Solutions for enhancement of energy and exergy efficiencies in air handling units

被引:85
|
作者
Liu, Wanli [1 ,2 ]
Kalbasi, Rasool [3 ]
Afrand, Masoud [4 ,5 ]
机构
[1] China Univ Min & Technol, Sch Mech & Elect Engn, Xuzhou 210008, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Jiangsu Collaborat Innovat Ctr Intelligent Min Eq, Xuzhou 210008, Jiangsu, Peoples R China
[3] Islamic Azad Univ, Dept Mech Engn, Najafabad Branch, Najafabad, Iran
[4] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
关键词
Air handling unit; Exergy analysis; Irreversibility; Air-to-air heat exchanger; Cost saving; MODEL-PREDICTIVE CONTROL; HEAT-RECOVERY; HVAC SYSTEMS; MULTIOBJECTIVE OPTIMIZATION; PERFORMANCE; TECHNOLOGIES; VENTILATION; STRATEGIES; DESIGN; PUMP;
D O I
10.1016/j.jclepro.2020.120565
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, five layouts of using air-to-air heat exchangers (AAHE) were added in the Air Handling Unit (AHU) to diminish the cooling and heating coils energy usage through the energetic and exergetic analysis approach. In the first, second, and third techniques, the main focus is on cooling coil energy usage reduction. In the fourth and fifth layouts, new designs of using two AAHEs (i.e., primary and secondary units) have been incorporated to diminish simultaneously the energy demand of coils. The results showed if the objective function is defined to have the least cooling coil power, the fourth layout, and if the objective function is the lowest heating coil load, the fifth layout is recommended. In all layouts, installation of the AAHE reduced the irreversibility. In the best layout, AHU energy demand diminished by 23.68% which consequently improved the first law efficiency by 31.29%. Similarly, total exergy losses reduced by 26.58% and the second law efficiency improved by 11.79%. Calculations on cost analysis revealed that the least payback time and highest cost saving referred to first and fourth layouts, respectively. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Performance evaluation of solar air heater for various artificial roughness geometries based on energy, effective and exergy efficiencies
    Gupta, M. K.
    Kaushik, S. C.
    RENEWABLE ENERGY, 2009, 34 (03) : 465 - 476
  • [42] Effects of the dissimilarity of water depth on energy and exergy efficiencies and productivity of solar energy
    Yadav, Rakesh Kumar
    Kumar, Mukesh
    Singh, Jay
    Singh, Desh Bandhu
    Kumar, Navneet
    INTERNATIONAL JOURNAL OF EXERGY, 2022, 38 (03) : 333 - 345
  • [43] An estimation of the energy and exergy efficiencies for the energy resources consumption in the transportation sector in Malaysia
    Saidur, R.
    Sattar, M. A.
    Masjuki, H. H.
    Ahmed, S.
    Hashim, U.
    ENERGY POLICY, 2007, 35 (08) : 4018 - 4026
  • [44] Robust Sliding Mode Control of Air Handling Unit for Energy Efficiency Enhancement
    Shah, Awais
    Huang, Deqing
    Chen, Yixing
    Kang, Xin
    Qin, Na
    ENERGIES, 2017, 10 (11):
  • [46] Synergization of air handling units for high energy efficiency in office buildings: The theory and analysis
    Yu, Yuebin
    Liu, Mingsheng
    Li, Haorong
    Yu, Daihong
    Loftness, Vivian
    ENERGY AND BUILDINGS, 2012, 45 : 264 - 273
  • [47] Energy usage reduction in an air handling unit by incorporating two heat recovery units
    Goldanlou, Aysan Shahsavar
    Kalbasi, Rasool
    Afrand, Masoud
    JOURNAL OF BUILDING ENGINEERING, 2020, 32 (32)
  • [48] Torsional resonance analysis in air handling units
    Zeng, PW
    JOURNAL OF SOUND AND VIBRATION, 2001, 248 (03) : 557 - 566
  • [49] Re: Fresh air-handling units
    Gatley, Don
    ASHRAE JOURNAL, 2007, 49 (03) : 20 - 20
  • [50] Torsional resonance analysis in air handling units
    Zeng, PW
    SOUND AND VIBRATION, 2001, 35 (05): : 18 - 22