Three-dimensional reconstruction of an asymmetric vessel phantom using two x-ray projections

被引:0
|
作者
Gopal, A [1 ]
Hoffmann, K [1 ]
Ionita, C [1 ]
Chityala, R [1 ]
Rudin, S [1 ]
Bednarek, D [1 ]
Wu, Y [1 ]
Dinu, P [1 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Sch Med & Biomed Sci, Buffalo, NY 14260 USA
关键词
D O I
10.1118/1.1998638
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Vascular lumen shape often predicts potential lumen occlusion and inadequate blood supply. Three‐dimensional (3D) lumen information can facilitate diagnosis and interventional therapies. We present a technique for 3D reconstruction of asymmetric vessel lumens using two x‐ray projections. Method and Materials: Images were acquired of a contrast‐filled vessel phantom with an asymmetric lesion. For two‐view reconstruction, lumen diameters, lesion geometric characteristics in each view, and correspondence between views were determined using previously described methods. Intensity profiles across the vessel lumen were extracted along epipolar lines. The profiles were fit using an elliptical model, and the deviation from ellipticity was taken to correspond to intruding plaque. The fitted profiles from the two views were used to generate elliptical cross sections, and the plaque information was used to deform these cross sections asymmetrically. The 3D lumen was created by combining individual 2D cross sections along the vessel length. To verify the method, 3D reconstructions were obtained in two ways from a set of digital subtraction angiography (DSA) images of the phantom obtained using a high‐resolution microangiographic detector (43 micron pixels): (a) using two orthogonal projections and our two‐view method, and (b) using 180 projections and a Feldkamp algorithm. The two reconstructed lumens were superimposed and the root‐mean‐square (RMS) distance between the lumen boundaries and percent overlap of the lumen volumes were calculated. Results: The RMS distance between the boundaries of the two‐view and the micro‐CT reconstructed lumens was less than 0.2 mm over the entire length of the vessel which had a diameter of 3.6 mm in non‐lesion segments; the volume overlap was 94%. Conclusion: Accurate 3D reconstruction of an asymmetrically stenosed vessel lumen was obtained using two radiographic projections as verified by comparison with microangiographic cone‐beam CT reconstruction. Supported by NIH EB002873, HL52567, NS43924 and Toshiba Medical Systems Corporation. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2157 / 2157
页数:1
相关论文
共 50 条
  • [21] Reconstruction of crystal shapes by X-ray nanodiffraction from three-dimensional superlattices
    Meduna, Mojmir
    Falub, Claudiu V.
    Isa, Fabio
    Chrastina, Daniel
    Kreiliger, Thomas
    Isella, Giovanni
    von Kaenel, Hans
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 2030 - 2037
  • [22] Three-dimensional x-ray diffraction nanoscopy
    Nikulin, Andrei Y.
    Dilanian, Ruben A.
    Zatsepin, Nadia A.
    Muddle, Barry C.
    [J]. INSTRUMENTATION, METROLOGY, AND STANDARDS FOR NANOMANUFACTURING II, 2008, 7042
  • [23] The X-ray three-dimensional structure of avidin
    Rosano, C
    Arosio, P
    Bolognesi, M
    [J]. BIOMOLECULAR ENGINEERING, 1999, 16 (1-4): : 5 - 12
  • [24] Three-dimensional reconstruction of human nipple using refraction-contrast X-ray computed tomography
    Sunaguchi, Naoki
    Shimao, Daisuke
    Ichihara, Shu
    Mori, Kensaku
    Yuasa, Tetsuya
    Ando, Masami
    [J]. 13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [25] Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)
    da Silva, Alessandro Márcio Hakme
    Alves, José Marcos
    da Silva, Orivaldo Lopes
    da Silva Junior, Nelson Ferreira
    [J]. Revista Brasileira de Engenharia Biomedica, 2014, 30 (02): : 93 - 101
  • [26] Application of a pnCCD in X-ray diffraction:: a three-dimensional X-ray detector
    Leitenberger, Wolfram
    Hartmann, Robert
    Pietsch, Ullrich
    Andritschke, Robert
    Starke, Ines
    Strueder, Lothar
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 (05) : 449 - 457
  • [27] Combining X-ray and Three-Dimensional Scanning of Sawlogs - Comparison between One and Two X-ray Directions
    Skog, Johan
    Oja, Johan
    [J]. 2009 PROCEEDINGS OF 6TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS (ISPA 2009), 2009, : 353 - 358
  • [28] Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion
    Volegov, P. L.
    Batha, S. H.
    Fittinghoff, D. N.
    Danly, C. R.
    Geppert-Kleinrath, V
    Wilde, C. H.
    Zylstra, A. B.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (03):
  • [29] Three-Dimensional Tumor Position Estimation Using Image Features On Orthogonal KV X-Ray Projections: Comparison of Two Feature Extraction Algorithms
    Anbo, S.
    Nakamura, M.
    Mukumoto, N.
    Ono, T.
    Mizowaki, T.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E307 - E307
  • [30] Three-dimensional imaging of acoustic phonons using an X-ray laser
    Clark, J.
    Robinson, I.
    [J]. ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2014, 70 : C288 - C288