Can Location of Stiffness Measurement Impact Spleen 2-Dimensional Shear Wave Elastography Measurement?

被引:0
|
作者
Song, Jinzhen [1 ,2 ]
Li, Jiawu [2 ]
Luo, Yan [2 ]
Lu, Qiang [2 ]
机构
[1] Qingdao Univ, Affiliated Hosp, Dept Abdominal Ultrasound, Qingdao, Peoples R China
[2] Sichuan Univ, Dept Ultrasound, West China Hosp, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
关键词
spleen; ultrasonography; 2-dimensional shear wave elastography; portal hypertension; TRANSIENT ELASTOGRAPHY; PORTAL-HYPERTENSION; LIVER STIFFNESS; NONINVASIVE ASSESSMENT; ULTRASOUND; RECOMMENDATIONS; RELIABILITY; DIAGNOSIS; CIRRHOSIS; FIBROSIS;
D O I
10.1097/RUQ.0000000000000602
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultrasound-based spleen elastography is a promising surrogate to predict portal hypertension noninvasively. In contrast to defined standards for liver stiffness measurement, the standardized examination procedures for 2-dimensional (2D) shear wave elastography spleen elastography have not been established yet. The aim was to investigate the impact of location of stiffness measurement on 2D shear wave elastography spleen stiffness measurement (SSM). Patients with splenomegaly were enrolled. Both B-mode ultrasound and elastography of spleen were performed. For SSM, 3 regions were chosen for spleen measurement: lower pole region, central region, and the region between lower pole and center. Mean SSM value, success rate, and reliability predicators (standard deviation, standard deviation/mean, size of region of interest) were assessed. A total of 124 patients were included. For mean SSM value, there were no significant differences among 3 regions. Spleen stiffness measurement success rate in lower pole region, central region, and the region between them was 63.7% (79), 91.1% (113), and 78.2% (97), respectively. The success rate in the central region was significantly higher than that in the other 2 regions (P < 0.05). Reliability in the central region was also highest among the 3 regions. Location of stiffness measurement has a limited effect on SSM. Changing location of measurement will not influence mean stiffness value in spleen.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [1] Spleen Stiffness Measurement Using 2-Dimensional Shear Wave Elastography: The Predictors of Measurability and the Normal Spleen Stiffness Value
    Cho, Young Seo
    Lim, Sanghyeok
    Kim, Yongsoo
    Sohn, Joo Hyun
    Jeong, Jae Yoon
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 423 - 431
  • [2] Evaluation of liver and spleen stiffness measurement with shear wave elastography in brucellosis
    Dogan, Ferit
    Celik, Mehmet
    Cosandal, Betul Amasyali
    Turac, Burak
    Ceylan, Mehmet Resat
    Dincer, Nevin Guler
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 (03) : 1521 - 1526
  • [3] Measurement of Spleen Stiffness by Shear-Wave Elastography for Prediction of Splenomegaly Etiology
    Batur, Abdussamet
    Alagoz, Sumeyra
    Durmaz, Fatma
    Baran, Ali Irfan
    Ekinci, Omer
    ULTRASOUND QUARTERLY, 2019, 35 (02) : 153 - 156
  • [4] Spleen Stiffness Measurement by Using Shear-Wave Elastography as a Predictor of Progression to Secondary Myelofibrosis
    Ekinci, Omer
    Ozgokce, Mesut
    Turko, Ensar
    Merter, Mustafa
    ULTRASOUND QUARTERLY, 2021, 37 (02) : 149 - 154
  • [5] Reliability Indicators for 2-Dimensional Shear Wave Elastography
    O'Hara, Sandra
    Zelesco, Marilyn
    Rocke, Karen
    Stevenson, Gil
    Sun, Zhonghua
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (11) : 3065 - 3071
  • [6] Spleen stiffness measurement by shear wave elastography using acoustic radiation force impulse in predicting the etiology of splenomegaly
    Yalcin, Kadihan
    Demir, Bilge Cakar
    ABDOMINAL RADIOLOGY, 2021, 46 (02) : 609 - 615
  • [7] Spleen stiffness measurement by shear wave elastography using acoustic radiation force impulse in predicting the etiology of splenomegaly
    Kadihan Yalçın
    Bilge Çakar Demir
    Abdominal Radiology, 2021, 46 : 609 - 615
  • [8] Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers
    Aleksander Pawluś
    Marcin S. Inglot
    Kinga Szymańska
    Krzysztof Kaczorowski
    Bartosz D. Markiewicz
    Agnieszka Kaczorowska
    Jacek Gąsiorowski
    Aleksandra Szymczak
    Małgorzata Inglot
    Joanna Bladowska
    Urszula Zaleska-Dorobisz
    Abdominal Radiology, 2016, 41 : 2169 - 2174
  • [9] Shear wave elastography of the spleen: evaluation of spleen stiffness in healthy volunteers
    Pawlus, Aleksander
    Inglot, Marcin S.
    Szymanska, Kinga
    Kaczorowski, Krzysztof
    Markiewicz, Bartosz D.
    Kaczorowska, Agnieszka
    Gasiorowski, Jacek
    Szymczak, Aleksandra
    Inglot, Magorzata
    Bladowska, Joanna
    Zaleska-Dorobisz, Urszula
    ABDOMINAL RADIOLOGY, 2016, 41 (11) : 2169 - 2174
  • [10] MEASUREMENT OF LIVER STIFFNESS USING SHEAR WAVE ELASTOGRAPHY IN A RAT MODEL: FACTORS IMPACTING STIFFNESS MEASUREMENT WITH MULTIPLE- AND SINGLE-TRACKING-LOCATION TECHNIQUES
    Langdon, Jonathan H.
    Elegbe, Etana
    Gonzalez, Raul S.
    Osapoetra, Laurentius
    Ford, Tristan
    McAleavey, Stephen A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (11): : 2629 - 2639