A three-dimensional thermal model of the human cochlea for magnetic cochlear implant surgery

被引:1
|
作者
Esmailie, Fateme [1 ]
Francoeur, Mathieu [1 ]
Ameel, Tim [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Thermal trauma; Cochlear implant; Magnetic insertion; TEMPORAL BONE; INSERTION; TEMPERATURE; DIMENSIONS; THICKNESS; GLYCEROL; TEXTURE; HEARING; FORCE;
D O I
10.1016/j.ijheatmasstransfer.2021.121553
中图分类号
O414.1 [热力学];
学科分类号
摘要
In traditional cochlear implant surgery, physical trauma may occur during electrode array insertion. Magnetic guidance of the electrode array has been proposed to mitigate this medical complication. After insertion, the guiding magnet attached to the tip of the electrode array must be detached via a heating process and removed. This heating process may, however, cause thermal trauma within the cochlea. In this study, a validated three-dimensional finite element heat transfer model of the human cochlea is applied to perform an intracochlear thermal analysis necessary to ensure the safety of the magnet removal phase. Specifically, the maximum safe input power density to detach the magnet is determined as a function of the boundary conditions, heating duration, cochlea size, implant electrode array radius and insertion depth, magnet size, and cochlear fluid. A dimensional analysis and numerical simulations reveal that the maximum safe input power density increases with increasing cochlea size and the radius of the electrode array, whereas it decreases with increasing electrode array insertion depth and magnet size. The best cochlear fluids from the thermal perspective are perilymph and a soap solution. Even for the worst case scenario in which the cochlear walls are assumed to be adiabatic except at the round window, the maximum safe input power density is larger than that required to melt 1 mm(3) of paraffin bonding the magnet to the implant electrode array. By combining the outcome of this work with other aspects of the design of the magnetic insertion process, namely the magnetic guidance procedure and medical requirements, it will be possible to implement a thermally safe patient-specific surgical procedure. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Three-Dimensional Plotting and Printing of an Implant Drilling Guide: Simplifying Guided Implant Surgery
    Fluegge, Tabea Viktoria
    Nelson, Katja
    Schmelzeisen, Rainer
    Metzger, Marc Christian
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (08) : 1340 - 1346
  • [32] An Instrumented Cochlea Model for the Evaluation of Cochlear Implant Electrical Stimulus Spread
    Jiang, Chen
    Singhal, Shreya
    Landry, Thomas
    Roberts, Iwan
    de Rijk, Simone R.
    Brochier, Tim
    Goehring, Tobias
    Tam, Yu
    Carlyon, Robert
    Malliaras, George
    Bance, Manohar
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (07) : 2281 - 2288
  • [33] Three-dimensional image analysis of the mouse cochlea
    Wright, Graham D.
    Horn, Henning F.
    DIFFERENTIATION, 2016, 91 (4-5) : 104 - 108
  • [34] Three-dimensional imaging of the temporal bone using helical CT in cochlear implant patients
    Himi, T
    Kataura, A
    Sakata, M
    Odawara, Y
    Satoh, J
    Sawaishi, M
    COCHLEAR IMPLANT AND RELATED SCIENCES UPDATE, 1997, 52 : 96 - 99
  • [35] Three-Dimensional Finite Element Modeling of Cochlear Implant Induced Electrical Current Flows
    Chen, Kevin
    Li, Qing
    Li, Wei
    Lau, Howard
    Ruys, Andrew
    Carter, Paul
    2009 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE FOR MEASUREMENT SYSTEMS AND APPLICATIONS, 2009, : 5 - +
  • [36] Sensing and Three-dimensional OCT Imaging of The Cochlea and Temporal Bone: Image-Guided Cochlear Implantation
    Zhao, Mingtao
    Chien, Wade W.
    Iordachita, Iulian
    Huang, Yong
    Taylor, Russ
    Niparko, John
    Kang, Jin U.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565
  • [37] A three-dimensional human walking model
    Yang, Q. S.
    Qin, J. W.
    Law, S. S.
    JOURNAL OF SOUND AND VIBRATION, 2015, 357 : 437 - 456
  • [38] A Three-Dimensional Transient Thermal Model for Machining
    Islam, Coskun
    Lazoglu, Ismail
    Altintas, Yusuf
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (02):
  • [39] The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template
    Matta, Ragai-Edward
    Bergauer, Bastian
    Adler, Werner
    Wichmann, Manfred
    Nickenig, Hans-Joachim
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 804 - 808
  • [40] Evaluation of the Efficacy of Dexamethasone-Eluting Electrode Array on the Post-Implant Cochlear Fibrotic Reaction by Three-Dimensional Immunofluorescence Analysis in Mongolian Gerbil Cochlea
    Toulemonde, Philippine
    Risoud, Michael
    Lemesre, Pierre Emmanuel
    Beck, Cyril
    Wattelet, Jean
    Tardivel, Meryem
    Siepmann, Juergen
    Vincent, Christophe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)