A three-dimensional thermal model of the human cochlea for magnetic cochlear implant surgery

被引:1
|
作者
Esmailie, Fateme [1 ]
Francoeur, Mathieu [1 ]
Ameel, Tim [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84112 USA
基金
美国国家卫生研究院;
关键词
Thermal trauma; Cochlear implant; Magnetic insertion; TEMPORAL BONE; INSERTION; TEMPERATURE; DIMENSIONS; THICKNESS; GLYCEROL; TEXTURE; HEARING; FORCE;
D O I
10.1016/j.ijheatmasstransfer.2021.121553
中图分类号
O414.1 [热力学];
学科分类号
摘要
In traditional cochlear implant surgery, physical trauma may occur during electrode array insertion. Magnetic guidance of the electrode array has been proposed to mitigate this medical complication. After insertion, the guiding magnet attached to the tip of the electrode array must be detached via a heating process and removed. This heating process may, however, cause thermal trauma within the cochlea. In this study, a validated three-dimensional finite element heat transfer model of the human cochlea is applied to perform an intracochlear thermal analysis necessary to ensure the safety of the magnet removal phase. Specifically, the maximum safe input power density to detach the magnet is determined as a function of the boundary conditions, heating duration, cochlea size, implant electrode array radius and insertion depth, magnet size, and cochlear fluid. A dimensional analysis and numerical simulations reveal that the maximum safe input power density increases with increasing cochlea size and the radius of the electrode array, whereas it decreases with increasing electrode array insertion depth and magnet size. The best cochlear fluids from the thermal perspective are perilymph and a soap solution. Even for the worst case scenario in which the cochlear walls are assumed to be adiabatic except at the round window, the maximum safe input power density is larger than that required to melt 1 mm(3) of paraffin bonding the magnet to the implant electrode array. By combining the outcome of this work with other aspects of the design of the magnetic insertion process, namely the magnetic guidance procedure and medical requirements, it will be possible to implement a thermally safe patient-specific surgical procedure. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Constructing a three-dimensional electrical model of a living cochlear implant user's cochlea
    Malherbe, T. K.
    Hanekom, T.
    Hanekom, J. J.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2016, 32 (07)
  • [2] Experimental Validation of a Three-Dimensional Heat Transfer Model Within the Scala Tympani With Application to Magnetic Cochlear Implant Surgery
    Esmailie, Fateme
    Francoeur, Mathieu
    Ameel, Tim
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (09) : 2821 - 2832
  • [3] Heat transfer analysis in an uncoiled model of the cochlea during magnetic cochlear implant surgery
    Esmailie, Fateme
    Francoeur, Mathieu
    Ameel, Tim
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 154
  • [4] A comprehensive three-dimensional model of the cochlea
    Givelberg, E
    Bunn, J
    JOURNAL OF COMPUTATIONAL PHYSICS, 2003, 191 (02) : 377 - 391
  • [5] Thermal analysis of a cochlea during magnetically-guided cochlear implant surgery
    Esmailie, Fateme
    Francoeur, Mathieu
    Ameel, Tim A.
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [6] A Fast and Reliable Three-Dimensional Centerline Tracing: Application to Virtual Cochlear Implant Surgery
    Zamani, Majid
    Salkim, Enver
    Saeed, Shakeel R.
    Demosthenous, Andreas
    IEEE ACCESS, 2020, 8 : 167757 - 167766
  • [7] Three-dimensional analysis of electrode behavior in a human cochlear model
    Lim, YS
    Park, SI
    Kim, YH
    Oh, SH
    Kim, SJ
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (08) : 695 - 703
  • [8] Three-Dimensional Distribution of Cochlear Macrophages in the Lateral Wall of Cleared Cochlea
    Bae, Seong Hoon
    Kwak, Sang Hyun
    Yoo, Jee Eun
    Kim, Kyu Min
    Hyun, Young Min
    Choi, Jae Young
    Jung, Jinsei
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2021, 14 (02) : 179 - 184
  • [9] Bone conduction in a three-dimensional model of the cochlea
    Boehnke, Frank
    Arnold, Wolfgang
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2006, 68 (06): : 393 - 396
  • [10] The Feasibility of the Three-Dimensional Footswitch-Operated Robotic Arm Exoscope for Cochlear Implant Surgery
    Karinen, Eerika
    Iso-Mustajaervi, Matti
    Dietz, Aarno
    OTOLOGY & NEUROTOLOGY, 2023, 44 (08) : 786 - 790