Can Location of Stiffness Measurement Impact Spleen 2-Dimensional Shear Wave Elastography Measurement?

被引:0
|
作者
Song, Jinzhen [1 ,2 ]
Li, Jiawu [2 ]
Luo, Yan [2 ]
Lu, Qiang [2 ]
机构
[1] Qingdao Univ, Affiliated Hosp, Dept Abdominal Ultrasound, Qingdao, Peoples R China
[2] Sichuan Univ, Dept Ultrasound, West China Hosp, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
关键词
spleen; ultrasonography; 2-dimensional shear wave elastography; portal hypertension; TRANSIENT ELASTOGRAPHY; PORTAL-HYPERTENSION; LIVER STIFFNESS; NONINVASIVE ASSESSMENT; ULTRASOUND; RECOMMENDATIONS; RELIABILITY; DIAGNOSIS; CIRRHOSIS; FIBROSIS;
D O I
10.1097/RUQ.0000000000000602
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultrasound-based spleen elastography is a promising surrogate to predict portal hypertension noninvasively. In contrast to defined standards for liver stiffness measurement, the standardized examination procedures for 2-dimensional (2D) shear wave elastography spleen elastography have not been established yet. The aim was to investigate the impact of location of stiffness measurement on 2D shear wave elastography spleen stiffness measurement (SSM). Patients with splenomegaly were enrolled. Both B-mode ultrasound and elastography of spleen were performed. For SSM, 3 regions were chosen for spleen measurement: lower pole region, central region, and the region between lower pole and center. Mean SSM value, success rate, and reliability predicators (standard deviation, standard deviation/mean, size of region of interest) were assessed. A total of 124 patients were included. For mean SSM value, there were no significant differences among 3 regions. Spleen stiffness measurement success rate in lower pole region, central region, and the region between them was 63.7% (79), 91.1% (113), and 78.2% (97), respectively. The success rate in the central region was significantly higher than that in the other 2 regions (P < 0.05). Reliability in the central region was also highest among the 3 regions. Location of stiffness measurement has a limited effect on SSM. Changing location of measurement will not influence mean stiffness value in spleen.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [41] Evaluation of Neonatal Brain Parenchyma Using 2-Dimensional Shear Wave Elastography
    Albayrak, Eda
    Kasap, Tuba
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (04) : 959 - 967
  • [42] Intra-System Reliability Assessment of 2-Dimensional Shear Wave Elastography
    Edwards, Christopher
    Cavanagh, Erika
    Kumar, Sailesh
    Clifton, Vicki
    Fontanarosa, Davide
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [43] Inter-platform reproducibility of liver stiffness measured with two different point shear wave elastography techniques and 2-dimensional shear wave elastography using the comb-push technique
    Ryu, Hwaseong
    Ahn, Su Joa
    Yoon, Jeong Hee
    Lee, Jeong Min
    ULTRASONOGRAPHY, 2019, 38 (04) : 345 - 354
  • [44] SHEAR STRAIN RATE MEASUREMENT IN 2-DIMENSIONAL CHANNEL FLOW
    SUN, HJ
    QE, JY
    SOME NEW TRENDS ON FLUID MECHANICS AND THEORETICAL PHYSICS, 1993, : 383 - 385
  • [45] Noninvasive Pediatric Liver Fibrosis Measurement: Two-Dimensional Shear Wave Elastography Compared With Transient Elastography
    Tran, Lea Chantal
    Ley, Delphine
    Bourdon, Gurvan
    Coopman, Stephanie
    Lerisson, Heloise
    Tillaux, Celine
    Behal, Helene
    Gottrand, Frederic
    Aumar, Madeleine
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [46] Point Shear Wave Elastography of the Spleen in Predicting the Presence of Esophageal Varices in Cirrhosis: Liver Stiffness vs. Spleen Stiffness
    Sindhu, Nadella
    Koteshwar, Prakashini
    Shetty, Shiran
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2020, 36 (02) : 95 - 101
  • [47] Two-dimensional shear wave elastography of the pancreas: measurement success rate, repeatability, and factors affecting measurement values
    Minling Zhuo
    Xiujuan Zhang
    Yi Tang
    Yan Yan
    Zhikui Chen
    Journal of Medical Ultrasonics, 2022, 49 : 261 - 268
  • [48] Reproducibility of Anterior Scalene Stiffness Measurement with Shear Wave Elastography: An Inter-Examiner Reliability Study
    Varol, Umut
    Sanchez-Jimenez, Elena
    Valera-Calero, Juan Antonio
    Plaza-Manzano, Gustavo
    Fernandez-de-las-Penas, Cesar
    Navarro-Santana, Marcos Jose
    Sanchez-Jorge, Sandra
    Ortega-Santiago, Ricardo
    ULTRASCHALL IN DER MEDIZIN, 2024, 45 (06): : 622 - 628
  • [49] INFLUENCE OF MEASUREMENT DEPTH ON THE STIFFNESS ASSESSMENT OF HEALTHY LIVER WITH REAL-TIME SHEAR WAVE ELASTOGRAPHY
    Wang, Cong-Zhi
    Zheng, Jian
    Huang, Ze-Ping
    Xiao, Yang
    Song, Dan
    Zeng, Jie
    Zheng, Hai-Rong
    Zheng, Rong-Qin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (03): : 461 - 469
  • [50] Two-dimensional shear wave elastography of the pancreas: measurement success rate, repeatability, and factors affecting measurement values
    Zhuo, Minling
    Zhang, Xiujuan
    Tang, Yi
    Yan, Yan
    Chen, Zhikui
    JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (02) : 261 - 268