An unexpected change in DXA calibration not detected by routine quality control checks

被引:9
|
作者
Blake, GM [1 ]
Preston, NG [1 ]
Patel, R [1 ]
Herd, RJM [1 ]
Fogelman, I [1 ]
机构
[1] Guys Hosp, Dept Nucl Med, London SE1 9RT, England
关键词
calibration change; dual-energy X-ray absorptiometry; longitudinal studies;
D O I
10.1007/s001980050123
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since its commercial introduction a decade ago, the technique of dual-energy X-ray absorptiometry (DXA) has been widely recognized as a useful and sensitive method of measuring changes in bone mineral density (BMD) at selected sites in the skeleton such as the spine and proximal femur. Because of their high precision and stable calibration, DXA scanners are frequently used in clinical trials to evaluate new treatments for osteoporosis. Quality assurance procedures based on regular scanning of phantoms are widely adopted in such trials, and continuity of the phantom BMD measurements is generally believed to ensure continuity in the in-vivo calibration. We report a change in calibration of a DXA scanner that occurred during a clinical trial where the calibration shift was different for the spine and femur sites and was not predicted or explained by the standard quality control procedures using phantoms. However, we show that provided patients enrolled in studies are thoroughly randomized and the statistical analysis is confined to the differences between the treated and control groups, then the effects of such calibration shifts on conclusions regarding the efficacy of treatment are considerably smaller than the random statistical errors.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] ROUTINE URINALYSIS QUALITY-CONTROL
    FREE, HM
    FREE, AH
    CLINICAL CHEMISTRY, 1972, 18 (07) : 694 - &
  • [22] QUALITY-CONTROL IN ROUTINE URINALYSIS
    FREE, HM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1972, 29 : 184 - &
  • [23] QUALITY-CONTROL IN A ROUTINE CYTOPATHOLOGY
    MURAD, T
    PRITCHETT, P
    SHAH, G
    CROFT, J
    ACTA CYTOLOGICA, 1976, 20 (06) : 582 - 583
  • [24] Assessing the suitability of a two-dimensional array for routine quality assurance checks of flatness and symmetry
    Salma Ibrahim
    Venkatakrishnan Seshadri
    Paul Charles
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1451 - 1460
  • [25] Assessing the suitability of a two-dimensional array for routine quality assurance checks of flatness and symmetry
    Ibrahim, Salma
    Seshadri, Venkatakrishnan
    Charles, Paul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (04) : 1451 - 1460
  • [26] Staying in control - Ongoing calibration and change control practices
    Busfield, JT
    VALIDATION PRACTICES FOR BIOTECHNOLOGY PRODUCTS, 1996, 1260 : 136 - 152
  • [27] Routine and change: the role of management accounting and control
    Jack, Lisa
    Mundy, Julia
    JOURNAL OF ACCOUNTING AND ORGANIZATIONAL CHANGE, 2013, 9 (02): : 112 - 118
  • [28] Baseline calibration of autobrazer for quality control
    Agba, EI
    Jones, EW
    Penaherrera, AS
    Thrift, B
    FLEXIBLE AUTOMATION AND INTELLIGENT MANUFACTURING 1996, 1996, : 110 - 119
  • [29] Baseline calibration of autobrazer for quality control
    Agba, EI
    Jones, EW
    Penaherrera, AS
    Thrift, B
    JOURNAL OF MANUFACTURING SYSTEMS, 1997, 16 (06) : 399 - 408
  • [30] CALIBRATION AND QUALITY-CONTROL MATERIALS
    STAMM, D
    ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE, 1974, 12 (04): : 137 - 145