PCC Voltage Perturbation Path Analysis and Compensation for Grid-Connected Voltage-Source Converter Under Weak Grid

被引:32
|
作者
Zhang, Xueguang [1 ]
Li, Meng [1 ]
Xu, Dianguo [1 ]
机构
[1] Harbin Inst Technol, Dept Elect Engn, Harbin 150001, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Phase locked loops; Voltage control; Power system stability; Impedance; Perturbation methods; Stability criteria; Damping; DC-bus voltage loop; phase-locked loop (PLL); stability; three-phase grid-connected converter; weak grid; PHASE-LOCKED-LOOP; VECTOR CONTROL; INPUT-ADMITTANCE; STABILITY; INVERTERS; DESIGN;
D O I
10.1109/TIE.2020.3045593
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Under weak grid condition, negative influence is brought in on system stability because the grid impedance and the grid-connected converter control system are coupled to each other. The key factor affecting the stability of the system is the perturbation of the voltage fluctuation at the point of common coupling (PCC) to the phase-locked loop (PLL) and the dc-link voltage loop. In this article, the impedance model of a three-phase grid-connected converter, including the current loop, PLL, and dc-link voltage loop in the dq frame, is adopted, because it includes coupling information of the converter and reflects the transferring relationship among grid-connected system variables. Based on the transferring relationship, this article analyzes the perturbation paths of PCC voltage and proposes the corresponding compensation methods, i.e., the PLL and dc-link voltage loop compensation terms, which are inserted into the q and d axes of the current loop controller, respectively. The impedance analysis results show that the proposed method can effectively improve the system stability. In addition, the experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed method.
引用
下载
收藏
页码:12331 / 12339
页数:9
相关论文
共 50 条
  • [31] Analysis and Dynamic Performance Improvement of Grid-Connected Voltage-Source Converters Under Unbalanced Network Conditions
    Mortazavian, Shamed
    Shabestary, Masoud M.
    Mohamed, Yasser Abdel-Rady I.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (10) : 8134 - 8149
  • [32] Singular Perturbation Model and Transient Stability Analysis of Grid-connected Converter Under Weak Grid Faults
    Zhang Z.
    Zhu D.
    Ma Y.
    Zou X.
    Hu J.
    Kang Y.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (02): : 454 - 465
  • [33] The Frequency Spectrum Analysis of Wideband Oscillations of Grid-Connected Voltage Source Converter
    Wang, Liyi
    Cai, Deyu
    SUSTAINABILITY, 2023, 15 (13)
  • [34] Analysis of small disturbance stability mechanism for grid-connected voltage source converter
    Xing G.
    Wu C.
    Chen L.
    Huang W.
    Cheng M.
    Min Y.
    Tang Y.
    Chen, Lei (chenlei08@tsinghua.edu.cn), 1600, Electric Power Automation Equipment Press (40): : 42 - 49and162
  • [35] Implementation and performance comparison of harmonic mitigation schemes for three-phase grid-connected voltage-source converter under grid voltage distortion: HiL and experimental validation
    Srita, Suparak
    Somkun, Sakda
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2023, 161
  • [36] A Closed-Loop Model for Stability Analysis of Grid-Connected Voltage-Source Converters
    Zhang, Hongyang
    Wang, Xiongfei
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 975 - 980
  • [37] Resonance suppression and quality improvement control strategy for a three-phase grid-connected voltage-source inverter under weak grid conditions
    Zhang, Zhi
    Li, Yiyun
    Zhong, Caomao
    Zhang, Zhaoyun
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [38] Design of Digital Controllers for Grid-Connected Voltage Source Converter Operating as Voltage or Current Source
    do Nascimento, Claudionor F.
    Buso, Simone
    de Souza, Wesley Angelino
    ENERGY INFORMATICS, EI.A 2023, PT II, 2024, 14468 : 257 - 273
  • [39] Calculation and Compensation of PCC Voltage Variation Using a Grid Connected Inverter of a Wind Turbine in a Weak Grid
    Im, Ji-Hoon
    Song, Seung-Ho
    INTELEC 09 - 31ST INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE, 2009, : 804 - 809
  • [40] Coordinate control of grid-connected converter based on QPSO under unbalanced grid voltage
    Liu J.
    Zhao C.-C.
    Xie Z.-H.
    Zhou F.-H.
    Kongzhi yu Juece/Control and Decision, 2021, 36 (04): : 901 - 908