Optimization of ultrasound contrast agent for high frequency ultrasound molecular imaging using subharmonic oscillation

被引:1
|
作者
Daeichin, V. [1 ]
Kooiman, K. [1 ]
Skachkov, I. [1 ]
Bosch, J. G. [1 ]
van der Steen, A. F. W. [1 ,2 ]
de Jong, N. [1 ,2 ]
机构
[1] Erasmus MC, Thoraxctr, Biomed Engn, Rotterdam, Netherlands
[2] Delft Univ Technol, Delft, Netherlands
关键词
ultrasound contrast agent; microbubble; subharmonic; high frequency ultrasound; ENCAPSULATED MICROBUBBLES;
D O I
10.1109/ULTSYM.2014.0438
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound molecular imaging visualizes disease biomarkers using targeted ultrasound contrast agents (t-UCA). Different lipids result in UCA with different acoustic behavior. In this study, subharmonic (SH) response of MicroMarker UCA and four homemade UCA with different lipid coatings were compared in vitro with a high frequency ultrasound system (Vevo 2100 with MS250 probe). UCA with different size distribution were made with DSPC (UCA A and C) or DPPC (UCA B and D) as main lipid by sonication or Vialmix. We transmitted long bursts (20-cycle, 30 MHz, 10% power, MS250 probe) with pulse inversion sequence for optimized SH imaging. The effect of the UCA concentration on SH imaging was tested using two concentrations: 8.0x10(6) and 4.0x10(5) microbubbles per milliliter. For A, B and D type UCA, attenuation effect is dominant at high concentration. MicroMarker and C type UCA had the highest and most spatially homogeneous distribution of SH response throughout the entire UCA area at high concentration. SH amplitude of MicroMarker dropped about 11 dB when UCA concentration was reduced by a factor of 20. For this low concentration, SH amplitude of B type UCA was 10 dB higher than that for MicroMarker and was homogeneous throughout the UCA area. We showed that for 30 MHz transmit frequency, at low concentration of UCA, DPPC microbubbles have higher SH response than DSPC ones and at high concentration, smaller bubbles (MicroMarker and C) produced the most homogeneous SH responses. Our results suggest that for molecular imaging applications where UCA concentration is low, our B-type and MicroMarker UCA are suitable choices for SH imaging.
引用
收藏
页码:1766 / 1769
页数:4
相关论文
共 50 条
  • [1] Molecular imaging with targeted contrast agents and high frequency ultrasound
    van Wamel, Annemieke
    Celebi, Muzaffer
    Hossack, John A.
    Backer, Joseph M.
    Backer, Marina V.
    Ley, Klaus
    de Jong, Nico
    Klibanov, Alexander L.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 961 - +
  • [2] Molecular imaging using a site-targeted ultrasound contrast agent
    Marsh, JN
    Hall, CS
    Abendschein, DR
    Scherrer, DE
    Scott, MJ
    Fuhrhop, RJ
    Gaffney, PJ
    Wickline, SA
    Lanza, GM
    [J]. 1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1713 - 1716
  • [3] Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
    Denbeigh, Janet M.
    Nixon, Brian A.
    Puri, Mira C.
    Foster, F. Stuart
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (97):
  • [4] Subharmonic contrast intravascular ultrasound for vasa vasorum imaging
    Goertz, David E.
    Frijlink, Martijn E.
    Tempel, Dennie
    Bhagwandas, Vijay
    Gisolf, Andries
    Krams, Robert
    de Jong, Nico
    van der Steen, Antonius F. W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (12): : 1859 - 1872
  • [5] Ultrasound Contrast Agents and Ultrasound Molecular Imaging
    Wen, Qiaonong
    Wan, Suiren
    Liu, Zengli
    Xu, Shuang
    Wang, Hairui
    Yang, Biao
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (01) : 190 - 209
  • [6] Ultrasound Contrast Agents For Ultrasound Molecular Imaging
    Tranquart, F.
    Arditi, M.
    Bettinger, T.
    Frinking, P.
    Hyvelin, J. M.
    Nunn, A.
    Pochon, S.
    Tardy, I.
    [J]. ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2014, 52 (11): : 1268 - 1276
  • [7] Active control of subharmonic response of ultrasound contrast agent microbubbles
    Faez, T.
    Renaud, G.
    Defontaine, M.
    Calle, S.
    De Jong, N.
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 172 - 175
  • [8] Subharmonic resonance of phospholipid coated ultrasound contrast agent microbubbles
    Yusefi, Hossein
    Helfield, Brandon
    [J]. ULTRASONICS SONOCHEMISTRY, 2024, 102
  • [9] A stimulus-responsive contrast agent for ultrasound molecular imaging
    Borden, Mark A.
    Zhang, Hua
    Gillies, Robert J.
    Dayton, Paul A.
    Ferrara, Katherine W.
    [J]. BIOMATERIALS, 2008, 29 (05) : 597 - 606
  • [10] Subharmonic contrast intravascular ultrasound
    Goertz, David E.
    Frijlink, Martijn E.
    Tempel, Dennie
    Krams, Robert
    de Jong, Nico
    van der Steen, Antonius F. W.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1065 - 1068