Performance improvement of a photovoltaic-thermal system using a wavy-strip insert with and without nanofluid

被引:41
|
作者
Maadi, Seyed Reza [1 ,2 ]
Navegi, Ali [2 ]
Solomin, Evgeny [3 ]
Ahn, Ho Seon [4 ]
Wongwises, Somchai [5 ,6 ]
Mahian, Omid [1 ,7 ]
机构
[1] Xi An Jiao Tong Univ, Sch Chem Engn & Technol, Xian 710049, Shaanxi, Peoples R China
[2] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Razavi Khorasan, Iran
[3] South Ural State Univ, Dept Elect Stn Grids & Power Supply Syst, Chelyabinsk, Russia
[4] Incheon Natl Univ, Dept Mech Engn, Incheon, South Korea
[5] King Mongkuts Univ Technol Thonburi, Fac Engn, Dept Mech Engn, Bangkok 10140, Thailand
[6] Natl Sci & Technol Dev Agcy NSTDA, Pathum Thani 12120, Thailand
[7] Ferdowsi Univ Mashhad, Ctr Nano Technol Renewable Energies, Dept Mech Engn, Mashhad, Razavi Khorasan, Iran
关键词
Photovoltaic-thermal module; Wavy-strip insert; Insert flow; Computational fluid dynamics; Al2O3-Water nanofluid; PHASE-CHANGE MATERIALS; HEAT-TRANSFER CHARACTERISTICS; FLAT-PLATE COLLECTORS; LAMINAR-FLOW; PVT SYSTEM; PARAMETRIC ANALYSIS; EXERGY ANALYSIS; TWISTED TAPE; ENERGY; ENHANCEMENT;
D O I
10.1016/j.energy.2021.121190
中图分类号
O414.1 [热力学];
学科分类号
摘要
The influence of the wavy-strip insert on photovoltaic-thermal (PVT) system performance was studied. To this end, computational fluid dynamics were used to model the 3-D PVT system and wavy-strip insert. The effect of the wavy-strip insert in a given total mass flow rate was examined on different numbers of the tube (N), which is in the range of 5-25. A rise in N has a direct correlation by an increase in PVT efficiencies; meanwhile, for N > 16 based on the ASHRAE method, heat removal factor and the overall heat-loss coefficient tend to be almost constant. Moreover, the effect of the wavy-strip insert is more pronounced in a lower number of tubes, so that for N = 5, the heat removal factor improved by 18%, and the overall heat-loss coefficient reduced by 3.5%. The PV plate temperature distribution is a crucial issue that can lead to serious thermal stress and lifetime degradation. A detailed study on the PV plate temperature distribution demonstrates that using the wavy-strip insert considerably reduces the temperature gradient. For N = 16, the optimum performance of the PVT module was obtained, and hence the effect of different Reynolds numbers ranging from 600 to 1600 was examined for it. It has been found that the use of insert in considered Reynolds number range will cause the thermal and electrical efficiencies to improve by 6.92-8.64% and 2.01-2.45% compared to a typical PVT system, respectively. In entire cases, the pump power consumption compared to the PV cells' electrical output power is negligible. A comparative study on the performance improvement of this method and other commonly used methods was carried out. It has shown that this method can become competitive with other methods to improve the PVT performance; meanwhile, it can tackle with substantial problems of previous common methods. Lastly, for optimum configuration of the studied PVT system, further improvement is achieved by dispersing Al2O3 nanoparticles into the working fluid. The results elucidate that the integrated PVT system/Al2O3-water based nanofluid with a wavy-strip compared to the typical PVT system leads to improve electrical and thermal efficiencies by 3.5% and 12.06%, respectively. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Synergistic impact of tube configuration and working fluid on photovoltaic-thermal system performance
    Bhat, Amir Yousuf
    Qayoum, Adnan
    RENEWABLE ENERGY, 2023, 207 : 205 - 217
  • [42] A comparative performance evaluation and sensitivity analysis of a photovoltaic-thermal system with radiative cooling
    Ahmed, Salman
    Li, Zhenpeng
    Ma, Tao
    Javed, Muhammad Shahzad
    Yang, Hongxing
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2021, 221
  • [43] Performance Assessment of an Interconnected Photovoltaic-Thermal System and Solar Thermal Collector: Parametric Study and Optimization
    Karami, Maryam
    Heidarnejad, Parisa
    ENERGY SCIENCE & ENGINEERING, 2025,
  • [44] Experimental and numerical investigation on thermal and electrical performance of a building integrated photovoltaic-thermal collector system
    Corbin, Charles D.
    Zhai, Zhiqiang John
    ENERGY AND BUILDINGS, 2010, 42 (01) : 76 - 82
  • [45] Performance enhancement of a photovoltaic-thermal thermoelectric collector using night radiative cooling
    Zaite, Abdelkabir
    Belouaggadia, Naoual
    Abid, Cherifa
    Kaiss, Ahmed
    Imghoure, Oumaima
    APPLIED ENERGY, 2024, 364
  • [46] Research on the Performance of Solar Space Heating Systems Using Photovoltaic-Thermal Collectors
    Zhou X.
    Sui Z.
    Wang X.
    Applied Solar Energy, 2023, 59 (1) : 48 - 63
  • [47] Environmental and energy assessment of photovoltaic-thermal system combined with a reflector supported by nanofluid filter and a sustainable thermoelectric generator
    Sheikholeslami, M.
    Khalili, Z.
    Scardi, P.
    Ataollahi, N.
    JOURNAL OF CLEANER PRODUCTION, 2024, 438
  • [48] Photovoltaic-thermal system combined with wavy tubes, twisted tape inserts and a novel coolant fluid: energy and exergy analysis
    Khosravi, Koorosh
    Eisapour, Amir Hossein
    Rahbari, Alireza
    Mahdi, Jasim M.
    Talebizadehsardari, Pouyan
    Keshmiri, Amir
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2023, 17 (01)
  • [49] Energy and Exergy Analyses of Photovoltaic-Thermal (PV/T) System with TiO2/Water Nanofluid Flow
    Rukman, Nurul Shahirah Binti
    Fudholi, Ahmad
    Razali, Nur Farhana Mohd
    Ruslan, Mohd Hafidz
    Sopian, Kamaruzzaman
    INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND GREEN TECHNOLOGY 2018, 2019, 268
  • [50] Performance investigation of acetone and mobiltherm as a heat transfer medium in a hybrid photovoltaic-thermal system
    Das, Sudhansu Sekhar
    Kumar, Pramod
    Sandhu, Sarbjot Singh
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (03) : 7122 - 7135