Early Kidney Graft Size and Doppler Parameters Are Associated With Kidney Graft Function 1 Year After Transplantation

被引:9
|
作者
Buturovic-Ponikvar, J. [1 ]
Cerne, S. [1 ]
Arnol, M. [1 ]
Kandus, A. [1 ]
Ponikvar, R. [1 ]
Bren, A. [1 ]
机构
[1] Univ Med Ctr Ljubljana, Dept Nephrol, Ljubljana 1525, Slovenia
关键词
SYSTEMIC ATHEROSCLEROSIS; RESISTANCE INDEXES; ALLOGRAFT SURVIVAL; RENAL-ALLOGRAFTS; PREDICTION; RECIPIENTS; MASS;
D O I
10.1016/j.transproceed.2010.09.053
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. The aim of this study was to assess the association of various ultrasonography (US) and Doppler parameters of kidney graft as measured at 1 month posttransplant with 1-year graft function. Materials and Methods. The study cohort included 125 adult recipients of deceased donor kidney transplantations between January 2006 and February 2009. All patients underwent an US-Doppler examination performed by a trained nephrologist at 1 month posttransplant using an Acuson-Siemens Sequoia 512. Graft length and intrarenal Doppler indices were measured at the midsegmental artery level. Relative graft size was calculated by dividing graft length with body mass index. Graft function was assessed at 1 year by estimated glomerular filtration rate (eGFR) using the 4-variable Modification of Diet in Real Disease study equation. Linear and logistic regression analyses were used to assess the relationship between US Doppler parameters and eGFR. Results. Univariate linear regression showed a significant correlation between eGFR at 1 year and graft length at 1 month (P = .009), relative graft length <0.50 cm per kg/m(2) (P = .004), resistance index >0.75 (P = .031), and end-diastolic velocity <9 cm/sec (P = .006). Logistic regression analyses showed that eGFR <60 mL/min/1.73 m(2) at 1 year was significantly associated with graft length <12 cm at 1 month (odds ratio [OR], 2.4; 95% confidence interval [CI], 1.16-4.92; P = .017), relative graft length <0.5 cm per kg/m(2) (OR, 2.54; 95% CI, 1.20-5.35; P = .014), resistance index >0.75 (OR, 2.86; 95% CI, 1.30-6.29; P = .009), and end-diastolic velocity <9 cm/sec (OR, 2.37; 95% CI, 1.01-5.56; P = .047). Conclusion. In this retrospective analysis, kidney transplant recipients with greater graft length at 1 month, specifically when standardized to body size, showed better graft function at 1 year posttransplantation. Higher intrarenal diastolic blood flow and lower resistance index at 1 month were also predictive of better graft function at 1 year.
引用
收藏
页码:4026 / 4029
页数:4
相关论文
共 50 条
  • [1] Kidney graft functionality 1 year after kidney transplantation
    Hernandez-Rivera, Juan C. H.
    Espinoza-Perez, Ramon
    Cruz-Santiago, Jose
    Rodriguez-Gomez, Raul
    Meza-Jimenez, Guillermo
    Cancino-Lopez, Jorge D.
    Cruz-Lopez, Martha
    Juana Perez-Lopez, M.
    Santos-Caballero, Marlene
    Salazar-Mendoza, Mariana
    Paniagua-Sierra, Ramon
    CIRUGIA Y CIRUJANOS, 2022, 90 (01): : 90 - 99
  • [2] Impact of delayed graft function on doppler ultrasound parameters in the early period after kidney transplantation.
    Romozi, Karmen
    Arnol, Miha
    Pajek, Jernej
    Gubensek, Jakob
    Premru, Vladimir
    Buturovic-Ponikvar, Jadranka
    Ales-Rigler, Andreja
    TRANSPLANTATION, 2024, 108 (09) : 603 - 603
  • [3] Hyperparathyroidism at 1 year after kidney transplantation is associated with graft loss
    Crepeau, Philip
    Chen, Xiaomeng
    Udyavar, Rhea
    Morris-Wiseman, Lilah F.
    Segev, Dorry L.
    McAdams-DeMarco, Mara
    Mathur, Aarti
    SURGERY, 2023, 173 (01) : 138 - 145
  • [4] Doppler Ultrasonographic Assessment of Early Changes in Kidney Graft Size and Resistive Index and Their Predictive Role on 1-Year Graft Function
    Mohammadi, A.
    Biniaz, F.
    Nikoobakht, M. R.
    Barbari, G. R.
    TRANSPLANTATION PROCEEDINGS, 2013, 45 (01) : 172 - 174
  • [5] RISK FACTORS FOR LOW GRAFT FUNCTION AT 1 YEAR AFTER KIDNEY TRANSPLANTATION
    Lee, Chang Hun
    Jung, Cheol Woong
    Gwon, Jun Gyo
    Kim, Myung Gyu
    TRANSPLANTATION, 2020, 104 (09) : S418 - S418
  • [6] CONNECTION BETWEEN COAGULATION PARAMETERS AND GRAFT FUNCTION IN EARLY PERIOD AFTER KIDNEY TRANSPLANTATION
    Pawlicki, Jacek
    Cierpka, Lech
    Krol, Robert
    TRANSPLANT INTERNATIONAL, 2009, 22 : 297 - 297
  • [7] Comparison of early renal function parameters for the prediction of 5-year graft survival after kidney transplantation
    Schnuelle, Peter
    Gottmann, Uwe
    Koeppel, Hannes
    Brinkkoetter, Paul Thomas
    Krzossok, Stefan
    Weiss, Johannes
    Schmitt, Wilhelm
    Yard, Benito A.
    Schwarzbach, Matthias Heinrich Martin
    Post, Stefan
    van der Woude, Fokko Johannes
    Birck, Rainer
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (01) : 235 - 245
  • [8] Kidney graft function after pancreas transplantation
    Tanchanco, Roberto
    Krishnamurthi, Venkatesh
    Fatica, Richard
    Nurko, Saul
    Winans, Charles
    Duclos, Alain
    Wee, Alvin
    Lard, Michelle
    Poggio, Emilio D.
    XENOTRANSPLANTATION, 2007, 14 (05) : 522 - 523
  • [9] NGAL IS A PREDICTOR OF GRAFT FUNCTION ONE YEAR AFTER KIDNEY TRANSPLANTATION?
    Maria Serna-Higuita, Lina
    Fredy Nieto-Rios, John
    Ocampo-Kohn, Catalina
    Aristizabal-Alzate, Arbey
    Dario Giraldo-Ramirez, Nelson
    Alejandra Rojano-Held, Nury
    Alberto Jaimes-Barragan, Fabian
    Adolfo Zuluaga-Valencia, Gustavo
    TRANSPLANT INTERNATIONAL, 2015, 28 : 717 - 717
  • [10] Effect of steroid avoidance on early graft function after kidney transplantation
    Roozrokh, HC
    Chen, L
    Scandling, JD
    Momsen, A
    Tan, J
    Busque, S
    AMERICAN JOURNAL OF TRANSPLANTATION, 2004, 4 : 354 - 354