Performance of a bench-scale membrane pilot plant for the upgrading of biogas in a wastewater treatment plant

被引:49
|
作者
Stern, SA [1 ]
Krishnakumar, B
Charati, SG
Amato, WS
Friedman, AA
Fuess, DJ
机构
[1] Syracuse Univ, Dept Chem Engn & Mat Sci, Syracuse, NY 13244 USA
[2] Syracuse Univ, Dept Civil & Environm Engn, Syracuse, NY 13244 USA
[3] Niagara Mohawk Power Corp, Syracuse, NY 13202 USA
关键词
gas separations; biogas upgrading; biogas pilot plant;
D O I
10.1016/S0376-7388(98)00238-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A bench-scale membrane pilot plant for upgrading biogas generated at a municipal wastewater treatment plant was constructed and operated for extended periods of time. The raw biogas was available at 45-60 psia (3.1-4.1 bar) and contained 62.6 mol% CH4, the balance being mainly CO2 and a large number of organic impurities. The operation of the pilot plant was tested with two identical hollow-fiber modules for periods of over 1000 h (41 days) with each module. One of the hollow-fiber modules was tested at an average pressure of about 525 psia (36 bar) and at stage-cuts of 0.34-0.41, and the other module at about 423 psia (29 bar) and at stage-cuts of 0.36-0.39. The flow rates of the biogas feed were 30-36 ft(3)/h (2.4x10(-4)-2.8 x 10(-4) m(3)/s) and 21-24 ft(3)/h (1.7 x 10(-4)-1.9 x 10(-4) m(3)/s), respectively. The CH4 concentration in the retentate stream (the upgraded biogas) was raised in these tests to 92-95 mol% CH4. The performance of the pilot plant was stable over the entire test periods. An even higher CH4 concentration of 97 mol% was reached in short-term tests at a stage-cut of 0.46. The raw biogas had to be pretreated to prevent the condensation of organic impurities which tended to dissolve the hollow fibers. Upgraded biogas containing over 90 mol% CH4 produced in a large-scale membrane separation plant could be used for the generation of electricity. At the same time, the permeate (waste) stream would contain over 15 mol% CH4 and could be used for heating applications. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 50 条
  • [41] Simulation study supporting wastewater treatment plant upgrading
    Hvala, N
    Vrecko, D
    Burica, O
    Strazar, M
    Levstek, M
    WATER SCIENCE AND TECHNOLOGY, 2002, 46 (4-5) : 325 - 332
  • [42] Performance evaluation of the bench-scale hybrid alternating aerobic/anoxic activated sludge-membrane bioreactor system for the wastewater treatment and reuse
    Park, Sangjin
    Park, Chang Min
    Kim, Do-Hyung
    DESALINATION AND WATER TREATMENT, 2018, 125 : 16 - 25
  • [43] BENCH-SCALE TESTS FOR INSITU FILTER MEDIA CLEANING AT OWOSSO, MICH, WATER TREATMENT-PLANT
    SINGHAL, AK
    MEMMER, RG
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1979, 71 (01): : 34 - 37
  • [44] UPGRADING OF A WASTEWATER TREATMENT PLANT IN A CHEMICAL FACTORY.
    Benedek, P.
    Takacs, I.
    Vallai, I.
    Water Science and Technology, 1984, 18 (01) : 75 - 82
  • [45] Performance of an integrated membrane pilot plant for wastewater reuse: case study of oil refinery plant in Indonesia
    Widiasa, I. Nyoman
    Susanto, Asteria A.
    Susanto, Heru
    DESALINATION AND WATER TREATMENT, 2014, 52 (40-42) : 7443 - 7449
  • [46] Study on Treatment of Spent Mixed Ion Exchange Resins in Bench-scale Molten Salt Oxidation Plant
    Wang Y.
    Xue Y.
    Zheng Y.
    Ma F.
    Zhang M.
    Yan Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2024, 58 (02): : 320 - 327
  • [47] Reclaiming water from a direct air capture plant using vacuum membrane distillation - A bench-scale study
    Mirza, Nouman Rafique
    Fernandes, Debra
    Li, Qiyuan
    Omar, Amr
    Zhao, Shuaifei
    Xie, Zongli
    Taylor, Robert
    Allen, Jessica
    Feron, Paul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 305
  • [48] Evaluating CO2 Capture Performance of Trisolvent MEA-BEA-AMP with Heterogeneous Catalysts in a Novel Bench-Scale Pilot Plant
    Zhang, Nan
    Shi, Huancong
    Wang, Hanyun
    Feng, Yongcheng
    Jin, Jing
    Tontiwachwuthikul, Paitoon
    Fang, Mengxiang
    ACS OMEGA, 2023, 9 (01): : 1838 - 1849
  • [49] Storage of carbon dioxide captured in a pilot-scale biogas upgrading plant by accelerated carbonation of industrial residues
    Baciocchi, Renato
    Corti, Andrea
    Costa, Giulia
    Lombardi, Lidia
    Zingaretti, Daniela
    10TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, 2011, 4 : 4985 - 4992
  • [50] Microalgae cultivation for wastewater treatment and biogas production at Moscow wastewater treatment plant
    Shchegolkova, N.
    Shurshin, K.
    Pogosyan, S.
    Voronova, E.
    Matorin, D.
    Karyakin, D.
    WATER SCIENCE AND TECHNOLOGY, 2018, 78 (01) : 69 - 80