An ion source for the HVEE 14C isotope ratio mass spectrometer for biomedical applications

被引:0
|
作者
Mous, DJW
Fokker, W
Van den Broek, R
Koopmans, R
机构
[1] High Voltage Engn Europa BV, NL-3800 AB Amersfoort, Netherlands
[2] Univ Oxford, Oxford Radiocarbon Accelerator Unit, Oxford OX1 3QJ, England
关键词
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
During the past two decades, accelerator mass spectrometry (AMS) has allowed major developments in many areas of geosciences and archaeology. In the near future, AMS should realize a similar potential in the field of biomedical research, leading ultimately to clinical applications. For such applications, the required instrument differs significantly from that presently used in the field of C-14 dating. Whereas the needed accuracy and sensitivity is more than an order of magnitude less demanding than that for present state-of-the-art C-14 instrumentation, the widespread acceptance of C-14 AMS in biomedical research will require AMS spectrometers that are small, simple to operate and capable of handling CO2 samples. In order to satisfy these demands, HVEE has developed a compact C-14 AMS spectrometer dedicated to biomedical research. The instrument consists of a compact accelerator with a footprint of 2.25 x 1.25 m and an ion source that features direct CO2 acceptance and optimal user friendliness. Having previously described the layout and design of the accelerator, we here discuss progress on the accelerator and present the design and first results of the CO2 ion source.
引用
收藏
页码:283 / 288
页数:6
相关论文
共 50 条
  • [21] An upgraded ion source for a mass spectrometer
    Zavilopulo, A. N.
    Mironets, E. A.
    Agafonova, A. S.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2012, 55 (01) : 65 - 71
  • [22] MASS SPECTROMETER WITH PULSED ION SOURCE
    AGISHEV, EI
    IONOV, NI
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1958, 3 (08): : 1638 - 1648
  • [23] AN IMPROVED MASS SPECTROMETER ION SOURCE
    SCHAEFFER, OA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1954, 25 (07): : 660 - 662
  • [24] Isotope fractionation during capillary leaking in an isotope ratio mass spectrometer
    Yan, Hao
    Peng, Yongbo
    Bao, Huiming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (11)
  • [25] A MASS SPECTROMETER FOR HIGH PRECISION ISOTOPE RATIO DETERMINATIONS
    WANLESS, RK
    THODE, HG
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1953, 30 (11): : 395 - 398
  • [26] A new negative and positive gas ion source for isotope ratio mass spectrometry
    Pienkos, Tomasz
    Halas, Stanislaw
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (11) : 964 - 968
  • [27] Forensic applications of 14C at CIRCE
    Marzaioli, F.
    Fiumano, V.
    Capano, M.
    Passariello, I.
    De Cesare, N.
    Terrasi, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (24): : 3171 - 3175
  • [28] Differential mobility spectrometry improves uranium isotope ratio measurements on an ion trap mass spectrometer
    Ayodeji, Ifeoluwa
    Keidel, Alexandra
    Perdomo, Nelson
    Shelley, Jacob
    Evans-Nguyen, Theresa
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 472
  • [29] INVESTIGATIONS INTO A POSSIBLE 14C ISOTOPE EFFECT IN PHOTODISSOCIATIONS
    SCHUTTE, L
    HAVINGA, E
    TETRAHEDRON, 1967, 23 (05) : 2281 - &
  • [30] The experimental internal bremsstrahlung spectrum of 14C isotope
    Almaz, Ekrem
    Celiktas, Cueneyt
    Aygoer, Hasan Ali
    Saritas, Turgut
    PRAMANA-JOURNAL OF PHYSICS, 2024, 98 (03):