 - 129
  • [40] Analysis of the application of contrast-enhanced ultrasound-guided prostate biopsy in early diagnosis of prostate cancer
    Zhang, Chundong
    Feng, Meicong
    Fang, Qinmao
    Deng, Heping
    Zhang, Weiwei
    Wu, Xia
    Zhang, Bo
    Guan, Yiman
    MINERVA MEDICA, 2022, 113 (06) : 1032 - 1034