The Use of Wavelets for the Monitoring and Diagnostic of Surface State of HV Polluted Insulators

被引:0
|
作者
Chaou, A. K. [1 ]
Mekhaldi, A. [1 ]
Moula, B. [1 ]
Teguar, M. [1 ]
机构
[1] Ecole Natl Polytech Alger, Lab Rech Electrotech, 10 Ave Hassen Badi,BP 182, El Harrach 16200, Alger, Algeria
关键词
Insulator pollution; Continuous Wavelet Transform; Discret Wavelet Transform; applied voltage; leakage current; Multi-Resolution Analysis; diagnostic; monitoring; FLASHOVER;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to ensure the continuity and the quality of electrical energy distribution, the diagnostic of polluted insulators is of utmost importance. For this purpose, a new performance monitoring methodology is proposed in this paper. Once acquisition of the applied voltage and the leakage current signals is carried out on a plan insulator model under uniform and non-uniform pollutions, the continuous (CWT) and discrete (DWT) wavelet transforms are performed. In case of a uniform pollution, the CWT with its time-scale analysis allows to characterize the state of the insulator surface by detecting the apparition of electrical discharges from the applied voltage waveform. While for a non-uniform pollution configuration, the DWT through its multi-resolution analysis allows us to predict the occurrence of the partial arcs phenomenon on the insulator surface based on the leakage current waveform. Through this work, the effectiveness of the wavelet technique has been highlighted as a new tool for the diagnostic and monitoring of polluted insulators performance.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Boundary conditions and surface state spectra in topological insulators
    V. V. Enaldiev
    I. V. Zagorodnev
    V. A. Volkov
    JETP Letters, 2015, 101 : 89 - 96
  • [32] A new approach to the design of surface subsystems of polymeric insulators for HV and MV apparatus under AC voltage
    Montanari, Gian Carlo
    Nath, Debasish
    Cambareri, Pasquale
    HIGH VOLTAGE, 2023, 8 (04) : 651 - 658
  • [34] On-line monitoring system on measuring leakage current near HV side for electrical transmission line insulators
    Zhao, Hanbiao
    Lin, Hui
    Xie, Lili
    Deng, Zhenglong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2004, 28 (22): : 78 - 82
  • [35] Diagnostic of Pre-breakdown State of Polymeric Insulators by the Thermovision Method
    Gefle, O. S.
    Lebedev, S. M.
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 647 - 650
  • [36] Comparison of Surface Leakage Current between Clean and Polluted Insulators under Dry Weather Condition
    Sakai, Yasuhiro
    Ninose, Takuya
    Murase, Hiroshi
    Yoda, Masayuki
    Sawa, Goro
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 41 - 41
  • [37] Use of Wavelet Transform to Analyze Leakage Current of Silicone Rubber Insulators Under Polluted Conditions
    Shaukat, Shahtaj
    Arshad
    Shah, Wahab Ali
    2022 2ND INTERNATIONAL CONFERENCE OF SMART SYSTEMS AND EMERGING TECHNOLOGIES (SMARTTECH 2022), 2022, : 118 - 123
  • [38] DISCUSSION ON NEW DESIGNS FOR HV INSULATORS USING SYNTHETIC MATERIALS AND SUPPRESSION OF INSULATOR FLASHOVER BY RESISTIVE SURFACE FILMS
    CLARK, CHW
    NACKE, H
    LAMBETH, PJ
    DEY, P
    NICHOLSO.JA
    MALES, RJ
    BIRD, TR
    BILLINGS, MJ
    WILKINS, R
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1967, 114 (07): : 946 - &
  • [39] Design of real-time operating state monitoring system for HV breaker
    Du, Ling-Yan
    Wang, Zhen-Hao
    Wang, Gang
    Li, Guo-Qing
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2006, 26 (01): : 58 - 61
  • [40] Surface State Magnetization and Chiral Edge States on Topological Insulators
    Zhang, Fan
    Kane, C. L.
    Mele, E. J.
    PHYSICAL REVIEW LETTERS, 2013, 110 (04)