Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure

被引:70
|
作者
Lindberg, A
Peutzfeldt, A
van Dijken, JWV [1 ]
机构
[1] Umea Univ, Sch Dent, Dept Odontol, S-90187 Umea, Sweden
[2] Publ Dent Hlth Clin, Skelleftea, Sweden
[3] Univ Copenhagen, Sch Dent, Dept Dent Mat, Copenhagen, Denmark
关键词
halogen; hardness; irradiance; LED; polymerization;
D O I
10.1007/s00784-005-0312-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study compared the depth of cure obtained with six quartz tungsten halogen and light-emitting diode curing units at different exposure times and light tip-resin composite distances. Resin composite specimens (Tetric Ceram, A3; diameter 4 mm, height 6 mm) were exposed from 0-, 3-, and 6-mm distance. The curing units (200-700 MW/cm(2)) were used for standard (20 and 40 s), pulse-delay mode (initial exposure of 3 s at 200 mW/cm(2), followed by a resting period of 3 min and a final exposure of 10 or 30 s at 600 MW/cm(2)), or soft-start curing (40 s; exponential ramping). Curing depth was determined by measurement of Wallace hardness for each half millimeter starting at 0.5 min from the top surface. For each specimen, a mean H-W value was calculated from the H-W values determined at the depths of 2.0 mm and less (0.5, 1.0, 1.5, and 2.0 min, respectively). The depth of cure for each specimen was found by determining the greatest depth before an H-W value exceeding the minimal H-W value by 25% occurred. For all curing units, an increase in exposure time led to significantly higher depth of cure. Increasing the light tip-resin composite distance significantly reduced the depth of cure. With a light tip-resin composite distance of 6 min, median values of depth of cure varied between 2.0 and 3.5 min following a 20-s (or 3+10 s) exposure and between 3.0 and 4.5 mm following a 40-s (or 3+30 s) exposure. The composite situated above the depth of cure value cured equally well with all curing units. At both exposure times, Luxomax resulted in the significantly lowest depth of cure, and Astralis 7 yielded significantly higher depth. At both exposure times, a significant linear correlation was found between the determined power densities of the curing units and the pooled depth of cure values obtained. It seems that for the resin composite tested, the recommended exposure time of 40 s per 2-mm increment may be reduced to 20 s, or that increments may be increased from 2 to 3.5 mm. It may be that the absolute values of depth of cure found are material specific, but we believe that the relationships found between curing units, between exposure times, and between light guide distances are universal.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [41] Influence of shade and light-curing distance on the degree of conversion and flexural strength of a dual-cure core build-up resin composite
    El-Askary, Farid S.
    El-Korashy, Dalia I.
    AMERICAN JOURNAL OF DENTISTRY, 2012, 25 (02): : 97 - 102
  • [42] Depth of cure of high-viscosity bulk-fill and conventional resin composites using varying irradiance exposures with a light-emitting diode curing unit
    Hasslen, Jennifer A.
    Barkmeier, Wayne W.
    Shaddy, Raymond S.
    Little, Jared R.
    JOURNAL OF ORAL SCIENCE, 2019, 61 (03) : 425 - 430
  • [43] Effect of argon laser on the degree of conversion, depth of cure, mechanical properties, and microleakage of light-cured dental composite resins
    Shata, A
    Nathanson, D
    Pober, R
    Wu, B
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 368 - 368
  • [44] Effect of Energy Density on Low-Shrinkage Composite Resins: Diode-Pumped Solid State Laser Versus Quartz-Tungsten-Halogen Light-Curing Unit
    Heo, Young-Joon
    Lee, Geun-Ho
    Park, Jeong-Kil
    Ro, Jung-Hoon
    Garcia-Godoy, Franklin
    Kim, Hyung-Il
    Kwon, Yong Hoon
    PHOTOMEDICINE AND LASER SURGERY, 2013, 31 (01) : 28 - 35
  • [45] Preparation of a light color cardanol-based curing agent and epoxy resin composite: Cure-induced phase separation and its effect on properties
    Huang, Kun
    Zhang, Yan
    Li, Mei
    Lian, Jianwei
    Yang, Xiaohua
    Xia, Jianling
    PROGRESS IN ORGANIC COATINGS, 2012, 74 (01) : 240 - 247
  • [46] Effect of Cusp Inclination and Light-curing Time on Microshear Bond Strength of a Dual-cure Self-adhesive Composite Cement to Zirconia
    Zhang, Chang-Yuan
    Yu, Hao
    Tong, Xin-Wen
    Cheng, Hui
    JOURNAL OF ADHESIVE DENTISTRY, 2018, 20 (02): : 107 - 112
  • [47] Effect of initiator concentration, exposure time and particle size of the filler upon the mechanical properties of a light-curing radiopaque dental composite
    Krishnan, VK
    Yamuna, V
    JOURNAL OF ORAL REHABILITATION, 1998, 25 (10) : 747 - 751
  • [48] The effect of curing mode of a high-power LED unit on bond strengths of dual-cure resin cements to dentin and CAD/CAM resin blocks
    Kanamori, Yuna
    Takahashi, Rena
    Nikaido, Toru
    Bamidis, Elias P.
    Burrow, Michael F.
    Tagami, Junji
    DENTAL MATERIALS JOURNAL, 2019, 38 (06) : 947 - 954
  • [49] Effect of Light-Curing Unit Type and Bulk-Fill Composite Resins with Different Photoinitiators on Marginal Gaps of Class II Restorations
    Alavi, Fereshteh Naser
    Darabi, Farideh
    Salari, Ashkan
    Dehghan, Arefeh
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2022, 22
  • [50] Effect of Light-curing Unit Design and Mouth Opening on the Polymerization of Bulk-fill Resin-based Composite Restorations in Molars
    Moreira, Rodrigo Jose
    de Deus, Raissa Albuquerque
    Hordones Ribeiro, Maria Tereza
    Lourenco Braga, Stella Sueli
    Teodoro Schettini, Ana Cecilia
    Price, Richard Bengt
    Soares, Carlos Jose
    JOURNAL OF ADHESIVE DENTISTRY, 2021, 23 (02): : 121 - 131