Mechanomyography and electromyography force relationships during concentric, isometric and eccentric contractions

被引:130
|
作者
Madeleine, P
Bajaj, P
Sogaard, K
Arendt-Nielsen, L
机构
[1] Aalborg Univ, Ctr Sensory Motor Interact, DK-9220 Aalborg, Denmark
[2] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
关键词
electromyography; mechanomyography; isometric and anisometric contraction;
D O I
10.1016/S1050-6411(00)00044-4
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to investigate systematically if complementary knowledge could be obtained from the recordings of electromyography (EMG) and mechanomyography (MMG) signals. EMG and MMG activities were recorded from the first dorsal interosseous muscle during slow concentric, isometric, and eccentric contraction at 0, 25, 50, 75 and 100% of the maximal voluntary contraction (MVC). The combination of the EMG and MMG recordings during voluntary concentric-isometric-eccentric contraction showed significant different non-linear EMG/force and MMG/force relationships (P<0.001). The EMG root mean square (rms) values increased significantly from 0 to 50% MVC during concentric and isometric contraction and up to 75% MVC during eccentric contraction (P<0.05). The MMG rms values increased significantly from 0 to 50% MVC during concentric contraction (P<0.05). The non-linear relationships depended mainly on the type and the level of contraction together with the angular velocity. Furthermore, the type of contraction, the contraction level, and the angular velocity influenced the electromechanical efficiency evaluated as the MMC to EMG ratio (P<0.05). These results highlight that EMG and MMG provide complementary information about the electrical and mechanical activity of the muscle. Different activation strategies seem to be used during graded isometric and anisometric contraction. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [41] MOTOR UNIT BEHAVIOR DURING CONCENTRIC, ECCENTRIC AND ISOMETRIC ACTIVITIES
    ANDREWS, PD
    SODERBERG, GL
    PHYSICAL THERAPY, 1983, 63 (05): : 764 - 764
  • [42] A pilot study on the effect of oral contraceptives on electromyography and mechanomyography during isometric muscle actions
    Drake, SM
    Evetovich, T
    Eschbach, C
    Webster, M
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (03) : 297 - 301
  • [43] PERCEIVED EXERTION DURING EXERCISE WITH CONCENTRIC AND ECCENTRIC MUSCLE CONTRACTIONS
    HENRIKSSON, J
    BONDEPET.F
    KNUTTGEN, HG
    ERGONOMICS, 1972, 15 (05) : 537 - +
  • [44] BLOOD GLUCOSE KINETICS DURING CONCENTRIC AND ECCENTRIC MUSCLE CONTRACTIONS
    Taliari, Jean Donizete Silveira
    Ramos, Rogerio Rodrigo
    Ballaris, Alessandra de Lourdes
    Taliari, Matheus Alexandre da Silva
    Munin, Egberto
    BIOSCIENCE JOURNAL, 2022, 38
  • [45] Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode
    Madeleine, P
    Jorgensen, LV
    Sogaard, K
    Arendt-Nielsen, L
    Sjogaard, G
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 87 (01) : 28 - 37
  • [46] MOTOR UNIT-ACTIVITY DURING ISOMETRIC AND CONCENTRIC-ECCENTRIC CONTRACTIONS OF THE HUMAN FIRST DORSAL INTEROSSEUS MUSCLE
    HOWELL, JN
    FUGLEVAND, AJ
    WALSH, ML
    BIGLANDRITCHIE, B
    JOURNAL OF NEUROPHYSIOLOGY, 1995, 74 (02) : 901 - 904
  • [47] Neuromuscular and Isometric Force-velocity Adaptations to Concentric and Eccentric Strength Training
    Blazevich, Anthony J.
    Cannavan, Dale
    Coleman, David R.
    Wytch, Paul
    Horne, Sara
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S290 - S290
  • [48] Changes in fluctuation of isometric force following eccentric and concentric exercise of the elbow flexors
    Lavender, AP
    Nosaka, K
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (03) : 235 - 240
  • [49] Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode
    Pascal Madeleine
    Lars Jørgensen
    Karen Søgaard
    Lars Arendt-Nielsen
    Gisela Sjøgaard
    European Journal of Applied Physiology, 2002, 87 : 28 - 37
  • [50] Changes in fluctuation of isometric force following eccentric and concentric exercise of the elbow flexors
    Andrew P. Lavender
    Kazunori Nosaka
    European Journal of Applied Physiology, 2006, 96 : 235 - 240