Performance of the Lancelot Beam Position Monitor at the Diamond Light Source

被引:2
|
作者
Chagani, H. [1 ]
Garcia-Nathan, T. B. [2 ]
Jiang, C. [2 ]
Kachatkou, A. [2 ]
Marchal, J. [1 ,4 ]
Omar, D. [1 ]
Tartoni, N. [1 ]
van Silfhout, R. G. [2 ,3 ]
Williams, S. [1 ]
机构
[1] Diamond Light Source Ltd, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[2] Univ Manchester, Sackville St, Manchester M13 9PL, Lancs, England
[3] ESRF, Dutch Belgian Beamline DUBBLE, 71 Ave Martyrs, F-38043 Grenoble, France
[4] Inst Laue Langevin, 71 Ave Martyrs, F-38042 Grenoble, France
来源
关键词
Beam-line instrumentation (beam position and profile monitors; beam-intensity monitors; bunch length monitors); Image processing; X-ray detectors; SYNCHROTRON-RADIATION; DETECTOR; RESOLUTION;
D O I
10.1088/1748-0221/12/12/C12044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Lancelot beam position and profile monitor records the scattered radiation off a thin, low-density foil, which passes through a pinhole perpendicular to the path of the beam and is detected by a Medipix3RX sensor. This arrangement does not expose the detector to the direct beam at synchrotrons and results in a negligible drop in flux downstream of the module. It allows for magnified images of the beam to be acquired in real time with high signal-to-noise ratios, enabling measurements of tiny displacements in the position of the centroid of approximately 1 mu m. It also provides a means for independently measuring the photon energy of the incident monoenergetic photon beam. A constant frame rate of up to 245 Hz is achieved. The results of measurements with two Lancelot detectors installed in different environments at the Diamond Light Source are presented and their performance is discussed.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Tevatron beam position monitor upgrade
    Wolbers, S
    Banerjee, B
    Barker, B
    Bledsoe, S
    Boes, T
    Bowden, M
    Cancelo, G
    Forster, B
    Duerling, G
    Haynes, B
    Hendricks, B
    Kasza, T
    Kutschke, R
    Mahlum, R
    Martens, M
    Mengel, M
    Olson, M
    Pavlicek, V
    Pharn, T
    Piccoli, L
    Steimel, J
    Treptow, K
    Votava, M
    West, B
    Webber, R
    Zhang, D
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2616 - 2618
  • [42] RHIC beam position monitor characterization
    Brookhaven Natl Lab, Upton, United States
    Proc IEEE Part Accel Conf, 1600, (2458-2460):
  • [43] KEK BEAM POSITION MONITOR SYSTEM
    SHIBATA, S
    MUTO, K
    ISHII, H
    IGARASHI, Z
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02): : 167 - 167
  • [44] Beam position monitor with HOM couplers
    Sawamura, M
    Nagai, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 557 (01): : 328 - 330
  • [45] INTEGRATION OF BEAM POSITION MONITOR SIGNALS
    HALBACH, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03): : 531 - 531
  • [46] BEAM POSITION MONITOR FOR ACCELERATED ELECTRONS
    PRUDNIKOV, IA
    TOROPOV, AS
    NUCLEAR INSTRUMENTS & METHODS, 1971, 92 (03): : 359 - +
  • [47] A SIMPLE RADIATION BEAM POSITION MONITOR
    VOJNOVIC, B
    SEHMI, DS
    NEWMAN, RG
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09): : 1179 - 1185
  • [48] SIMPLE ACCELERATOR BEAM POSITION MONITOR
    SNOWDON, KJ
    BARBER, CH
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (10): : 923 - 923
  • [49] SENSITIVE MONITOR OF CYCLOTRON BEAM POSITION
    GOTTSCHALK, B
    STENBERG, DJ
    KOEHLER, AM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (06): : 744 - &
  • [50] SWITCHED DETECTOR FOR BEAM POSITION MONITOR
    BISCARDI, R
    BITTNER, JW
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1516 - 1518