Early Kidney Graft Size and Doppler Parameters Are Associated With Kidney Graft Function 1 Year After Transplantation

被引:9
|
作者
Buturovic-Ponikvar, J. [1 ]
Cerne, S. [1 ]
Arnol, M. [1 ]
Kandus, A. [1 ]
Ponikvar, R. [1 ]
Bren, A. [1 ]
机构
[1] Univ Med Ctr Ljubljana, Dept Nephrol, Ljubljana 1525, Slovenia
关键词
SYSTEMIC ATHEROSCLEROSIS; RESISTANCE INDEXES; ALLOGRAFT SURVIVAL; RENAL-ALLOGRAFTS; PREDICTION; RECIPIENTS; MASS;
D O I
10.1016/j.transproceed.2010.09.053
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The aim of this study was to assess the association of various ultrasonography (US) and Doppler parameters of kidney graft as measured at 1 month posttransplant with 1-year graft function. Materials and Methods. The study cohort included 125 adult recipients of deceased donor kidney transplantations between January 2006 and February 2009. All patients underwent an US-Doppler examination performed by a trained nephrologist at 1 month posttransplant using an Acuson-Siemens Sequoia 512. Graft length and intrarenal Doppler indices were measured at the midsegmental artery level. Relative graft size was calculated by dividing graft length with body mass index. Graft function was assessed at 1 year by estimated glomerular filtration rate (eGFR) using the 4-variable Modification of Diet in Real Disease study equation. Linear and logistic regression analyses were used to assess the relationship between US Doppler parameters and eGFR. Results. Univariate linear regression showed a significant correlation between eGFR at 1 year and graft length at 1 month (P = .009), relative graft length <0.50 cm per kg/m(2) (P = .004), resistance index >0.75 (P = .031), and end-diastolic velocity <9 cm/sec (P = .006). Logistic regression analyses showed that eGFR <60 mL/min/1.73 m(2) at 1 year was significantly associated with graft length <12 cm at 1 month (odds ratio [OR], 2.4; 95% confidence interval [CI], 1.16-4.92; P = .017), relative graft length <0.5 cm per kg/m(2) (OR, 2.54; 95% CI, 1.20-5.35; P = .014), resistance index >0.75 (OR, 2.86; 95% CI, 1.30-6.29; P = .009), and end-diastolic velocity <9 cm/sec (OR, 2.37; 95% CI, 1.01-5.56; P = .047). Conclusion. In this retrospective analysis, kidney transplant recipients with greater graft length at 1 month, specifically when standardized to body size, showed better graft function at 1 year posttransplantation. Higher intrarenal diastolic blood flow and lower resistance index at 1 month were also predictive of better graft function at 1 year.
引用
收藏
页码:4026 / 4029
页数:4
相关论文
共 50 条
  • [41] Early Tc-99m DTPA renal scan predicts graft function at 1 year after kidney transplantation
    Moon, Jang Bae
    Cho, Sang-Geon
    Choi, Soo Jin Na
    Park, Ki Seong
    Kim, Jahae
    Kang, Sae-Ryung
    Min, Jung-Joon
    Song, Ho-Chun
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [42] EARLY GRAFT REVISION AFTER KIDNEY TRANSPLANTATION IN PEDIATRIC PATIENTS
    Kowalski, Adam
    Ciopinski, Mateusz
    Rubik, Jacek
    Gastol, Piotr
    Kalicinski, Piotr
    PEDIATRIC TRANSPLANTATION, 2013, 17 : 92 - 93
  • [43] Unusual cause of early graft dysfunction after kidney transplantation
    Krumme, B
    Pisarski, P
    Blum, U
    Kirste, G
    Schollmeyer, P
    AMERICAN JOURNAL OF NEPHROLOGY, 1998, 18 (03) : 237 - 239
  • [44] Donor Dopamine Pretreatment and Graft Function After Kidney Transplantation
    Ball, Jonathan
    McAnulty, Greg
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 303 (03): : 231 - 231
  • [45] Complement Activation and Delayed Graft Function after Kidney Transplantation
    Arias-Cabrales, C.
    Perez-Saez, M.
    Riera, M.
    Gimeno, J.
    Benito, D.
    Redondo-Pachon, D.
    Buxeda, A.
    Burballa, A.
    Crespo, M.
    Pascual, J.
    Rodriguez, E.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2020, 20 : 667 - 667
  • [46] Delayed Graft Function After Kidney Transplantation: The Clinical Perspective
    Sharif, Adnan
    Borrows, Richard
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 62 (01) : 150 - 158
  • [47] Predictors of Hyperuricemia after Kidney Transplantation: Association with Graft Function
    Folkmane, Inese
    Tzivian, Lilian
    Folkmane, Elizabete
    Valdmane, Elina
    Kuzema, Viktorija
    Petersons, Aivars
    MEDICINA-LITHUANIA, 2020, 56 (03):
  • [48] PREGNANCY OUTCOME AFTER KIDNEY TRANSPLANTATION AND IMPACT ON GRAFT FUNCTION
    Alkot, Ahmed
    Sally, Samir
    Sakr, Mohamed
    Zahran, Mahmoud
    ElWasif, Salwa
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I969 - I969
  • [49] The consequences of delayed graft function (DGF) after kidney transplantation
    Hwang, Christine S.
    Tan, Jane C.
    Scandling, John D.
    Alfrey, Edward J.
    TRANSPLANT INTERNATIONAL, 2007, 20 : 233 - 234
  • [50] A "HIDDEN'' ENTITY: THE SLOW GRAFT FUNCTION AFTER KIDNEY TRANSPLANTATION
    Lochouarn, Marine
    Jeribi, Ahmed
    Dusseux, Emmanuelle
    Cassuto, Elisabeth
    TRANSPLANT INTERNATIONAL, 2012, 25 : 48 - 48