Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure

被引:70
|
作者
Lindberg, A
Peutzfeldt, A
van Dijken, JWV [1 ]
机构
[1] Umea Univ, Sch Dent, Dept Odontol, S-90187 Umea, Sweden
[2] Publ Dent Hlth Clin, Skelleftea, Sweden
[3] Univ Copenhagen, Sch Dent, Dept Dent Mat, Copenhagen, Denmark
关键词
halogen; hardness; irradiance; LED; polymerization;
D O I
10.1007/s00784-005-0312-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study compared the depth of cure obtained with six quartz tungsten halogen and light-emitting diode curing units at different exposure times and light tip-resin composite distances. Resin composite specimens (Tetric Ceram, A3; diameter 4 mm, height 6 mm) were exposed from 0-, 3-, and 6-mm distance. The curing units (200-700 MW/cm(2)) were used for standard (20 and 40 s), pulse-delay mode (initial exposure of 3 s at 200 mW/cm(2), followed by a resting period of 3 min and a final exposure of 10 or 30 s at 600 MW/cm(2)), or soft-start curing (40 s; exponential ramping). Curing depth was determined by measurement of Wallace hardness for each half millimeter starting at 0.5 min from the top surface. For each specimen, a mean H-W value was calculated from the H-W values determined at the depths of 2.0 mm and less (0.5, 1.0, 1.5, and 2.0 min, respectively). The depth of cure for each specimen was found by determining the greatest depth before an H-W value exceeding the minimal H-W value by 25% occurred. For all curing units, an increase in exposure time led to significantly higher depth of cure. Increasing the light tip-resin composite distance significantly reduced the depth of cure. With a light tip-resin composite distance of 6 min, median values of depth of cure varied between 2.0 and 3.5 min following a 20-s (or 3+10 s) exposure and between 3.0 and 4.5 mm following a 40-s (or 3+30 s) exposure. The composite situated above the depth of cure value cured equally well with all curing units. At both exposure times, Luxomax resulted in the significantly lowest depth of cure, and Astralis 7 yielded significantly higher depth. At both exposure times, a significant linear correlation was found between the determined power densities of the curing units and the pooled depth of cure values obtained. It seems that for the resin composite tested, the recommended exposure time of 40 s per 2-mm increment may be reduced to 20 s, or that increments may be increased from 2 to 3.5 mm. It may be that the absolute values of depth of cure found are material specific, but we believe that the relationships found between curing units, between exposure times, and between light guide distances are universal.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [1] Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure
    Anders Lindberg
    Anne Peutzfeldt
    Jan W. V. van Dijken
    Clinical Oral Investigations, 2005, 9 : 71 - 76
  • [2] Effect of LED curing light on composite resin depth of cure.
    Dialani, N
    Sung, E
    Caputo, AA
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A86 - A86
  • [3] EFFECT OF LIGHT-INTENSITY AND EXPOSURE DURATION ON CURE OF RESIN COMPOSITE
    RUEGGEBERG, FA
    CAUGHMAN, WF
    CURTIS, JW
    OPERATIVE DENTISTRY, 1994, 19 (01) : 26 - 32
  • [4] Evaluation of composite resin depth of cure photopolymerized by two light curing unit: Halogen and LED.
    Vieira, LCC
    Bernardon, JK
    Lopes, GC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 185 - 185
  • [5] The Influence of Different Light Curing Modes on the Depth of Cure of the Composite Resin
    Miljkovic, Nikola
    Dacic, Stefan
    Karuntanovic, Tamara
    Igic, Marko
    Dacic, Milica
    Dacic-Simonovic, Dragica
    ACTA FACULTATIS MEDICAE NAISSENSIS, 2018, 35 (01) : 58 - 64
  • [6] Depth of cure of composite resin with two light-curing units
    Dannheimer, MFG
    Marais, JT
    Germishuys, PJ
    Borman, JW
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1205 - 1205
  • [7] Kinetics of light-cure bracket bonding: Power density vs exposure duration
    Mavropoulos, Anestis
    Cattani-Lorente, Maria
    Krejci, Ivo
    Staudt, Christine Bettina
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) : 543 - 547
  • [8] Effect of high intensity curing lights on composite depth of cure
    Go, CS
    Bleier, RG
    Caputo, AA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 335 - 335
  • [9] Influence of exposure time and distance to light on the ability to composite light curing
    Borges, Ana
    Pitta-Lopes, Joao
    Portugal, Jaime
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2015, 56 (03): : 166 - 172
  • [10] Light emitting diode (LED) and halogen curing - Composite depth of cure.
    Mills, RW
    Jandt, KD
    Blackwell, GB
    Ashworth, SH
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1053 - 1053