摘要
Hydro-turbines are usually optimized for an operating points defined by speed, head, and discharge. At fixed-speed operation, limited deviations from head and discharge are allowed. However, to improve operational efficiency of hydro turbines with partial loads and varying heads, variable-speed turbine and generator operation offers an attractive solution. Variable-speed operation is achieved using a doubly-fed induction machine with power electronics. During hybrid power generation, stable interconnected system is achieved with pumped storage schemes as renewable energy sources are highly erratic, especially solar and wind. Application of doubly-fed induction machine in pumped storage scheme is equivalently significant in both motoring and generating modes. In practice, the doubly-fed induction machine experiences power quality problems, depending upon the location of pumped storage scheme and the length of the distribution feeder. The objective of this study is to analyze the effects of voltage unbalance on a 2.2-kW doubly-fed induction machine at motoring mode through computer simulations and laboratory experiments. The test results and subsequent analysis confer hidden damage of negative-sequence voltage and effects of positive-sequence voltage magnitude on the performance of doubly-fed induction machine, particularly ripples in torque and speed and reduction in overall machine efficiency, which makes pumped storage scheme economically unviable.
引用
收藏
页码:1291 / 1306
页数:16
相关论文
共 50 条
  • [41] Correlation Analysis Between Oscillation Mode and Impact Factor of Doubly-fed Induction Generator
    Miao J.
    Xie D.
    Wang X.
    Zhang Y.
    Zhu M.
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (17): : 5049 - 5060
  • [42] A doubly-fed induction machine differential drive model for automobiles
    Vicatos, NS
    Tegopoulos, JA
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (02) : 225 - 230
  • [43] Doubly-fed induction machine analysis for power flow control
    Raczkowski, BC
    Sauer, PW
    [J]. Proceedings: Electrical Insulation Conference and Electrical Manufacturing Conference, 2005, : 454 - 459
  • [44] BRUSHLESS CASCADED DOUBLY-FED INDUCTION MACHINE: MODELING AND SIMULATION
    Berriel, Ryan C. de O.
    Stephan, Richard M.
    Chabu, Ivan E.
    Ferreira, Antonio C.
    [J]. 2017 XIV BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP), 2017,
  • [45] A robustly stable PI controller for the doubly-fed induction machine
    Batlle, Carles
    Doria-Cerezo, Arnau
    Ortega, Romeo
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 2072 - +
  • [46] Control of doubly-fed induction machine in excitation and synchronization modes
    Peresada S.M.
    Blagodir V.O.
    [J]. Peresada, S.M. (sergei.peresada@gmail.com), 1600, Institute of Electrodynamics, National Academy of Sciences of Ukraine (2016): : 45 - 47
  • [47] Brushless doubly-fed AC excited induction machine drives
    Xie, L.
    Sun, Y.K.
    Wang, J.
    Du, C.
    Shen, X.Y.
    [J]. Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2001, 23 (02):
  • [48] Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system
    Akagi, H
    Sato, H
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (01) : 109 - 116
  • [49] Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance
    Hu, Jiabing
    He, Yikang
    Xu, Lie
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (07) : 847 - 856
  • [50] Performance evaluation of doubly-fed twin stator induction machine drive with voltage and current space vector control schemes
    Chilakapati, N
    Ramsden, VS
    Ramaswamy, V
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2001, 148 (03): : 287 - 292